# Ship's Ladder and Alternating Tread Stair Calculator (Loft and Attic Stairs: Risers, Pitch and Stringers)

> A ship's ladder or alternating tread stair from your rise and pitch or run: risers, going, tread overlap, housed stringers and the opening above.

Page: https://craftquantities.com/calculators/materials-quantities/ship-ladder-calculator/ (calculator). This is the page's Markdown copy; the HTML page is the canonical version.

Version 1.0.0, sources checked 2026-11-13, 5 published test vectors.

Risers: 12 risers for Total Rise 8.5 ft and Riser You Are Aiming For 8.75 in, the page's opening figures; on the metric page, 2.6 m and 220 mm give 12 risers. Source: US.

## Inputs

A length, area or volume is entered with its unit. The page opens on the values below: a metric reader sees the metric column, a US customary reader the other.

| Input | id | Opens at (metric) | Opens at (US customary) | Accepts |
|---|---|---|---|---|
| Kind | `ladderKind` | Ship's ladder (full-width treads) | Ship's ladder (full-width treads) | `ship`, `alternating` |
| Total Rise (floor to floor) | `totalRise` | 2.6 m | 8.5 ft | mm, cm, m, in, ft, yd; range 0.3–8 m |
| Riser You Are Aiming For | `targetRiser` | 220 mm | 8.75 in | mm, cm, m, in, ft, yd; range 0.1–0.3 m |
| Set by | `layoutMode` | The pitch | The pitch | `angle`, `run` |
| Pitch (°) | `pitch` | 58 | 58 | range 35–80 |
| Run available | `availableRun` | 1.4 m | 4.5 ft | mm, cm, m, in, ft, yd; range 0.3–6 m |
| Tread depth (front to back) | `treadDepth` | 220 mm | 8.75 in | mm, cm, m, in, ft, yd; range 0.08–0.35 m |
| Tread thickness | `treadThickness` | 32 mm | 1.25 in | mm, cm, m, in, ft, yd; range 0.015–0.06 m |
| Width between the stringers | `stairWidth` | 0.6 m | 2 ft | mm, cm, m, in, ft, yd; range 0.35–1.2 m |
| Paddle width | `paddleWidth` | 300 mm | 11.75 in | mm, cm, m, in, ft, yd; range 0.15–0.6 m |
| Stringer board depth | `stringerDepth` | 250 mm | 9.75 in | mm, cm, m, in, ft, yd; range 0.12–0.4 m |
| Margin above the nosings | `margin` | 20 mm | 0.75 in | mm, cm, m, in, ft, yd; range 0–0.1 m |
| Floor depth at the opening | `floorDepth` | 250 mm | 9.75 in | mm, cm, m, in, ft, yd; range 0–0.6 m |
| Headroom to keep | `headroom` | 2 m | 79 in | mm, cm, m, in, ft, yd; range 1.5–2.5 m |
| Code for the readout | `buildingCode` | US — IRC | US — IRC | `irc`, `uk`, `au`, `ca`, `generic` |

- **Kind**: Full treads, or paddles that alternate sides.
- **Total Rise (floor to floor)**: Finished floor below to finished floor above.
- **Riser You Are Aiming For**: The rise per step you want.
- **Set by**: A pitch, or the floor space the ladder may take.
- **Pitch (°)**: The angle of the pitch line from the floor.
- **Run available**: Floor space along the ladder, lower floor to the upper floor's edge.
- **Tread depth (front to back)**: The tread board's own depth.
- **Tread thickness**: Sets each trench's width.
- **Width between the stringers**: Clear between the stringers.
- **Paddle width**: One alternating tread's width.
- **Stringer board depth**: Your board; never recommended here.
- **Margin above the nosings**: Stringer top edge to the pitch line, square to it.
- **Floor depth at the opening**: Upper floor to the ceiling below.
- **Headroom to keep**: Clear height over the pitch line.
- **Code for the readout**: The code the riser, going, treads and width are read against.

`pitch` applies only when `layoutMode` is `angle`.
`availableRun` applies only when `layoutMode` is `run`.
`paddleWidth` applies only when `ladderKind` is `alternating`.

## The answer on the opening values

Worked exactly as the page works it, on the values each system opens on.

### Metric

| Result | Value |
|---|---|
| **Risers** | 12 risers |
| Riser height | 216.67 mm |
| Going, nosing to nosing | 135.39 mm |
| Pitch | 58 ° |
| Treads | 11 treads |
| Tread overlap under the one above | 84.61 mm |
| Same-foot going (alternating) | 135.39 mm |
| Run, floor to the upper floor's edge | 1.62 m |
| Stringer board length | 3.11 m |
| Trench to trench along the stringer | 255.49 mm |
| Throat under the trenches | 26.47 mm |
| Opening in the floor above | 1.41 m |
| Handrail each side | 3.07 m |

### US customary

| Result | Value |
|---|---|
| **Risers** | 12 risers |
| Riser height | 8.5 in |
| Going, nosing to nosing | 5.31 in |
| Pitch | 58 ° |
| Treads | 11 treads |
| Tread overlap under the one above | 3.44 in |
| Same-foot going (alternating) | 5.31 in |
| Run, floor to the upper floor's edge | 5.31 ft |
| Stringer board length | 10.16 ft |
| Trench to trench along the stringer | 10.02 in |
| Throat under the trenches | 0.92 in |
| Opening in the floor above | 4.62 ft |
| Handrail each side | 10.02 ft |

## How it is worked out

WITHIN THE LIMITS CHECKED — riser 217 mm (8.53 in), going 135 mm (5.33 in), tread 220 mm (8.66 in) deep, 58.0° pitch, 600 mm (23.62 in) between the stringers, inside the figures this page reads for IRC R311.7.12. Limits checked, not an approval. A ship's ladder is not an element of a means of egress under the IRC, and takes a handrail on both sides.

The working the page shows, in order: Riser height; Going, nosing to nosing; Pitch; Treads; Tread overlap under the one above; Same-foot going (alternating); Run, floor to the upper floor's edge; Stringer board length; Trench to trench along the stringer; Throat under the trenches; Opening in the floor above; Handrail each side; then risers.

The method, derived in full:

- [Stair Geometry, Ramps and Guarding](https://craftquantities.com/methodology/stair-geometry-and-guarding/): Why you choose the number of risers rather than their height, why the spread across a whole flight is held to three-eighths of an inch, and why a cable railing has to be checked deflected rather than at rest.

What this calculation does not cover:

- This lays a steep stair out; it does not approve one, and it cannot say whether your building may have one at all: that is your building official's or building control's call.
- The stringer board is your figure: its depth sets the throat shown, and whether it spans from floor to head with its fixings is your engineer's or the maker's to determine.
- Where either may be used is the code's first rule: neither is an element of a means of egress under the IRC, and Approved Document K allows them only in a loft conversion of one habitable room with too little room for a stair. Check the use before the geometry.
- Treads are housed in the stringers; a ladder on brackets or cleats sets out the same marks but has no trenches. The handrails' brackets and the fixings at the head and foot are the maker's.
- The Australian and Canadian codes' figures for these stairs are not read here.

A professional must decide:

- This lays a steep stair out; it does not approve one, and it cannot say whether your building may have one at all: that is your building official's or building control's call.
- The stringer board is your figure: its depth sets the throat shown, and whether it spans from floor to head with its fixings is your engineer's or the maker's to determine.
- Structure: sizes, thicknesses, spans, reinforcement and bearing are a structural engineer's or the building official's decision. This is a quantity, not a design.

## Sources

As the calculator cites them (sources checked 2026-11-13):

- US: IRC R311.7.11 and R311.7.12 — alternating tread devices and ship's ladders not an element of a means of egress, the clear width at and below the handrails at least 20 in (508 mm); R311.7.11.1 and R311.7.12.1 — tread depth at least 5 in, tread depth plus nosing projection at least 8 1/2 in, riser at most 9 1/2 in, an alternating tread at least 7 in wide; handrails on both sides <https://lawfilesext.leg.wa.gov/Law/WAC/WAC%20%2051%20%20TITLE/WAC%20%2051%20-%2051%20%20CHAPTER/WAC%20%2051%20-%2051%20-0311.htm>
- UK: Approved Document K (2013 edition), 1.29–1.30 and Diagram 1.10 — alternating tread stairs only in a loft conversion serving one habitable room, uniform steps with parallel nosings, slip-resistant treads, handrails both sides, rise at most 220 mm, going at least 220 mm measured between alternate nosings, 2 m headroom; 1.32 — a fixed ladder with handrails both sides only for a loft conversion of one habitable room <https://assets.publishing.service.gov.uk/media/60d5bdcde90e07716f516cfd/Approved_Document_K.pdf>
- Going = riser / tan(pitch); trench spacing along the stringer = sqrt(going^2 + riser^2); the opening in the floor above = (headroom + floor depth) x going / riser, as this site's stair stringer page works it

The site's pages for the documents these name:

- [International Residential Code](https://craftquantities.com/standards/icc/irc/)
- [Approved Documents to the Building Regulations (England)](https://craftquantities.com/standards/uk-gov/uk-approved-documents/)

A code or standard has force only where a jurisdiction has adopted it, usually with local amendments; check what is in force with the authority where you build.

## Questions answered on the page

**How steep can a ship's ladder be?**

The IRC sets no angle for a ship's ladder; it sets the parts: a going of at least 5 in, a tread with its nosing projection of at least 8 1/2 in and a riser of at most 9 1/2 in. Those two meet at about 62°, so a steeper ladder needs a shorter riser.

**How is the going of an alternating tread stair measured?**

Between alternate nosings, the step each foot takes on its own side: twice the going between consecutive treads. Approved Document K asks at least 220 mm there, with a rise of at most 220 mm.

**Can a loft be reached by a ship's ladder?**

Under the IRC neither a ship's ladder nor an alternating tread device can be an element of a means of egress. In England Approved Document K allows an alternating tread stair or a fixed ladder only in a loft conversion of one habitable room where a stair will not fit.

## Related calculators

- [Stair Rise & Run Calculator](https://craftquantities.com/calculators/renovation-construction/stair-calculator/)
- [Extension Ladder Size Calculator](https://craftquantities.com/calculators/auto-utility/extension-ladder-height-calculator/)
- [Housed Stringer Calculator (Closed String Staircase: Trenches, Wedges and String Length)](https://craftquantities.com/calculators/materials-quantities/housed-stringer-calculator/)
- [Spiral Staircase Calculator (Spiral, Helical and Curved Stairs: Treads, Going, Headroom and Handrail)](https://craftquantities.com/calculators/materials-quantities/spiral-staircase-calculator/)

## Run it from a program

- REST: `GET https://api.craftquantities.com/v1/calculate/ship-ladder-calculator` with each input as a query parameter, a length, area or volume with its unit; `https://api.craftquantities.com/v1/describe/ship-ladder-calculator` lists the inputs.
- MCP: the `calculate` tool at https://api.craftquantities.com/mcp with `slug` `ship-ladder-calculator`.
- Definition and test vectors: https://craftquantities.com/api/v1/calculators/ship-ladder-calculator.json

---
Source: https://craftquantities.com/calculators/materials-quantities/ship-ladder-calculator/
Craft Quantities: free to read, cite and link to; the pages are not licensed for republication. Quantities only: no prices, no design and no certification.