# Pressure Reducing Valve (PRV) Sizing Calculator

> Calculate the flow coefficient (Cv) needed to select a pressure reducing valve for a given flow rate and pressure drop.

Page: https://craftquantities.com/calculators/materials-quantities/prv-sizing-calculator/ (calculator). This is the page's Markdown copy; the HTML page is the canonical version.

Version 1.1.1, sources checked 2026-09-06, 2 published test vectors.

Required flow coefficient (Cv): 11.2 Cv for Design Flow Rate 50 gal/min and Pressure Drop Across Valve 20 psi, the page's opening figures; on the metric page, 189.27 L/min and 137.9 kPa give 11.2 Cv. Sources are cited below.

## Inputs

A length, area or volume is entered with its unit. The page opens on the values below: a metric reader sees the metric column, a US customary reader the other.

| Input | id | Opens at (metric) | Opens at (US customary) | Accepts |
|---|---|---|---|---|
| Design Flow Rate | `designFlow` | 189.27 L/min | 50 gal/min | lpm, lps, gpm; range 0.1–1893 L/min |
| Pressure Drop Across Valve | `pressureDrop` | 137.895 kPa | 20 psi | pa, kpa, mpa, psi, psf, in_wc; range 34474–689476 Pa |

- **Design Flow Rate**: The design (peak) flow rate the valve must pass.
- **Pressure Drop Across Valve**: The target pressure drop across the valve at design flow.

## The answer on the opening values

Worked exactly as the page works it, on the values each system opens on.

### Metric

| Result | Value |
|---|---|
| **Required flow coefficient (Cv)** | 11.2 Cv |

### US customary

| Result | Value |
|---|---|
| **Required flow coefficient (Cv)** | 11.2 Cv |

- Confidence: medium.

## How it is worked out

This is the standard simplified Cv equation for water service — always confirm the selected valve's actual rated Cv from the manufacturer's catalog at your specific operating conditions before final selection.

The method, derived in full:

- [Head Loss, Falls and Surge: Resistance in Pipes, Ducts and Drains](https://craftquantities.com/methodology/head-loss-falls-and-surge/): Why one pipe size up cuts the friction to a third, why a compressed flex duct can cost four times its rated loss, why a drain can be too steep, and why a fast-closing valve produces a pressure the pump never could.

What this calculation does not cover:

- Cv answers flow, and what destroys pressure reducing valves is cavitation. Whether the valve survives its own drop is a separate check on the RATIO of the drop to the inlet pressure above vapor pressure, judged against that valve's own pressure recovery coefficient - a globe-style PRV taking most of its inlet pressure across one seat will flash and collapse bubbles on the downstream side, chewing out the trim and making a noise like gravel in the pipe. Large reductions are split across two valves in series or given anti-cavitation trim, and the Cv from this page will look entirely correct on the valve that fails.
- Sized at one flow, and buildings run at all of them. A direct-acting PRV droops in outlet pressure as flow rises and creeps back up as flow falls away, so a valve chosen for peak demand sits almost shut at three in the morning and can let downstream pressure drift toward inlet at no flow. The standard answer on a riser is a parallel pair - a small valve carrying night and trickle flows, a large one that opens at peak - which is a decision a single-point Cv never puts in front of you.
- A PRV turns everything downstream into a closed system. Water heated behind a valve that will not pass flow backward expands with nowhere to go, and the pressure climbs quickly enough to lift the relief valve on the heater, which is why a thermal expansion tank on the cold feed is required wherever a PRV, check valve or backflow preventer closes the system. That tank is sized from the heater volume and the pressure settings, and has nothing to do with Cv.

## Sources

As the calculator cites them (sources checked 2026-09-06):

- Simplified valve flow coefficient equation for water: Cv = Q ÷ √(ΔP), where Q is flow rate (gpm) and ΔP is the pressure drop across the valve (psi) — the standard method used in valve manufacturers' catalogs to select a valve size for a target flow and pressure drop

A code or standard has force only where a jurisdiction has adopted it, usually with local amendments; check what is in force with the authority where you build.

## Questions answered on the page

**What is Cv and why does it matter for valve selection?**

Cv (flow coefficient) is a standard rating used in manufacturers' catalogs that describes how much flow a valve passes for a given pressure drop. Calculating the Cv your application needs lets you pick a valve model/size whose rated Cv meets or exceeds that value.

**Why does a larger pressure drop reduce the required Cv?**

Because the equation divides flow rate by the square root of the pressure drop. For the same flow rate, a bigger pressure drop across the valve means the valve doesn't need to be as "open" a flow path to reach that flow, so a smaller Cv (and often a smaller valve) is enough.

**Is this simplified equation accurate enough for final valve selection?**

It's the standard simplified Cv equation for water service and works well for a first-pass estimate, but you should always confirm the selected valve's actual rated Cv from the manufacturer's catalog at your specific operating conditions before finalizing the selection.

## Related calculators

- [Backflow Preventer Discharge Velocity Calculator](https://craftquantities.com/calculators/materials-quantities/backflow-preventer-velocity-calculator/)
- [Backflow Preventer Relief Valve Discharge Calculator](https://craftquantities.com/calculators/materials-quantities/relief-valve-discharge-calculator/)

## Run it from a program

- REST: `GET https://api.craftquantities.com/v1/calculate/prv-sizing-calculator` with each input as a query parameter, a length, area or volume with its unit; `https://api.craftquantities.com/v1/describe/prv-sizing-calculator` lists the inputs.
- MCP: the `calculate` tool at https://api.craftquantities.com/mcp with `slug` `prv-sizing-calculator`.
- Definition and test vectors: https://craftquantities.com/api/v1/calculators/prv-sizing-calculator.json

---
Source: https://craftquantities.com/calculators/materials-quantities/prv-sizing-calculator/
Craft Quantities: free to read, cite and link to; the pages are not licensed for republication. Quantities only: no prices, no design and no certification.