# Ridge Beam Tributary Load Calculator

> Calculate the load per linear meter carried by a structural ridge beam supporting cathedral-ceiling rafters.

Page: https://craftquantities.com/calculators/materials-quantities/ridge-beam-tributary-load-calculator/ (calculator). This is the page's Markdown copy; the HTML page is the canonical version.

Version 1.1.1, sources checked 2026-09-06, 2 published test vectors.

Ridge beam load per linear meter: 543 lbf/ft for Total Roof Load, Dead+Live 41.77 psf and Building Width 26 ft, the page's opening figures; on the metric page, 2 kPa and 8 m give 8 kN/m. Sources are cited below.

## Inputs

A length, area or volume is entered with its unit. The page opens on the values below: a metric reader sees the metric column, a US customary reader the other.

| Input | id | Opens at (metric) | Opens at (US customary) | Accepts |
|---|---|---|---|---|
| Total Roof Load, Dead+Live | `roofLoad` | 2 kPa | 41.7709 psf | pa, kpa, mpa, psi, psf, in_wc; range 500–6000 Pa |
| Building Width | `buildingWidth` | 8 m | 26 ft | mm, cm, m, in, ft, yd; range 0.01–20 m |

- **Total Roof Load, Dead+Live**: The combined dead and live load carried by the roof, per unit of horizontal roof area.
- **Building Width**: The full width of the building, measured eave to eave across both roof slopes.

## The answer on the opening values

Worked exactly as the page works it, on the values each system opens on.

### Metric

| Result | Value |
|---|---|
| **Ridge beam load per linear meter** | 8 kN/m |

### US customary

| Result | Value |
|---|---|
| **Ridge beam load per linear meter** | 543 lbf/ft |

- Confidence: medium.

## How it is worked out

Assumes simply-supported rafters bearing directly on a structural ridge beam with no rafter ties — verify actual load path with a structural engineer for irregular framing.

The method, derived in full:

- [Snow, Uplift and the Roof's Load Path](https://craftquantities.com/methodology/roof-loads-and-the-load-path/): Why a warm sheltered roof carries more snow than an exposed cold one, why building next to an existing low roof can overload it without touching it, and why a collar tie and a rafter tie are not the same member.

What this calculation does not cover:

- Produces a load, not a beam. The section comes from applying that load over the clear span between supports and checking it three ways — bending, shear at the bearings, and a deflection limit tight enough that the ridge does not sag visibly over a cathedral ceiling — and doubling the span roughly quadruples the bending demand at the same load per unit length.
- Stops at the underside of the beam. All the load on it lands on the posts at its ends, and those posts have to run continuously down through the floors to a footing sized for that point load. A ridge beam bearing on a wall top plate with ordinary studs and no post beneath it is the common failure, and it shows as a dip in the floor below long before the roof complains.

A professional must decide:

- Structure: sizes, thicknesses, spans, reinforcement and bearing are a structural engineer's or the building official's decision. This is a quantity, not a design.

## Sources

As the calculator cites them (sources checked 2026-09-06):

- For a structural ridge beam supporting simply-supported rafters (no ceiling rafter ties), each rafter transfers half its tributary load to the ridge; summed across both roof sides, ridge load per unit length = roof load × building width ÷ 2

A code or standard has force only where a jurisdiction has adopted it, usually with local amendments; check what is in force with the authority where you build.

## Questions answered on the page

**Why does a structural ridge beam carry load from the full building width?**

Because without ceiling rafter ties to resist outward thrust, each rafter behaves as a simply-supported beam spanning between the wall and the ridge. The ridge beam ends up carrying half the tributary load from each of the two roof slopes, which together sum to half the full building width's roof load.

**Does this apply to a standard ridge board as well?**

No — a conventional ridge board is not a structural beam; it relies on rafter ties (or a ceiling diaphragm) to resist thrust and does not carry this kind of tributary gravity load. This calculator applies specifically to a structural ridge beam in a cathedral-ceiling or open-ridge design.

**What load path assumption does this calculator make?**

It assumes simply-supported rafters bearing directly on the ridge beam with no intermediate supports or rafter ties — irregular framing, dormers, or valleys will change the actual tributary area and should be checked separately by a structural engineer.

## Related calculators

- [Ground-to-Roof Snow Load Calculator](https://craftquantities.com/calculators/materials-quantities/roof-snow-load-calculator/)
- [Timber Beam Bending Stress Calculator](https://craftquantities.com/calculators/materials-quantities/timber-beam-bending-stress-calculator/)

## Run it from a program

- REST: `GET https://api.craftquantities.com/v1/calculate/ridge-beam-tributary-load-calculator` with each input as a query parameter, a length, area or volume with its unit; `https://api.craftquantities.com/v1/describe/ridge-beam-tributary-load-calculator` lists the inputs.
- MCP: the `calculate` tool at https://api.craftquantities.com/mcp with `slug` `ridge-beam-tributary-load-calculator`.
- Definition and test vectors: https://craftquantities.com/api/v1/calculators/ridge-beam-tributary-load-calculator.json

---
Source: https://craftquantities.com/calculators/materials-quantities/ridge-beam-tributary-load-calculator/
Craft Quantities: free to read, cite and link to; the pages are not licensed for republication. Quantities only: no prices, no design and no certification.