# Rankine Passive Earth Pressure Calculator

> Compute the passive earth pressure resultant that soil provides to resist a wall's sliding, using the Rankine model.

Page: https://craftquantities.com/calculators/materials-quantities/rankine-passive-pressure-calculator/ (calculator). This is the page's Markdown copy; the HTML page is the canonical version.

Version 1.0.1, sources checked 2026-09-06, 2 published test vectors.

Passive pressure resultant: 688 lbf/ft for Embedment Depth 2 ft, the page's opening figures; on the metric page, 0.6 m gives 9.72 kN/m. Sources are cited below.

## Inputs

A length, area or volume is entered with its unit. The page opens on the values below: a metric reader sees the metric column, a US customary reader the other.

| Input | id | Opens at (metric) | Opens at (US customary) | Accepts |
|---|---|---|---|---|
| Embedment Depth (Passive Soil Height) | `embedmentDepth` | 0.6 m | 2 ft | mm, cm, m, in, ft, yd; range 0.01–4 m |
| Soil Friction Angle (φ, degrees) | `soilFrictionAngle` | 30 | 30 | range 15–45 |
| Soil Unit Weight γ | `soilUnitWeight` | 18 kN/m³ | 114.586 pcf | knm3, pcf_weight; range 14–22 kN/m³ |

- **Embedment Depth (Passive Soil Height)**: The depth of soil in front of the wall or footing providing passive resistance.
- **Soil Friction Angle (φ, degrees)**: The soil's angle of internal friction.
- **Soil Unit Weight γ**: The soil's unit weight in front of the wall.

## The answer on the opening values

Worked exactly as the page works it, on the values each system opens on.

### Metric

| Result | Value |
|---|---|
| **Passive pressure resultant** | 9.72 kN/m |
| Rankine passive coefficient (Kp) | 3 |

### US customary

| Result | Value |
|---|---|
| **Passive pressure resultant** | 688 lbf/ft |
| Rankine passive coefficient (Kp) | 3 |

- Confidence: medium.

## How it is worked out

Passive resistance is often unreliable in practice — it requires enough wall movement to mobilize, and can be lost entirely if the soil in front of the wall is later excavated or erodes. Many designers deliberately ignore or heavily discount passive resistance for this reason.

The working the page shows, in order: Rankine passive coefficient (Kp); then passive pressure resultant.

The method, derived in full:

- [Lateral Earth Pressure and the Wall That Resists It](https://craftquantities.com/methodology/lateral-earth-pressure/): Why one soil has three pressures that differ ninefold, why the resultant acts a third of the way up rather than halfway, and why water is what actually fails retaining walls.

What this calculation does not cover:

- There is no water in this model. Below the water table the soil in front of the wall contributes only its buoyant weight, so the resistance from the soil skeleton is far less than the full unit weight entered here suggests, and the water pressure acting on the same face is a separate term this does not compute. Perched water, seepage and a table that rises after rain are not checked at all.
- Rankine here is the cohesionless case against a smooth vertical wall face with level ground in front of it. There is no cohesion term, no wall friction or adhesion, no allowance for ground that falls away from the toe (which reduces passive resistance), and no layering — a single friction angle and unit weight cannot describe soft clay, mixed fill, or a granular layer over something weaker.
- This is the full theoretical passive resistance with no factor of safety and no mobilisation reduction applied. Passive pressure needs far more wall movement to develop than active pressure does, so the resistance actually available at a deflection the structure can tolerate is a fraction of this figure. Deciding how much of it to count is a design judgement the calculator does not make.
- The whole embedment depth entered is treated as effective passive soil. Nothing is subtracted for a frost-affected or disturbed upper zone, topsoil or paving buildup, or for soil that a future utility trench, re-grade or landscaping in front of the wall would remove.
- This is one force per metre run of wall, not a stability check and not a design. It does not check sliding, overturning, bearing pressure, base heave or global slope stability, does not size or reinforce the wall or footing, and includes no load factors and no seismic case. Passive resistance is one term in a check that a qualified engineer has to complete against site-specific geotechnical data.

A professional must decide:

- This is one force per metre run of wall, not a stability check and not a design. It does not check sliding, overturning, bearing pressure, base heave or global slope stability, does not size or reinforce the wall or footing, and includes no load factors and no seismic case.

## Sources

As the calculator cites them (sources checked 2026-09-06):

- Rankine passive earth pressure coefficient: Kp = tan²(45° + φ/2); passive pressure resultant: Pp = 0.5 x Kp x γ x H²

A code or standard has force only where a jurisdiction has adopted it, usually with local amendments; check what is in force with the authority where you build.

## Questions answered on the page

**How is passive pressure different from active pressure?**

Active pressure is the soil pushing on the back of a wall as it tries to move away, and passive pressure the resistance soil provides when a wall (or footing) pushes INTO it. Passive pressure is always larger than active pressure for the same soil, but requires the structure to actually move into the soil to fully develop.

**Why is passive resistance often ignored in design?**

Because it requires several percent of the wall height in movement to fully mobilize, and frost, erosion, utility trenching, or future excavation in front of the wall can disturb it. It is inherently less certain than the soil's own weight or active pressure, so conservative designs often only count a fraction of calculated passive resistance, or none at all.

**Is embedment depth the same as the wall's total height?**

No — it's only the depth of soil in front of the footing (below final grade on the passive side), which is typically much less than the retained soil height on the active side.

## Related calculators

- [Retaining Wall Preliminary Stability Check](https://craftquantities.com/calculators/materials-quantities/retaining-wall-stability-calculator/)
- [Rankine Active Earth Pressure with Surcharge Calculator](https://craftquantities.com/calculators/materials-quantities/active-pressure-surcharge-calculator/)

## Run it from a program

- REST: `GET https://api.craftquantities.com/v1/calculate/rankine-passive-pressure-calculator` with each input as a query parameter, a length, area or volume with its unit; `https://api.craftquantities.com/v1/describe/rankine-passive-pressure-calculator` lists the inputs.
- MCP: the `calculate` tool at https://api.craftquantities.com/mcp with `slug` `rankine-passive-pressure-calculator`.
- Definition and test vectors: https://craftquantities.com/api/v1/calculators/rankine-passive-pressure-calculator.json

---
Source: https://craftquantities.com/calculators/materials-quantities/rankine-passive-pressure-calculator/
Craft Quantities: free to read, cite and link to; the pages are not licensed for republication. Quantities only: no prices, no design and no certification.