# Skylight Rough Opening Calculator

> Calculate the framed rough opening dimensions for a skylight from the unit size and manufacturer clearance.

Page: https://craftquantities.com/calculators/materials-quantities/skylight-rough-opening-calculator/ (calculator). This is the page's Markdown copy; the HTML page is the canonical version.

Version 1.0.1, sources checked 2026-09-05, 2 published test vectors.

Rough opening width: 2.08 ft for Skylight Unit Width 2 ft, Skylight Unit Height 3 ft and Clearance per Side 0.5 in, the page's opening figures; on the metric page, 0.6 m, 0.9 m and 13 mm give 0.626 m. Sources are cited below.

## Inputs

A length, area or volume is entered with its unit. The page opens on the values below: a metric reader sees the metric column, a US customary reader the other.

| Input | id | Opens at (metric) | Opens at (US customary) | Accepts |
|---|---|---|---|---|
| Skylight Unit Width | `skylightWidth` | 0.6 m | 2 ft | mm, cm, m, in, ft, yd; range 0.01–2 m |
| Skylight Unit Height | `skylightHeight` | 0.9 m | 3 ft | mm, cm, m, in, ft, yd; range 0.01–2.5 m |
| Clearance per Side | `clearance` | 13 mm | 0.5 in | mm, cm, m, in, ft, yd; range 0.006–0.025 m |
| Rafter Spacing, On Centres | `rafterSpacing` | 0.6 m | 2 ft | mm, cm, m, in, ft, yd; range 0.3–1.5 m |
| Rafter Thickness | `rafterThickness` | 38 mm | 1.5 in | mm, cm, m, in, ft, yd; range 0.02–0.1 m |

- **Skylight Unit Width**: The manufactured width of the skylight unit itself.
- **Skylight Unit Height**: The manufactured height of the skylight unit itself.
- **Clearance per Side**: The manufacturer's required installation clearance on each side of the unit.
- **Rafter Spacing, On Centres**: The centre-to-centre spacing of the rafters the opening is being cut through.
- **Rafter Thickness**: The thickness of one rafter, measured across the face the opening runs past.

## The answer on the opening values

Worked exactly as the page works it, on the values each system opens on.

### Metric

| Result | Value |
|---|---|
| **Rough opening width** | 0.626 m |
| Rough opening height | 0.93 m |
| Clear gap between two rafters | 0.56 m |
| Widest unit that misses the rafters | 0.54 m |
| Rafters interrupted, at fewest | 1 |
| Rafters interrupted, at most | 2 |

### US customary

| Result | Value |
|---|---|
| **Rough opening width** | 2.08 ft |
| Rough opening height | 3.08 ft |
| Clear gap between two rafters | 1.87 ft |
| Widest unit that misses the rafters | 1.79 ft |
| Rafters interrupted, at fewest | 1 |
| Rafters interrupted, at most | 2 |

## How it is worked out

The working the page shows, in order: Rough opening height; Clear gap between two rafters; Widest unit that misses the rafters; Rafters interrupted, at fewest; Rafters interrupted, at most; then rough opening width.

The method, derived in full:

- [Glass, Insulating Units and the Curtain Wall](https://craftquantities.com/methodology/glazing-and-curtain-wall/): Why glass has no strength until you say how long the load lasts, why the edge of a sealed unit leaks more heat than the middle, and why a mullion's deflection limit protects the seal rather than the glass.

What this calculation does not cover:

- The single clearance figure is added twice to each dimension, so the same gap is assumed at both jambs and at the head and sill alike; a unit whose instructions ask for more room at the head than down the sides needs two passes and the two answers read off separately.
- The rafter count says how many members the opening interrupts, not what to do about them. Every cut rafter wants a header across the opening at the head and the foot, the rafters each side of it doubled to carry those headers, and the whole of that sized by somebody for the load it now takes, because a trimmed opening is a short beam and nothing on this page sizes one.
- Where the opening lands across the roof is not asked, which is why the rafter count comes back as a range rather than a figure. The same opening slid half a bay either way can catch one more rafter or one fewer, and on a roof where the setting out has already been disturbed by a valley or a chimney the bays are not equal anyway. Mark the rafters before ordering the unit, not after.
- No pitch term enters either sum. Both dimensions are taken as lying in the plane of the roof, so an up-slope measurement lifted off a plan-view drawing will set the opening out short.
- The input ranges cap the clearance between 6 mm and 25 mm, roughly a quarter-inch to an inch per side, and the unit itself at 2 m wide by 2.5 m high, which puts oversized rooflights and any unusually generous shimming gap outside what can be entered.
- The answer comes back as the exact sum rather than a dimension anyone would mark on a rafter, and the direction of any rounding is left to you — a surplus millimetre can be shimmed out, whereas an opening rounded down has to be cut again.

## Sources

As the calculator cites them (sources checked 2026-09-05):

- Rough opening dimension = skylight unit dimension + 2 x manufacturer-specified installation clearance (commonly 0.5in / 13mm per side)
- Clear gap between two rafters = spacing on centres - rafter thickness, so the widest unit that misses the rafters entirely is that gap less twice the clearance
- A rafter is interrupted when its own thickness overlaps the opening, so the rafter centres that fall in an open span of (opening width + rafter thickness) are the ones cut: either ceil(span / spacing) - 1 or ceil(span / spacing) of them, depending where the opening lands

A code or standard has force only where a jurisdiction has adopted it, usually with local amendments; check what is in force with the authority where you build.

## Questions answered on the page

**Why is the opening bigger than the skylight?**

Because a rough opening is a framing dimension, not a product one. It is sized to the unit's outside frame plus the clearance the maker asks for so the unit can be squared, shimmed and fixed without being forced — force a skylight into a tight opening and you rack the frame, which is how a brand-new unit ends up with a seal that leaks at one corner. The number that matters more than the clearance, though, is where the opening LANDS. A skylight between two rafters costs nothing structurally; one that crosses a rafter means cutting it and heading the ends, which turns a trimming job into a structural one and often decides the size of unit actually bought. Measure the rafter spacing before choosing a skylight, not afterwards.

**Will the skylight fit between two rafters without cutting one?**

Almost never, at the spacings roofs are framed at. Take the rafter spacing, subtract one rafter thickness for the clear gap, then subtract the clearance twice: 600 mm centres on a 38 mm rafter leave a 562 mm gap and room for a 536 mm unit, and 400 mm centres leave 342 mm. The smallest rooflights sold are wider than either, so on a normally framed roof the answer is no, and the rows above say how many rafters the unit you are looking at would interrupt.

**Should I use the same clearance for width and height?**

This calculator applies the same clearance value to both dimensions, which matches most manufacturers' installation instructions — but always check your specific unit's spec sheet in case it calls for different clearances per side.

**Does this account for curb-mounted skylights?**

No — this calculates the rough opening for the skylight unit itself. A curb-mounted skylight also needs a separate curb sized per the manufacturer's curb detail, which is not covered here.

## Related calculators

- [Dormer Rafter Length Calculator](https://craftquantities.com/calculators/materials-quantities/dormer-rafter-length-calculator/)
- [Roof Cricket (Saddle) Framing Calculator](https://craftquantities.com/calculators/materials-quantities/roof-cricket-framing-calculator/)

## Run it from a program

- REST: `GET https://api.craftquantities.com/v1/calculate/skylight-rough-opening-calculator` with each input as a query parameter, a length, area or volume with its unit; `https://api.craftquantities.com/v1/describe/skylight-rough-opening-calculator` lists the inputs.
- MCP: the `calculate` tool at https://api.craftquantities.com/mcp with `slug` `skylight-rough-opening-calculator`.
- Definition and test vectors: https://craftquantities.com/api/v1/calculators/skylight-rough-opening-calculator.json

---
Source: https://craftquantities.com/calculators/materials-quantities/skylight-rough-opening-calculator/
Craft Quantities: free to read, cite and link to; the pages are not licensed for republication. Quantities only: no prices, no design and no certification.