# Post-Tensioned Anchor Seating Loss Calculator

> Estimate the prestress force lost to anchor seating (wedge draw-in) in a short post-tensioned tendon.

Page: https://craftquantities.com/calculators/materials-quantities/post-tensioned-anchor-loss-calculator/ (calculator). This is the page's Markdown copy; the HTML page is the canonical version.

Version 1.0.1, sources checked 2026-09-06, 2 published test vectors.

Stress loss from anchor seating: 12,100 psi for Tendon Length 49 ft, Anchor Set 0.25 in and Strand Cross-Sectional Area 0.15 in², the page's opening figures; on the metric page, 15 m, 6.35 mm and 98.7 mm² give 83.2 MPa. Sources are cited below.

## Inputs

A length, area or volume is entered with its unit. The page opens on the values below: a metric reader sees the metric column, a US customary reader the other.

| Input | id | Opens at (metric) | Opens at (US customary) | Accepts |
|---|---|---|---|---|
| Tendon Length | `tendonLength` | 15 m | 49 ft | mm, cm, m, in, ft, yd; range 0.01–60 m |
| Anchor Set (Wedge Draw-In) | `anchorSetLoss` | 6.35 mm | 0.25 in | mm, cm, m, in, ft, yd; range 0.003–0.015 m |
| Strand Cross-Sectional Area | `strandAreaMm2` | 98.7 mm² | 0.152985 in² | m2, ft2, mm2, in2; range 0.00005–0.0002 m² |

- **Tendon Length**: The length of the post-tensioned tendon.
- **Anchor Set (Wedge Draw-In)**: The seating loss distance for your specific anchorage system.
- **Strand Cross-Sectional Area**: The nominal cross-sectional area of one strand.

## The answer on the opening values

Worked exactly as the page works it, on the values each system opens on.

### Metric

| Result | Value |
|---|---|
| **Stress loss from anchor seating** | 83.2 MPa |
| Stress loss (imperial) | 12,065 psi |
| Force loss per strand | 8.21 kN |
| Force loss per strand (imperial) | 1,845.77 lbs |

### US customary

| Result | Value |
|---|---|
| **Stress loss from anchor seating** | 12,100 psi |
| Stress loss (imperial) | 12,117.35 psi |
| Force loss per strand | 1.85 kips |
| Force loss per strand (imperial) | 1,853.78 lbs |

- Confidence: medium.

## How it is worked out

This simplified short-tendon method assumes the seating loss propagates the full tendon length — a licensed PT designer must verify this assumption and account for friction losses along the tendon for a final design.

The working the page shows, in order: Stress loss (imperial); Force loss per strand; Force loss per strand (imperial); then stress loss from anchor seating.

The method, derived in full:

- [Bond, Development and Lap Length](https://craftquantities.com/methodology/bond-development-and-lap/): Why anchorage length scales with bar diameter rather than area, why bond actually fails by splitting the cover rather than by sliding, and why a lap is longer than a development length.

What this calculation does not cover:

- Friction is not in this model. It spreads the wedge draw-in uniformly over the entire tendon, ignoring the strand-to-duct or strand-to-sheathing friction that in a real tendon confines seating loss to a set-influence length near the stressing end. Where friction matters, the actual loss at the anchorage is higher than this figure and falls away to nothing further along the tendon.
- This is the seating loss alone, not the effective prestress. Elastic shortening of the concrete, creep, shrinkage, steel relaxation, and wobble and curvature friction along the tendon profile are all excluded, as is any set at the dead end.
- The strand modulus is fixed at the standard 7-wire value and cannot be changed. The result does not apply to threadbar or other bar systems, or to strand of a different grade or modulus. The force figure is per single strand and is not multiplied up for the strands in a tendon or the tendons in a slab.
- Nothing checks that the computed loss is physically achievable. The calculator never compares it against your jacking stress or the strand's breaking strength, so a very short tendon length returns a loss larger than the prestress the tendon could ever have held, with no warning on the page.
- This is not a post-tensioning design and does not replace one. Anchor set must come from the anchorage supplier's data for the system actually being installed, and the stressing sequence, tendon profile, jacking force and final effective prestress are a licensed PT designer's work.

A professional must decide:

- This is not a post-tensioning design and does not replace one. Anchor set must come from the anchorage supplier's data for the system actually being installed, and the stressing sequence, tendon profile, jacking force and final effective prestress are a licensed PT designer's work.
- Structure: sizes, thicknesses, spans, reinforcement and bearing are a structural engineer's or the building official's decision. This is a quantity, not a design.

## Sources

As the calculator cites them (sources checked 2026-09-06):

- Post-Tensioning Institute (PTI) simplified short-tendon seating loss method: stress loss = (anchor set / tendon length) x strand modulus of elasticity — valid when the seating-loss effect propagates the full tendon length, the common case for short-to-medium span slab tendons
- Standard 7-wire strand elastic modulus: 28,500,000 psi; typical anchor set (wedge draw-in) is commonly 1/4 to 3/8 in depending on the anchorage system

A code or standard has force only where a jurisdiction has adopted it, usually with local amendments; check what is in force with the authority where you build.

## Questions answered on the page

**What is 'anchor set' or 'wedge draw-in'?**

When the stressing jack releases a tendon, the wedges grip the strand and settle slightly into the anchor casting before fully locking — that small settlement distance is the anchor set, and it releases a small amount of the applied prestress force.

**Is this loss significant?**

For short tendons it can be a meaningful fraction of the total prestress force, since the same fixed seating distance is spread over a shorter length — which is exactly why this calculator's ratio uses tendon length in the denominator.

**Does this replace a full PT design?**

No — a complete post-tensioning design also accounts for friction losses along the tendon profile, elastic shortening, creep, shrinkage, and relaxation losses, and must be performed by a licensed PT designer.

## Related calculators

- [Concrete Calculator](https://craftquantities.com/calculators/materials-quantities/concrete-calculator/)
- [Reinforced Concrete Beam Moment Capacity Calculator (ACI 318)](https://craftquantities.com/calculators/materials-quantities/rc-beam-moment-capacity-calculator/)

## Run it from a program

- REST: `GET https://api.craftquantities.com/v1/calculate/post-tensioned-anchor-loss-calculator` with each input as a query parameter, a length, area or volume with its unit; `https://api.craftquantities.com/v1/describe/post-tensioned-anchor-loss-calculator` lists the inputs.
- MCP: the `calculate` tool at https://api.craftquantities.com/mcp with `slug` `post-tensioned-anchor-loss-calculator`.
- Definition and test vectors: https://craftquantities.com/api/v1/calculators/post-tensioned-anchor-loss-calculator.json

---
Source: https://craftquantities.com/calculators/materials-quantities/post-tensioned-anchor-loss-calculator/
Craft Quantities: free to read, cite and link to; the pages are not licensed for republication. Quantities only: no prices, no design and no certification.