# Shaftwall Track & Stud Screw Count Calculator

> Calculate total self-tapping screws for a shaftwall stud run, from the fastening schedule your tested assembly actually specifies.

Page: https://craftquantities.com/calculators/materials-quantities/shaftwall-screw-count-calculator/ (calculator). This is the page's Markdown copy; the HTML page is the canonical version.

Version 1.0.1, sources checked 2026-09-06, 2 published test vectors.

Total screws needed: 72 screws for Number of Studs 18 and Screws per Stud 4, the page's opening figures. Sources are cited below.

## Inputs

A length, area or volume is entered with its unit. The page opens on the values below: a metric reader sees the metric column, a US customary reader the other.

| Input | id | Opens at (metric) | Opens at (US customary) | Accepts |
|---|---|---|---|---|
| Number of Studs | `studCount` | 18 | 18 | range 1–500 |
| Screws per Stud (per the project fastening schedule) | `screwsPerStud` | 4 | 4 | range 2–8 |

- **Number of Studs**: The total number of shaftwall studs in the run.
- **Screws per Stud (per the project fastening schedule)**: How many screws fasten each stud to the track. Take it from the fastening schedule for your tested assembly rather than assuming both ends: many shaftwall listings leave the stud unfastened at the head so the deflection track can move, in which case only the bottom connection is counted.

## The answer on the opening values

Worked exactly as the page works it, on the values each system opens on.

### Metric

| Result | Value |
|---|---|
| **Total screws needed** | 72 screws |

### US customary

| Result | Value |
|---|---|
| **Total screws needed** | 72 screws |

## How it is worked out

The method, derived in full:

- [Fastener Schedules, Supports and Counting Over a Grid](https://craftquantities.com/methodology/fastener-schedules-and-grid-counts/): Why a fixing count is never area divided by spacing, why the edges of a panel supply more fasteners than its middle, and why the tighter schedule at a roof corner is a requirement rather than caution.

What this calculation does not cover:

- A count with no screw in it. The tested assembly names the fastener — head style, point and the gauge it can drill — and a fine-thread drywall screw put into a heavier gauge stud will spin without drilling or snap its head under the board. Substituting it is a departure from the listing whether or not the count is right, and on a fire-rated shaft it is the listing, not the arithmetic, that gets inspected.
- Plain studs in a plain run. Jamb studs at openings are commonly boxed or doubled and screwed to each other on a schedule of their own, track splices take fasteners at every joint, and a tall shaft picks up rows of bridging or bracing across the run — each adds screws the stud count above cannot see.

## Sources

As the calculator cites them (sources checked 2026-09-06):

- Total screws = stud count × screws per stud, the same fastening-count method used for standard cold-formed steel stud framing

A code or standard has force only where a jurisdiction has adopted it, usually with local amendments; check what is in force with the authority where you build.

## Questions answered on the page

**Why is this a simple multiplication of stud count by screws per stud?**

Because every stud in the run gets the same schedule, whatever that schedule is — so the total scales directly with the stud count. What the schedule says is the part worth checking rather than assuming. Many tested shaftwall assemblies deliberately leave the stud UNFASTENED at the head so the deflection track can move, in which case only the bottom connection is counted; this site's own shaftwall guide calls screwing the stud through the deflection track legs the commonest field error on these walls. Take the number from the listing for the assembly you are building and enter it above.

**How many screws per stud should I use?**

Use the number specified in your project's fastening schedule or the track manufacturer's installation instructions — this can vary based on stud gauge, track type, and local code requirements.

**Where do I get the stud count for this calculator?**

Use the stud count from your shaftwall layout, such as the result from a shaftwall stud framework calculation for the same wall run.

## Related calculators

- [Shaftwall Stud Framework Calculator](https://craftquantities.com/calculators/materials-quantities/shaftwall-stud-framework-calculator/)
- [CFS Stud Wall Screw Count Calculator](https://craftquantities.com/calculators/materials-quantities/cfs-stud-wall-screw-calculator/)

## Run it from a program

- REST: `GET https://api.craftquantities.com/v1/calculate/shaftwall-screw-count-calculator` with each input as a query parameter, a length, area or volume with its unit; `https://api.craftquantities.com/v1/describe/shaftwall-screw-count-calculator` lists the inputs.
- MCP: the `calculate` tool at https://api.craftquantities.com/mcp with `slug` `shaftwall-screw-count-calculator`.
- Definition and test vectors: https://craftquantities.com/api/v1/calculators/shaftwall-screw-count-calculator.json

---
Source: https://craftquantities.com/calculators/materials-quantities/shaftwall-screw-count-calculator/
Craft Quantities: free to read, cite and link to; the pages are not licensed for republication. Quantities only: no prices, no design and no certification.