# Reverberation Time Calculator (Sabine RT60)

> A room's reverberation time (RT60) by Sabine, from its size and each surface's absorption coefficient, and the absorption or absorber a target time needs.

Page: https://craftquantities.com/calculators/materials-quantities/reverberation-time-calculator/ (calculator). This is the page's Markdown copy; the HTML page is the canonical version.

Version 1.0.0, sources checked 2026-10-05, 5 published test vectors.

Reverberation time: 1.94 s for Room Length 26 ft, Room Width 23 ft and Ceiling Height 9 ft, the page's opening figures, to compare with the limit shown with it; a comparison, not a check. Sources are cited below.

## Inputs

A length, area or volume is entered with its unit. The page opens on the values below: a metric reader sees the metric column, a US customary reader the other.

| Input | id | Opens at (metric) | Opens at (US customary) | Accepts |
|---|---|---|---|---|
| Room Length | `roomLength` | 8 m | 26 ft | mm, cm, m, in, ft, yd; range 0.5–200 m |
| Room Width | `roomWidth` | 7 m | 23 ft | mm, cm, m, in, ft, yd; range 0.5–200 m |
| Ceiling Height | `roomHeight` | 2.7 m | 9 ft | mm, cm, m, in, ft, yd; range 0.5–50 m |
| Floor Absorption Coefficient | `floorAlpha` | 0.04 | 0.04 | range 0–1 |
| Ceiling Absorption Coefficient | `ceilingAlpha` | 0.1 | 0.1 | range 0–1 |
| Wall Absorption Coefficient | `wallAlpha` | 0.06 | 0.06 | range 0–1 |
| Window and Glazing Area | `windowArea` | 8 m² | 86 sq ft | m2, ft2, mm2, in2; range 0–10000 m² |
| Window Absorption Coefficient | `windowAlpha` | 0.05 | 0.05 | range 0–1 |
| Door Area | `doorArea` | 2 m² | 21 sq ft | m2, ft2, mm2, in2; range 0–10000 m² |
| Door Absorption Coefficient | `doorAlpha` | 0.08 | 0.08 | range 0–1 |
| Added Absorber Area | `absorberArea` | 0 m² | 0 sq ft | m2, ft2, mm2, in2; range 0–10000 m² |
| Absorber's Coefficient | `absorberAlpha` | 1 | 1 | range 0.01–1 |
| Absorber Fitted On | `absorberOn` | The ceiling (it replaces that much ceiling) | The ceiling (it replaces that much ceiling) | `ceiling`, `walls` |
| Target Reverberation Time (seconds) | `targetTime` | 0.8 | 0.8 | range 0.1–10 |

- **Room Length**: The room's internal length, wall face to wall face.
- **Room Width**: The room's internal width, measured square to the length.
- **Ceiling Height**: Floor to ceiling, or to the face of a suspended ceiling where there is one.
- **Floor Absorption Coefficient**: The share of sound energy the floor finish absorbs at the band you are working in; 0.04 is lino or parquet on concrete at 500 Hz.
- **Ceiling Absorption Coefficient**: The ceiling's coefficient at the same band; 0.10 is a suspended plasterboard ceiling with a large air space behind it, at 500 Hz.
- **Wall Absorption Coefficient**: The coefficient of the wall finish, not counting windows and doors; 0.06 is painted concrete block at 500 Hz.
- **Window and Glazing Area**: The glazed area in the walls, taken off the wall area and given its own coefficient.
- **Window Absorption Coefficient**: 0.05 at 500 Hz for windows and glass façades in Approved Document E's Table 7.1.
- **Door Area**: The area of the doors in the walls, taken off the wall area and given their own coefficient.
- **Door Absorption Coefficient**: 0.08 at 500 Hz for timber doors in Approved Document E's Table 7.1.
- **Added Absorber Area**: Acoustic panels or tiles fitted over part of the ceiling or walls; zero for none.
- **Absorber's Coefficient**: The maker's practical absorption coefficient at the same band; 1.00 is Rockfon Sonar 20 mm (0.79 in) thick on a 200 mm (7.9 in) suspension at 500 Hz.
- **Absorber Fitted On**: Which surface the panels or tiles cover; the covered area stops counting at that surface's own coefficient.
- **Target Reverberation Time (seconds)**: The time your brief or standard asks for; the page opens on 0.8 s, a new secondary classroom under the UK's BB93.

## The answer on the opening values

Worked exactly as the page works it, on the values each system opens on.

### Metric

| Result | Value |
|---|---|
| **Reverberation time** | 1.92 s |
| Room volume | 151.2 m³ |
| Room surface area | 193 m² |
| Total sound absorption, A | 12.66 m² |
| Average absorption coefficient | 0.07 |
| Absorption to add for the target time | 17.77 m² |
| Absorber area for that, at its coefficient | 19.74 m² |

### US customary

| Result | Value |
|---|---|
| **Reverberation time** | 1.94 s |
| Room volume | 5,382 ft³ |
| Room surface area | 2,078 sq ft |
| Total sound absorption, A | 136.2 sq ft |
| Average absorption coefficient | 0.07 |
| Absorption to add for the target time | 193.94 sq ft |
| Absorber area for that, at its coefficient | 215.49 sq ft |

- Confidence: medium.
- The figure is compared against a limit; that is a check of the number, not an approval.

## How it is worked out

Sabine's formula: the room's volume times a constant, divided by its total absorption, gives the seconds a sound takes to die away by 60 decibels; the constant is 0.161 with the volume in cubic metres and the absorption in square metres, and 0.049 with cubic feet and square feet. It is worked at the one octave band the coefficients entered describe, for a room whose absorption is spread fairly evenly. The time worked out is longer than the target entered, by the absorption shown below; how and where to add it is a design decision for the room's acoustician or designer, and the figure here is for one band only.

The working the page shows, in order: Room volume; Room surface area; Total sound absorption, A; Average absorption coefficient; Absorption to add for the target time; Absorber area for that, at its coefficient; then reverberation time.

The method, derived in full:

- [Sound Transmission, Flanking and the Weakest Path](https://craftquantities.com/methodology/sound-transmission-and-flanking/): Why one per cent of open area destroys an otherwise excellent wall, why doubling the mass buys only six decibels, and why an isolator with too little deflection makes vibration worse rather than better.

What this calculation does not cover:

- Sabine's formula assumes sound spreads evenly through the room and that absorption is modest and spread over the surfaces. In a very absorbent room, with an average coefficient of more than about a fifth, it overstates the time; in a room much longer than it is wide or high, or with all the absorption on one surface, the measured decay can differ a good deal from it.
- One octave band. Every coefficient changes with frequency, so a room can be right at 1000 Hz and boom at 125 Hz; work the page band by band with each surface's coefficient for that band, as Approved Document E's Table 7.1 and makers' data give them.
- Furniture, people and air are not counted. Seats, desks, bookshelves and occupants all absorb, and air absorbs noticeably at high frequencies in a large room; school standards such as BB93 state their times for a room finished and furnished but unoccupied.
- It says nothing about sound insulation. Reverberation is how long sound lingers inside a room; how much gets through its walls and floors is a different property, measured and specified separately, and the page's related sound-insulation calculators cover it.
- No standard is checked. The target is the figure entered, and a reverberation time from this formula is a design estimate; whether a finished room meets a specification is settled by measuring it to the method that specification names.

## Sources

As the calculator cites them (sources checked 2026-10-05):

- Steven Errede, University of Illinois at Urbana-Champaign, Physics 406 Acoustical Physics of Music, lecture notes 'Auditorium & Room Acoustics' (2017): Sabine's equation T = K V / A with K = 0.049 s/ft (= 0.161 s/m), A the room's absorption in square feet (square metres) of open window; worked example after Backus, 240,000 ft³ with 4,300 absorption units giving 2.7 s, and 7,800 units for 1.5 s <https://courses.physics.illinois.edu/phys406/sp2017/Lecture_Notes/P406POM_Lecture_Notes/P406POM_Lect9.pdf>
- HM Government, Approved Document E: Resistance to the passage of sound (2003 edition incorporating 2004, 2010, 2013 and 2015 amendments), Section 7: absorption area A = surface area x absorption coefficient, summed over the surfaces (7.14–7.16); Table 7.1, absorption coefficients of nine common materials at 250, 500, 1000, 2000 and 4000 Hz; Table 7.2, a worked entrance hall of 3.0 x 4.0 x 2.5 m; Method B's 0.20 m² of absorption per m³ for an entrance hall and 0.25 m² per m³ for a corridor (7.17, 7.18) <https://assets.publishing.service.gov.uk/government/uploads/system/uploads/attachment_data/file/468870/ADE_LOCKED.pdf>
- Department for Education, Building Bulletin 93: Acoustic design of schools, performance standards (February 2015), section 1.5 and Table 6: mid-frequency reverberation time Tmf, the average of the 500 Hz, 1 kHz and 2 kHz octave bands, for rooms finished and furnished but unoccupied; a secondary classroom built new at 0.8 s or less, a primary classroom at 0.6 s or less <https://assets.publishing.service.gov.uk/media/5a8170d3e5274a2e8ab54012/BB93_February_2015.pdf>
- Rockfon, Rockfon Sonar product data: practical sound absorption coefficients αp by octave band, measured to ISO 354 and rated to ISO 11654; 20 mm, A24 edge, 200 mm suspension: 0.55, 0.95, 1.00, 0.90, 1.00, 1.00 at 125 Hz to 4 kHz <https://www.rockfon.co.uk/products/rockfon-sonar/>

The site's pages for the documents these name:

- [Approved Documents to the Building Regulations (England)](https://craftquantities.com/standards/uk-gov/uk-approved-documents/)

A code or standard has force only where a jurisdiction has adopted it, usually with local amendments; check what is in force with the authority where you build.

## Questions answered on the page

**What is reverberation time, and what is RT60?**

The time a sound takes to fade by 60 decibels, to a millionth of its intensity, after the source stops; RT60 and T60 are two names for it. A long time makes speech blur into its own echoes, which is why classrooms are designed short and concert halls longer. It depends on two things only in Sabine's simple model: how big the room is, and how much of the sound its surfaces soak up on each bounce.

**What is an absorption coefficient, and what is a sabin?**

The coefficient is the fraction of sound energy a surface absorbs instead of reflecting: 0 for a perfect mirror, 1 for an open window. Multiply it by the surface's area and you have that surface's absorption, in sabins: a square foot of open window is one sabin, and in metric a square metre of it is one metric sabin, 10.76 of the imperial kind. Add every surface's absorption together and you have A, the bottom of Sabine's formula.

**Why are there two constants, 0.161 and 0.049?**

They are the same constant in two unit systems. With the volume in cubic metres and the absorption in square metres the constant is 0.161 seconds per metre; with cubic feet and square feet it is 0.161 times 0.3048, which is 0.049 to two figures. The page works in metric and shows its answer in seconds to everyone, so a hand calculation with the rounded 0.049 comes out about 0.15% shorter than the page.

**Can I use a product's NRC rating as its coefficient?**

Not for one band. The noise reduction coefficient is an average of four bands, and the weighted αw an index across several; both are useful for comparing products and wrong as the single-band figure Sabine's formula needs. Use the maker's practical coefficient for the octave band you are working, for the mounting you will use, and repeat the page for the other bands.

**How much acoustic panel does a room need?**

Enter the room as it is, set the target time, and the page gives the absorption to add and the panel area that supplies it at the panel's coefficient, allowing for the surface the panels cover. In the metric room the page opens on, about 17.8 m² (191 sq ft) of absorption brings 1.9 s down to 0.8 s at 500 Hz, which is about 19.7 m² (213 sq ft) of tiles rated 1.00 laid in place of plasterboard rated 0.10. Check the other bands before settling a quantity: a panel that does well at 500 Hz may do little at 125 Hz.

## Related calculators

- [Acoustic Ceiling Cloud Suspension Wire Count Calculator](https://craftquantities.com/calculators/materials-quantities/acoustic-ceiling-cloud-wire-calculator/)
- [Decibel Addition and Background Correction Calculator](https://craftquantities.com/calculators/sustainability-compliance/decibel-addition-calculator/)
- [Multi-Stud Wall Sound Transmission Class (STC) Estimator](https://craftquantities.com/calculators/materials-quantities/multi-stud-wall-stc-estimator/)
- [HVAC Duct Silencer Cumulative Insertion Loss Calculator](https://craftquantities.com/calculators/materials-quantities/duct-silencer-insertion-loss-calculator/)
- [Acoustic Reflector Panel Placement Calculator](https://craftquantities.com/calculators/materials-quantities/acoustic-reflector-panel-calculator/)

## Run it from a program

- REST: `GET https://api.craftquantities.com/v1/calculate/reverberation-time-calculator` with each input as a query parameter, a length, area or volume with its unit; `https://api.craftquantities.com/v1/describe/reverberation-time-calculator` lists the inputs.
- MCP: the `calculate` tool at https://api.craftquantities.com/mcp with `slug` `reverberation-time-calculator`.
- Definition and test vectors: https://craftquantities.com/api/v1/calculators/reverberation-time-calculator.json

---
Source: https://craftquantities.com/calculators/materials-quantities/reverberation-time-calculator/
Craft Quantities: free to read, cite and link to; the pages are not licensed for republication. Quantities only: no prices, no design and no certification.