# Structural Silicone Glazing (SSG) Bite Width Calculator

> Calculate the required structural silicone sealant bite width for a glass lite under wind load.

Page: https://craftquantities.com/calculators/materials-quantities/ssg-bite-width-calculator/ (calculator). This is the page's Markdown copy; the HTML page is the canonical version.

Version 1.1.1, sources checked 2026-09-06, 2 published test vectors.

Required silicone bite width: 0.255 in for Design Wind Load 31.33 psf, Glass Lite Short-Span Dimension 47 in and Allowable Silicone Stress 20.02 psi, the page's opening figures; on the metric page, 1.5 kPa, 1200 mm and 138 kPa give 6.52 mm. Sources are cited below.

## Inputs

A length, area or volume is entered with its unit. The page opens on the values below: a metric reader sees the metric column, a US customary reader the other.

| Input | id | Opens at (metric) | Opens at (US customary) | Accepts |
|---|---|---|---|---|
| Design Wind Load | `windLoad` | 1.5 kPa | 31.3282 psf | pa, kpa, mpa, psi, psf, in_wc; range 500–5000 Pa |
| Glass Lite Short-Span Dimension | `liteShortDimension` | 1200 mm | 47 in | mm, cm, m, in, ft, yd; range 0.01–3 m |
| Allowable Silicone Stress | `allowableStress` | 138 kPa | 20.0152 psi | pa, kpa, mpa, psi, psf, in_wc; range 100000–210000 Pa |

- **Design Wind Load**: The design wind pressure acting on the glass lite.
- **Glass Lite Short-Span Dimension**: The shorter of the glass lite's two edge dimensions.
- **Allowable Silicone Stress**: The long-term allowable tensile stress for the structural silicone sealant — the GANA consensus standard is 138 kPa (20 psi).

## The answer on the opening values

Worked exactly as the page works it, on the values each system opens on.

### Metric

| Result | Value |
|---|---|
| **Required silicone bite width** | 6.52 mm |

### US customary

| Result | Value |
|---|---|
| **Required silicone bite width** | 0.255 in |

- Confidence: medium.

## How it is worked out

This is the standard ASTM C1401/GANA tributary-load simplification (ignoring two-way plate action and aspect ratio) — a licensed structural/facade engineer should verify final bite width, especially for high-aspect-ratio lites where FEA-based methods may justify a different allowable stress.

The method, derived in full:

- [Glass, Insulating Units and the Curtain Wall](https://craftquantities.com/methodology/glazing-and-curtain-wall/): Why glass has no strength until you say how long the load lasts, why the edge of a sealed unit leaks more heat than the middle, and why a mullion's deflection limit protects the seal rather than the glass.

What this calculation does not cover:

- Bite is one of two dimensions in the joint, and only the wind-resisting one is sized here. The glueline THICKNESS — the gap between glass and frame — is what absorbs the differential movement as the metal grows and the glass does not, and practice keeps the bite to no more than about three times it, with neither dropping much below 6 mm (0.24 in) however small the arithmetic comes out. Correct bite in too thin a glueline does not fail in a storm; it tears quietly through the first hot summer.
- Nothing here carries the weight of the glass. Structural silicone's allowable stress under permanent load is a small fraction of the 138 kPa (20 psi) used for wind — of the order of 7 kPa (1 psi) — so on all but the smallest lites the dead load belongs on setting blocks, and a lite genuinely hung in sealant needs its own, far larger, calculation.
- The pressure entered should be the SUCTION peak for the lite's zone, not the positive one. The bite goes into tension when wind pulls the glass off the frame, and negative pressures at corners, parapets and the upper storeys of a tall building run well above the field figure quoted for the wall. Take the wrong line out of the wind schedule and the bite is undersized precisely where the building is worst loaded.

A professional must decide:

- Nothing here carries the weight of the glass. Structural silicone's allowable stress under permanent load is a small fraction of the 138 kPa (20 psi) used for wind — of the order of 7 kPa (1 psi) — so on all but the smallest lites the dead load belongs on setting blocks, and a lite genuinely hung in sealant needs its own, far larger, calculation.

## Sources

As the calculator cites them (sources checked 2026-09-06):

- ASTM C1401 / GANA Structural Sealant Glazing Manual: Bite = W×d / (2×Fa), where W is design wind load, d is the glass lite's short-span dimension, and Fa is the allowable silicone sealant stress — industry standard long-term allowable is 138 kPa (20 psi) per GANA consensus safety factor

A code or standard has force only where a jurisdiction has adopted it, usually with local amendments; check what is in force with the authority where you build.

## Questions answered on the page

**Why does the bite width depend on the lite's short-span dimension rather than its full perimeter?**

The ASTM C1401/GANA tributary-load method sizes the sealant bite off the shorter edge dimension, since in a two-way-spanning glass plate the shorter span carries a larger share of the wind load reaction to its supporting edge.

**Where does the 138 kPa allowable stress come from?**

138 kPa (20 psi) is the long-term allowable tensile stress commonly cited by GANA's Structural Sealant Glazing Manual for structural silicone, built on a consensus safety factor. Always confirm the exact allowable against your specific sealant's tested data.

**Is this a complete structural silicone glazing design?**

No — this is the standard simplified tributary-load bite calculation only. It ignores two-way plate action, aspect ratio effects, and dynamic/fatigue considerations, so a licensed structural or facade engineer should verify the final bite width, particularly for high-aspect-ratio lites.

## Related calculators

- [Structural Glazing Mullion Wind Load Deflection Calculator](https://craftquantities.com/calculators/materials-quantities/mullion-deflection-calculator/)
- [Curtain Wall Mullion Tributary Dead Load Calculator](https://craftquantities.com/calculators/materials-quantities/curtain-wall-mullion-load-calculator/)

## Run it from a program

- REST: `GET https://api.craftquantities.com/v1/calculate/ssg-bite-width-calculator` with each input as a query parameter, a length, area or volume with its unit; `https://api.craftquantities.com/v1/describe/ssg-bite-width-calculator` lists the inputs.
- MCP: the `calculate` tool at https://api.craftquantities.com/mcp with `slug` `ssg-bite-width-calculator`.
- Definition and test vectors: https://craftquantities.com/api/v1/calculators/ssg-bite-width-calculator.json

---
Source: https://craftquantities.com/calculators/materials-quantities/ssg-bite-width-calculator/
Craft Quantities: free to read, cite and link to; the pages are not licensed for republication. Quantities only: no prices, no design and no certification.