# Soil Phase Relationships Calculator (Unit Weights and Degree of Saturation)

> From dry unit weight, water content and specific gravity: void ratio, porosity, degree of saturation, and moist, saturated and buoyant unit weights.

Page: https://craftquantities.com/calculators/materials-quantities/soil-phase-relationships-calculator/ (calculator). This is the page's Markdown copy; the HTML page is the canonical version.

Version 1.0.0, sources checked 2026-09-22, 4 published test vectors.

Moist (bulk) unit weight: 123 pcf for Dry Unit Weight 103.64 pcf, the page's opening figures; on the metric page, 16.28 kN/m³ gives 19.3 kN/m³. Sources are cited below.

## Inputs

A length, area or volume is entered with its unit. The page opens on the values below: a metric reader sees the metric column, a US customary reader the other.

| Input | id | Opens at (metric) | Opens at (US customary) | Accepts |
|---|---|---|---|---|
| Dry Unit Weight (γd) | `dryUnitWeight` | 16.28 kN/m³ | 103.637 pcf | knm3, pcf_weight; range 5–23 kN/m³ |
| Water Content (w), per cent | `waterContent` | 18.4 | 18.4 | range 0–150 |
| Specific Gravity of Solids (Gs) | `specificGravity` | 2.68 | 2.68 | range 1.5–3 |

- **Dry Unit Weight (γd)**: The weight of the solids in a unit volume of soil, from the laboratory's dry density.
- **Water Content (w), per cent**: The mass of pore water as a percentage of the mass of dry solids.
- **Specific Gravity of Solids (Gs)**: The density of the soil grains relative to water — about 2.65 to 2.70 for most mineral soils.

## The answer on the opening values

Worked exactly as the page works it, on the values each system opens on.

### Metric

| Result | Value |
|---|---|
| **Moist (bulk) unit weight** | 19.3 kN/m³ |
| Void ratio (e) | 0.61 |
| Porosity (n) | 38.08 % |
| Degree of saturation (S) | 80.19 % |
| Air voids | 7.54 % |
| Dry unit weight | 16.28 kN/m³ |
| Saturated unit weight | 20.02 kN/m³ |
| Buoyant (submerged) unit weight | 10.21 kN/m³ |

### US customary

| Result | Value |
|---|---|
| **Moist (bulk) unit weight** | 123 pcf |
| Void ratio (e) | 0.61 |
| Porosity (n) | 38.08 % |
| Degree of saturation (S) | 80.19 % |
| Air voids | 7.54 % |
| Dry unit weight | 103.64 pcf |
| Saturated unit weight | 127.42 pcf |
| Buoyant (submerged) unit weight | 64.97 pcf |

## How it is worked out

The moist figure is the weight of the ground as dug, water included — the one retained soil carries above the water table. Below the water table a wall or footing check takes the buoyant figure and carries the water separately at full pressure.

The working the page shows, in order: Void ratio (e); Porosity (n); Degree of saturation (S); Air voids; Dry unit weight; Saturated unit weight; Buoyant (submerged) unit weight; then moist (bulk) unit weight.

The method, derived in full:

- [Soil State: Void Ratio, Compaction and Consolidation](https://craftquantities.com/methodology/soil-state-and-consolidation/): Why 95% compaction is not a number until you name the test, why what a site was loaded with in the past matters more than what you are about to put on it, and why seepage roughly halves a slope's factor of safety.

What this calculation does not cover:

- The unit weight of water is fixed at 9.81 kN/m³ (62.4 pcf), which is fresh groundwater. A pore fluid that is brine, a tailings liquor or a contaminated leachate is heavier, and the saturated and buoyant figures need working with its own value.
- Phase relations describe one specimen. The dry density, the water content and the specific gravity have to come from the same sample; mixed across samples they can produce a saturation over 100 per cent, which this page reports as impossible rather than rounding it away.
- The saturated and buoyant weights assume the voids are completely full below the water table. A zone of partial saturation just above it, or gas in an organic clay, sits between the moist and saturated figures.
- It converts what the laboratory measured; it does not measure the ground. A density from a disturbed or remoulded sample describes the sample, and fill placed and compacted on site has its own figures, set by the compaction specification rather than by the natural ground beside it.

## Sources

As the calculator cites them (sources checked 2026-09-22):

- Phase relationships of a soil element of solids, water and air: void ratio e = Gs·γw/γd − 1, porosity n = e/(1 + e), degree of saturation S = w·Gs/e, moist unit weight γ = γd(1 + w), saturated unit weight γsat = (Gs + e)·γw/(1 + e) and buoyant unit weight γ′ = γsat − γw (Craig's Soil Mechanics, chapter 1; the quantities as BS 1377-2 and ASTM D7263 define them)

A code or standard has force only where a jurisdiction has adopted it, usually with local amendments; check what is in force with the authority where you build.

## Questions answered on the page

**Why does the moist unit weight matter more than the dry one?**

Because the ground in service is not oven-dry. A compaction report states dry density because that is what compaction is specified against, and carrying it into a retaining wall check as the weight of the retained soil leaves the water out of the driving load — eighteen per cent of it on a soil at 18 per cent water content. The moist figure puts it back: γ = γd × (1 + w).

**What is the buoyant unit weight, and when is it used?**

The saturated unit weight less the unit weight of water. Below the water table the grains are supported by the water they displace, so what presses down on a footing, or pushes on a wall as soil, is only a little over half the soil's weight in air. The water is not lost: it acts separately, at full hydrostatic pressure with no earth-pressure coefficient, which is why it has its own line in the check.

**Why does a degree of saturation over 100 per cent appear?**

Because the three inputs did not come from one specimen, or one is mistyped. The voids cannot hold more water than their own volume, so S = w × Gs ÷ e above one is a consistency failure in the laboratory sheet, not a property of the soil. The page reports it as impossible and marks the figures low-confidence rather than capping it at 100.

**What value of specific gravity should I use if the report does not give one?**

2.65 for sands and 2.70 for clays is the usual assumption, and it should be written on the calculation as an assumption. The phase relations are sensitive to it: on the guide's specimen, moving Gs from 2.68 to 2.65 changes the void ratio from 0.615 to 0.597 and the saturation by about one and a half points.

## Related calculators

- [Soil Void Ratio Calculator](https://craftquantities.com/calculators/materials-quantities/soil-void-ratio-calculator/)
- [Soil Unit Weight from Specific Gravity Calculator](https://craftquantities.com/calculators/materials-quantities/soil-unit-weight-specific-gravity-calculator/)
- [Basement Wall At-Rest Earth Pressure Calculator (with Groundwater)](https://craftquantities.com/calculators/materials-quantities/basement-wall-at-rest-pressure-calculator/)
- [Shallow Foundation Bearing Capacity Calculator (Vesic Factors)](https://craftquantities.com/calculators/materials-quantities/terzaghi-bearing-capacity-calculator/)

## Run it from a program

- REST: `GET https://api.craftquantities.com/v1/calculate/soil-phase-relationships-calculator` with each input as a query parameter, a length, area or volume with its unit; `https://api.craftquantities.com/v1/describe/soil-phase-relationships-calculator` lists the inputs.
- MCP: the `calculate` tool at https://api.craftquantities.com/mcp with `slug` `soil-phase-relationships-calculator`.
- Definition and test vectors: https://craftquantities.com/api/v1/calculators/soil-phase-relationships-calculator.json

---
Source: https://craftquantities.com/calculators/materials-quantities/soil-phase-relationships-calculator/
Craft Quantities: free to read, cite and link to; the pages are not licensed for republication. Quantities only: no prices, no design and no certification.