# Soakaway Storage and Half-Emptying Time Calculator (BRE 365)

> The storage a soakaway needs at the critical storm by BRE 365, set against the store you have drawn, with the time it takes to empty to half.

Page: https://craftquantities.com/calculators/materials-quantities/soakaway-storage-half-emptying-calculator/ (calculator). This is the page's Markdown copy; the HTML page is the canonical version.

Version 1.0.0, sources checked 2026-09-22, 3 published test vectors.

Storage required at the critical storm: 1.91 yd³ for Impermeable Area Drained to the Soakaway 500 sq ft, Soakaway Length 13 ft and Soakaway Width 1.5 ft, the page's opening figures; on the metric page, 46 m², 4 m and 0.5 m give 1.5 m³. Sources are cited below.

## Inputs

A length, area or volume is entered with its unit. The page opens on the values below: a metric reader sees the metric column, a US customary reader the other.

| Input | id | Opens at (metric) | Opens at (US customary) | Accepts |
|---|---|---|---|---|
| Impermeable Area Drained to the Soakaway | `impermeableArea` | 46 m² | 500 sq ft | m2, ft2, mm2, in2; range 1–5000 m² |
| Soil Infiltration Rate f | `infiltrationRate` | 11.52 mm/h | 0.453543 in/h | mm_per_h, in_per_h; range 0.01–2000 mm/h |
| Soakaway Length | `storeLength` | 4 m | 13 ft | mm, cm, m, in, ft, yd; range 0.3–50 m |
| Soakaway Width | `storeWidth` | 0.5 m | 1.5 ft | mm, cm, m, in, ft, yd; range 0.3–20 m |
| Effective Storage Depth | `storeDepth` | 1.2 m | 4 ft | mm, cm, m, in, ft, yd; range 0.3–5 m |
| Free Volume of the Fill (void ratio) | `voidRatio` | 0.95 | 0.95 | range 0.2–0.97 |
| Storm 1 Duration (minutes, 0 if unused) | `duration1` | 15 | 15 | range 0–10080 |
| Storm 1 Rainfall Depth | `depth1` | 12 mm | 0.5 in | mm, cm, m, in, ft, yd; range 0–0.5 m |
| Storm 2 Duration (minutes, 0 if unused) | `duration2` | 60 | 60 | range 0–10080 |
| Storm 2 Rainfall Depth | `depth2` | 22 mm | 0.87 in | mm, cm, m, in, ft, yd; range 0–0.5 m |
| Storm 3 Duration (minutes, 0 if unused) | `duration3` | 360 | 360 | range 0–10080 |
| Storm 3 Rainfall Depth | `depth3` | 40 mm | 1.5 in | mm, cm, m, in, ft, yd; range 0–0.5 m |
| Storm 4 Duration (minutes, 0 if unused) | `duration4` | 1440 | 1440 | range 0–10080 |
| Storm 4 Rainfall Depth | `depth4` | 65 mm | 2.5 in | mm, cm, m, in, ft, yd; range 0–0.5 m |
| Storm 5 Duration (minutes, 0 if unused) | `duration5` | 2880 | 2880 | range 0–10080 |
| Storm 5 Rainfall Depth | `depth5` | 80 mm | 3.25 in | mm, cm, m, in, ft, yd; range 0–0.5 m |
| Storm 6 Duration (minutes, 0 if unused) | `duration6` | 0 | 0 | range 0–10080 |
| Storm 6 Rainfall Depth | `depth6` | 0 mm | 0 in | mm, cm, m, in, ft, yd; range 0–0.5 m |
| Storm 7 Duration (minutes, 0 if unused) | `duration7` | 0 | 0 | range 0–10080 |
| Storm 7 Rainfall Depth | `depth7` | 0 mm | 0 in | mm, cm, m, in, ft, yd; range 0–0.5 m |
| Storm 8 Duration (minutes, 0 if unused) | `duration8` | 0 | 0 | range 0–10080 |
| Storm 8 Rainfall Depth | `depth8` | 0 mm | 0 in | mm, cm, m, in, ft, yd; range 0–0.5 m |

- **Impermeable Area Drained to the Soakaway**: The plan area of roof and paving that drains to this soakaway.
- **Soil Infiltration Rate f**: The slowest rate from the trial pit, from the soakaway infiltration rate calculator.
- **Soakaway Length**: The internal length of the store — the crate run or the stone-filled trench.
- **Soakaway Width**: The internal width of the store.
- **Effective Storage Depth**: The depth of the store below the inlet, which is the depth that can hold water.
- **Free Volume of the Fill (void ratio)**: About 0.95 for geocellular crates and about 0.30 for clean single-size stone.
- **Storm 1 Duration (minutes, 0 if unused)**: A storm duration to test, in minutes.
- **Storm 1 Rainfall Depth**: The rainfall depth for that duration at the design return period, from your site's rainfall data.
- **Storm 2 Duration (minutes, 0 if unused)**: A storm duration to test, in minutes.
- **Storm 2 Rainfall Depth**: The rainfall depth for that duration at the design return period, from your site's rainfall data.
- **Storm 3 Duration (minutes, 0 if unused)**: A storm duration to test, in minutes.
- **Storm 3 Rainfall Depth**: The rainfall depth for that duration at the design return period, from your site's rainfall data.
- **Storm 4 Duration (minutes, 0 if unused)**: A storm duration to test, in minutes.
- **Storm 4 Rainfall Depth**: The rainfall depth for that duration at the design return period, from your site's rainfall data.
- **Storm 5 Duration (minutes, 0 if unused)**: A storm duration to test, in minutes.
- **Storm 5 Rainfall Depth**: The rainfall depth for that duration at the design return period, from your site's rainfall data.
- **Storm 6 Duration (minutes, 0 if unused)**: A storm duration to test, in minutes.
- **Storm 6 Rainfall Depth**: The rainfall depth for that duration at the design return period, from your site's rainfall data.
- **Storm 7 Duration (minutes, 0 if unused)**: A storm duration to test, in minutes.
- **Storm 7 Rainfall Depth**: The rainfall depth for that duration at the design return period, from your site's rainfall data.
- **Storm 8 Duration (minutes, 0 if unused)**: A storm duration to test, in minutes.
- **Storm 8 Rainfall Depth**: The rainfall depth for that duration at the design return period, from your site's rainfall data.

## The answer on the opening values

Worked exactly as the page works it, on the values each system opens on.

### Metric

| Result | Value |
|---|---|
| **Storage required at the critical storm** | 1.5 m³ |
| Storage the store provides | 2.28 m³ |
| Critical storm duration | 1,440 min |
| Inflow over the critical storm | 2.99 m³ |
| Outflow over the critical storm | 1.49 m³ |
| Side area to half depth (base excluded) | 5.4 m² |
| Time to empty to half | 18.33 hours |
| Time the Digest asks for, at most | 24 hours |
| Plan area ÷ perimeter | 0.22 m |
| Largest plan area ÷ perimeter that half-empties in 24 hours | 0.29 m |

### US customary

| Result | Value |
|---|---|
| **Storage required at the critical storm** | 1.91 yd³ |
| Storage the store provides | 2.74 yd³ |
| Critical storm duration | 1,440 min |
| Inflow over the critical storm | 3.86 yd³ |
| Outflow over the critical storm | 1.95 yd³ |
| Side area to half depth (base excluded) | 58 sq ft |
| Time to empty to half | 16.9 hours |
| Time the Digest asks for, at most | 24 hours |
| Plan area ÷ perimeter | 0.67 ft |
| Largest plan area ÷ perimeter that half-empties in 24 hours | 0.95 ft |

- Confidence: medium.

## How it is worked out

The store as drawn holds more than the critical storm leaves behind. It empties to half within the 24 hours BRE Digest 365 asks for.

The working the page shows, in order: Storage the store provides; Critical storm duration; Inflow over the critical storm; Outflow over the critical storm; Side area to half depth (base excluded); Time to empty to half; Time the Digest asks for, at most; Plan area ÷ perimeter; Largest plan area ÷ perimeter that half-empties in 24 hours; then storage required at the critical storm.

The method, derived in full:

- [Stormwater, Runoff and the Water Balance](https://craftquantities.com/methodology/stormwater-and-water-balance/): Why a small catchment is designed for a more intense rainfall than a large one, why a detention basin can make things worse downstream, and why a rainwater tank delivers far less than annual rainfall times roof area.

What this calculation does not cover:

- The rainfall depths belong to the site and to the approving authority's design standard — return period, climate-change allowance — and none of the defaults on this page is data for any location.
- The store is taken as a rectangle with vertical sides, emptying through its sides only; the base is written off because it silts up. A soakaway ring, a sloping-sided pit or a store with a sealed side needs its own side area.
- The half-emptying time is worked on the storage the store provides, full to its effective depth. A store that is only part-filled by the design storm empties the same fraction in the same time, because the side area and the stored volume fall together.
- A soakaway is an infiltration device, and it is only the right answer where the ground takes water, the water table stays below it, and it is far enough from buildings and boundaries; building control and the Building Regulations' drainage guidance settle those before the arithmetic starts.

## Sources

As the calculator cites them (sources checked 2026-09-22):

- BRE Digest 365 Soakaway design: inflow I = impermeable area × rainfall depth for each storm duration D; outflow O = as50 × f × D, where as50 is the internal surface area of the soakaway to 50% of its effective storage depth, excluding the base; the storage required is the largest I − O over the durations tested; the time to half empty ts50 = 0.5 × storage volume ÷ (as50 × f), usually required within 24 hours

A code or standard has force only where a jurisdiction has adopted it, usually with local amendments; check what is in force with the authority where you build.

## Questions answered on the page

**Why is the critical storm not the one-hour storm?**

Because inflow rises quickly and then flattens as the duration grows, while outflow through the sides grows in a straight line for as long as the storm lasts. On fast-draining sand outflow catches up quickly and a short, violent storm governs; on slow clay it does not catch up for most of a day. On the guide's plot the 24-hour storm needs 1.50 m³ (53 ft³) of storage where the one-hour storm needs 0.95 m³ (34 ft³).

**Why must it empty to half within 24 hours?**

So that it has room for the next storm. A soakaway that holds the design storm but is still half full days later is not available when the rain returns, and BRE Digest 365 asks that half the stored volume drains within 24 hours for that reason.

**Why does making the soakaway deeper not help it empty?**

Because the stored volume and the side area it drains through both grow with depth, so depth cancels out: the time to empty to half is plan area over perimeter, times the void ratio, divided by f. Only the shape changes it. On the guide's plot a compact box 2.0 m by 1.2 m (6 ft 7 in by 3 ft 11 in) took 30.9 hours and a trench 4.0 m by 0.5 m (13 ft 1 in by 1 ft 8 in), with fewer crates, took 18.3 hours.

**Crates or stone?**

Geocellular crates are about 95 per cent space and clean single-size stone about 30 per cent, so the same storage takes roughly three times the excavation in stone. The shape rule favours stone, though: the largest plan area over perimeter that still half-empties in time grows as the void ratio falls, so a stone trench can be wider than a crate run on the same ground.

## Related calculators

- [Soakaway Infiltration Rate Calculator (BRE 365 Trial Pit)](https://craftquantities.com/calculators/materials-quantities/soakaway-infiltration-rate-calculator/)
- [Permeable Reservoir Drawdown Time Calculator](https://craftquantities.com/calculators/sustainability-compliance/reservoir-drawdown-time-calculator/)
- [PICP Permeable Pavement Infiltration Storage Calculator](https://craftquantities.com/calculators/sustainability-compliance/picp-infiltration-storage-calculator/)
- [Rain Barrel and Rainwater Collection Calculator](https://craftquantities.com/calculators/plumbing-hvac/rain-barrel-collection-calculator/)

## Run it from a program

- REST: `GET https://api.craftquantities.com/v1/calculate/soakaway-storage-half-emptying-calculator` with each input as a query parameter, a length, area or volume with its unit; `https://api.craftquantities.com/v1/describe/soakaway-storage-half-emptying-calculator` lists the inputs.
- MCP: the `calculate` tool at https://api.craftquantities.com/mcp with `slug` `soakaway-storage-half-emptying-calculator`.
- Definition and test vectors: https://craftquantities.com/api/v1/calculators/soakaway-storage-half-emptying-calculator.json

---
Source: https://craftquantities.com/calculators/materials-quantities/soakaway-storage-half-emptying-calculator/
Craft Quantities: free to read, cite and link to; the pages are not licensed for republication. Quantities only: no prices, no design and no certification.