# Foundation Sheet Drain Drainage Rate Calculator

> Calculate the total drainage flow capacity of a dimpled sheet drain across a foundation wall's width.

Page: https://craftquantities.com/calculators/materials-quantities/sheet-drain-rate-calculator/ (calculator). This is the page's Markdown copy; the HTML page is the canonical version.

Version 1.0.1, sources checked 2026-09-06, 2 published test vectors.

Total drainage capacity: 213 CFM for Total Drainage Width 66 ft, the page's opening figures; on the metric page, 20 m gives 100 L/s. Sources are cited below.

## Inputs

A length, area or volume is entered with its unit. The page opens on the values below: a metric reader sees the metric column, a US customary reader the other.

| Input | id | Opens at (metric) | Opens at (US customary) | Accepts |
|---|---|---|---|---|
| Rated Flow Capacity per Meter (L/s per m) | `ratedCapacity` | 5 | 5 | range 1–15 |
| Total Drainage Width | `drainageWidth` | 20 m | 66 ft | mm, cm, m, in, ft, yd; range 0.01–200 m |

- **Rated Flow Capacity per Meter (L/s per m)**: The drainage product's rated flow capacity per unit width, from the manufacturer's data sheet.
- **Total Drainage Width**: The total width of foundation wall covered by the sheet drain.

## The answer on the opening values

Worked exactly as the page works it, on the values each system opens on.

### Metric

| Result | Value |
|---|---|
| **Total drainage capacity** | 100 L/s |

### US customary

| Result | Value |
|---|---|
| **Total drainage capacity** | 213 CFM |

- Confidence: medium.

## How it is worked out

Rated flow capacity varies by product and compressive load condition (capacity typically decreases under soil/backfill load) — use your specific sheet drain product's rated capacity under expected field loading, not an uncompressed lab value.

The method, derived in full:

- [Seepage, Drawdown and Dewatering](https://craftquantities.com/methodology/seepage-and-dewatering/): Why permeability varies over ten orders of magnitude and therefore dominates every seepage answer, why the radius of influence is an empirical fudge rather than a measurement, and why dewatering settles the neighbours.

What this calculation does not cover:

- This is the supply side only. A capacity means nothing until it is set against the flow that actually arrives at the wall, and that comes from the catchment above and around the excavation, the permeability of the backfill and the natural soil behind it, and the design storm — none of which appear on this page. A drain rated at three times the flow it will ever see and one rated at a tenth of it return the same confident number here.
- Rated flow assumes the drain stays open, and what keeps it open is the filter fabric. Fines migrating out of the backfill blind the geotextile over years, and once it blinds, the core behind it is dry and useless whatever the lab rating says. The fabric's opening size has to be matched to the actual backfill gradation — a silty or fine sand backfill against the wrong fabric is the usual way a drainage plane stops draining.
- Capacity assumes an unbroken path in and out. The sheet has to start at the footing drain and run continuously up to near grade, with the top terminated so surface water and soil cannot get in behind the fabric, and every joint lapped in the direction of flow. A plane stopped short of the footing, or one torn during backfill, delivers a fraction of this figure regardless of what the product is rated at.

A professional must decide:

- Water: supply and drainage design, and work on them, are for a licensed plumber under the local plumbing rules.

## Sources

As the calculator cites them (sources checked 2026-09-06):

- Total drainage capacity = the drain product's rated flow capacity per unit width × total drainage width, the standard method for scaling a manufacturer's per-unit-width flow rating to a full installation

A code or standard has force only where a jurisdiction has adopted it, usually with local amendments; check what is in force with the authority where you build.

## Questions answered on the page

**Why does total drainage capacity scale directly with width?**

A dimpled sheet drain's rated flow capacity is expressed per unit width because the dimpled core channels water vertically down the drainage plane — laying more width side by side simply adds parallel drainage channels, so total capacity scales linearly with the total width installed.

**Why does the rated capacity depend on compressive load?**

Backfill and soil pressure compress the dimpled core, reducing the open channel height available for water to flow through. Manufacturers typically publish flow capacity at one or more compressive load conditions — always use the figure that matches your expected backfill depth and soil load, not an unloaded lab rating.

**Does this account for the drain's connection to a footing drain or sump?**

No — this only estimates the sheet drain's own flow capacity across the given width. The downstream footing drain, collector pipe, or sump pump must also be sized to handle this flow rate without becoming the bottleneck.

## Related calculators

- [French Drain Gravel Calculator](https://craftquantities.com/calculators/auto-utility/french-drain-calculator/)
- [Perimeter Weeping Tile Pipe Segment Calculator](https://craftquantities.com/calculators/materials-quantities/weeping-tile-segment-calculator/)

## Run it from a program

- REST: `GET https://api.craftquantities.com/v1/calculate/sheet-drain-rate-calculator` with each input as a query parameter, a length, area or volume with its unit; `https://api.craftquantities.com/v1/describe/sheet-drain-rate-calculator` lists the inputs.
- MCP: the `calculate` tool at https://api.craftquantities.com/mcp with `slug` `sheet-drain-rate-calculator`.
- Definition and test vectors: https://craftquantities.com/api/v1/calculators/sheet-drain-rate-calculator.json

---
Source: https://craftquantities.com/calculators/materials-quantities/sheet-drain-rate-calculator/
Craft Quantities: free to read, cite and link to; the pages are not licensed for republication. Quantities only: no prices, no design and no certification.