# Isolated Spread Footing Sizing Calculator

> Size a square isolated column footing from the column load and the site's allowable soil bearing pressure.

Page: https://craftquantities.com/calculators/materials-quantities/spread-footing-sizing-calculator/ (calculator). This is the page's Markdown copy; the HTML page is the canonical version.

Version 1.0.1, sources checked 2026-09-06, 2 published test vectors.

Recommended footing side length: 5.36 ft for Column Load 89.92 kip and Allowable Soil Bearing Pressure 3132.82 psf, the page's opening figures; on the metric page, 400 kN and 150 kPa give 1.63 m (square footing side). Sources are cited below.

## Inputs

A length, area or volume is entered with its unit. The page opens on the values below: a metric reader sees the metric column, a US customary reader the other.

| Input | id | Opens at (metric) | Opens at (US customary) | Accepts |
|---|---|---|---|---|
| Column Load | `columnLoad` | 400 kN | 89.9236 kip | n, kn, lbf, kip; range 10000–20000000 N |
| Allowable Soil Bearing Pressure | `allowableBearingPressure` | 150 kPa | 3132.82 psf | pa, kpa, mpa, psi, psf, in_wc; range 50000–1000000 Pa |

- **Column Load**: The total axial load the column transfers to the footing.
- **Allowable Soil Bearing Pressure**: The soil's allowable bearing capacity, from a geotechnical report.

## The answer on the opening values

Worked exactly as the page works it, on the values each system opens on.

### Metric

| Result | Value |
|---|---|
| **Recommended footing side length** | 1.63 m (square footing side) |
| Required footing area | 2.67 m² |

### US customary

| Result | Value |
|---|---|
| **Recommended footing side length** | 5.36 ft |
| Required footing area | 28.7 sq ft |

- Confidence: medium.

## How it is worked out

This is a preliminary sizing tool based on bearing pressure alone — final footing dimensions must also satisfy punching shear, one-way shear, and flexural (moment) checks per ACI 318, verified by a structural engineer.

The working the page shows, in order: Required footing area; then recommended footing side length.

The method, derived in full:

- [Bearing Capacity, and How a Load Spreads Into What Carries It](https://craftquantities.com/methodology/bearing-and-load-spread/): Why the allowable pressure under a footing is usually set by settlement rather than by strength, why a wider footing settles more at the same pressure, and why timber bearing is limited by the weakest direction of the grain.

What this calculation does not cover:

- SIZES THE PLAN AREA, NOTHING ELSE. This returns a side length from bearing pressure alone and says nothing about thickness, reinforcement or founding depth. Punching shear, one-way shear and flexure set the concrete and the steel, and on a heavily loaded column over strong ground those checks routinely demand more footing than bearing pressure does. It is a preliminary size, not a foundation design.
- Bearing capacity is not settlement. A footing sized exactly to the allowable pressure can still settle more than the structure will tolerate, and on a compressible clay the settlement check is usually the one that decides the size.
- Assumes the load is axial and lands in the middle of the pad. Any moment, eccentricity, uplift or lateral thrust skews the pressure under the footing — once the resultant leaves the middle third one edge lifts and the peak pressure runs far above the average used here — and those cases generally want a rectangular footing rather than the square this assumes.
- The footing's own weight, the backfill sitting on top of it and any plinth or slab above are not added to the load you enter, so the pressure actually delivered to the soil is higher than the pressure this sizes for.
- The allowable pressure you enter carries the whole geotechnical burden. It must already include its factor of safety — enter an ultimate capacity instead and you over-credit the ground by roughly a factor of three — and it must belong to the elevation you are actually founding at, not the shallow detail. Frost depth, groundwater, adjacent footings whose stress bulbs overlap, expansive or collapsible ground, and any code minimum footing size sit entirely outside this calculation, and none of it substitutes for a site geotechnical report.

A professional must decide:

- Structure: sizes, thicknesses, spans, reinforcement and bearing are a structural engineer's or the building official's decision. This is a quantity, not a design.

## Sources

As the calculator cites them (sources checked 2026-09-06):

- Standard preliminary footing sizing: required footing area = column load / allowable soil bearing pressure; assumed square, so side length = sqrt(area)

A code or standard has force only where a jurisdiction has adopted it, usually with local amendments; check what is in force with the authority where you build.

## Questions answered on the page

**Why square, not rectangular?**

A square footing is the most material-efficient shape for a purely axial (centered) column load — rectangular footings are used when site constraints or combined/eccentric loads require them.

**Does this size account for the footing's own weight?**

Not directly — for a more precise design, add the footing and backfill soil weight to the column load, or apply a small (5-10%) size increase as a simple approximation.

**Is bearing pressure the only thing that governs footing size?**

No — punching shear (the column literally punching through the footing) often governs footing thickness and can require a larger footing than bearing pressure alone, especially for heavily loaded columns on strong soil.

## Related calculators

- [Footing Soil Bearing Pressure Checker](https://craftquantities.com/calculators/materials-quantities/footing-bearing-pressure-calculator/)
- [Structural Column Pour Calculator](https://craftquantities.com/calculators/materials-quantities/structural-column-pour-calculator/)

## Run it from a program

- REST: `GET https://api.craftquantities.com/v1/calculate/spread-footing-sizing-calculator` with each input as a query parameter, a length, area or volume with its unit; `https://api.craftquantities.com/v1/describe/spread-footing-sizing-calculator` lists the inputs.
- MCP: the `calculate` tool at https://api.craftquantities.com/mcp with `slug` `spread-footing-sizing-calculator`.
- Definition and test vectors: https://craftquantities.com/api/v1/calculators/spread-footing-sizing-calculator.json

---
Source: https://craftquantities.com/calculators/materials-quantities/spread-footing-sizing-calculator/
Craft Quantities: free to read, cite and link to; the pages are not licensed for republication. Quantities only: no prices, no design and no certification.