# Fire-Rated Shaftwall Liner Panel Count Calculator

> Calculate how many shaftwall liner panels are needed to fill the stud cavities of a shaft wall assembly.

Page: https://craftquantities.com/calculators/materials-quantities/shaftwall-liner-panel-calculator/ (calculator). This is the page's Markdown copy; the HTML page is the canonical version.

Version 1.0.1, sources checked 2026-09-02, 2 published test vectors.

Liner panels needed: 17 panels for Wall Length 33 ft and Liner Panel Width 2 ft, the page's opening figures; on the metric page, 10 m and 0.61 m give 17 panels. Sources are cited below.

## Inputs

A length, area or volume is entered with its unit. The page opens on the values below: a metric reader sees the metric column, a US customary reader the other.

| Input | id | Opens at (metric) | Opens at (US customary) | Accepts |
|---|---|---|---|---|
| Wall Length | `wallLength` | 10 m | 33 ft | mm, cm, m, in, ft, yd; range 0.01–60 m |
| Liner Panel Width | `linerPanelWidth` | 0.61 m | 2 ft | mm, cm, m, in, ft, yd; range 0.01–0.7 m |

- **Wall Length**: The total length of the shaft wall run.
- **Liner Panel Width**: The width of one shaftwall liner panel.

## The answer on the opening values

Worked exactly as the page works it, on the values each system opens on.

### Metric

| Result | Value |
|---|---|
| **Liner panels needed** | 17 panels |

### US customary

| Result | Value |
|---|---|
| **Liner panels needed** | 17 panels |

## How it is worked out

The method, derived in full:

- [Rolls, Sheets and the Lap Between Them](https://craftquantities.com/methodology/rolls-sheets-and-laps/): Why covering an area with rolls is a strip count rather than a division, why the lap is bought twice over, and why turning the strips the other way can change the order.

What this calculation does not cover:

- Stud spacing is not an input, so the panel width is assumed to be the stud module — but a friction-fit liner only works when the two are the same. If the assembly listing calls for C-H studs at 406 mm (16 in) centres while the panel stays 610 mm (24 in) wide, a 10 m run has 25 bays to fill and this returns 17, because it counts panel widths along the wall rather than bays between studs.
- Wall height is not an input, so the result assumes one panel per bay running floor to soffit in a single piece. Shaft liner is supplied in fixed lengths that stop well short of a tall storey — a 16 ft (about 4.9 m) maximum is common, and it varies by manufacturer — and a storey deeper than that needs panels stacked in the bay with an H-stud or a fire-stopped end joint at every splice, which multiplies the count per bay and adds a detail this number knows nothing about.
- The length is treated as one straight, continuous run, so the rounding up happens once for the whole figure instead of once at each corner. Four 2.5 m shaft faces are 5 panels each and 20 in total, while entering their 10 m combined length returns 17. The input also stops at 60 m, so a long run or a whole shaft perimeter has to be split and each face counted on its own.
- Nothing in the result responds to the fire rating being sought — a one-hour and a two-hour shaft of the same length return the same liner count. The rating is carried by the tested assembly as a whole: the stud section, the liner thickness, the number and orientation of finish-side gypsum layers, and the joint treatment. A correct panel count assembled outside that listing is not a rated wall.
- The last panel is counted whole even when only a 100 mm strip is wanted, and the offcut is assumed to be scrap rather than carried to the next bay. No waste percentage, breakage allowance or spare panels are added on top, which matters for a 25 mm liner board that is slid in edgewise and damages easily at the edge, so runs with several returns or openings need an allowance set separately.
- The count covers the liner only. C-H studs, J-runners and floor and head track, the finish-side board layers, fasteners, tape and the head-of-wall deflection detail are all outside it, as is any check that the assembly can carry the shaft pressure it will see in service.

A professional must decide:

- Electrics: circuit design, protection, cable sizing and the work itself are for a qualified or licensed electrician, under the rules where you build.

## Sources

As the calculator cites them (sources checked 2026-09-02):

- Liner panel count = ceil(wall length ÷ liner panel width) — shaftwall liner panels are commonly 1 in thick and 24 in wide, friction-fit between the shaftwall studs

A code or standard has force only where a jurisdiction has adopted it, usually with local amendments; check what is in force with the authority where you build.

## Questions answered on the page

**Why is this panel installed from outside the shaft?**

Because there is nowhere to stand inside one. A lift shaft or a service riser is an open drop for the height of the building, and the entire point of the shaftwall system is that it can be erected from the floor side: the liner panel slides edgewise into the C-H studs already standing, and the operative never enters the shaft or works off a platform inside it. That constraint shapes the product — the panels are typically 25 mm gypsum in a moisture-resistant core, sized to slide rather than to be screwed through, and their edges are what carry the fire rating at the joint. It is a safety-of-construction decision expressed as a board, which is why the quantity is counted by panel and by shaft height rather than by wall area.

**Why are liner panels sized by wall length, not area?**

Shaftwall liner panels stand vertically, friction-fit between adjacent CH studs to span the full height of the wall in one piece — so the quantity needed depends on how many panel widths fit along the wall's length, not the wall's total area.

**How wide and thick is a standard shaftwall liner panel?**

Shaftwall liner panels are commonly 1 in thick and 24 in (about 0.61 m) wide, but always confirm the exact width from your specific manufacturer's product data before finalizing a takeoff.

**Does this account for door or louver openings in the shaft wall?**

No — this calculates the base liner panel count for a continuous wall length only. Openings for doors, louvers, or access panels should be deducted from your layout separately.

## Related calculators

- [Shaftwall Stud Framework Calculator](https://craftquantities.com/calculators/materials-quantities/shaftwall-stud-framework-calculator/)
- [Multi-Layer Fire-Rated (Type X) Gypsum Sheet Calculator](https://craftquantities.com/calculators/materials-quantities/fire-rated-gypsum-layer-calculator/)

## Run it from a program

- REST: `GET https://api.craftquantities.com/v1/calculate/shaftwall-liner-panel-calculator` with each input as a query parameter, a length, area or volume with its unit; `https://api.craftquantities.com/v1/describe/shaftwall-liner-panel-calculator` lists the inputs.
- MCP: the `calculate` tool at https://api.craftquantities.com/mcp with `slug` `shaftwall-liner-panel-calculator`.
- Definition and test vectors: https://craftquantities.com/api/v1/calculators/shaftwall-liner-panel-calculator.json

---
Source: https://craftquantities.com/calculators/materials-quantities/shaftwall-liner-panel-calculator/
Craft Quantities: free to read, cite and link to; the pages are not licensed for republication. Quantities only: no prices, no design and no certification.