# Steel Plate Block Shear and Net Section Calculator

> Run every failure line through a bolted connection plate (net section rupture, block shear, Whitmore section, gross yielding) and see which governs.

Page: https://craftquantities.com/calculators/materials-quantities/plate-block-shear-net-section-calculator/ (calculator). This is the page's Markdown copy; the HTML page is the canonical version.

Version 1.0.1, sources checked 2026-09-06, 4 published test vectors.

Governing design strength: 81.3 kips for Plate Thickness 0.39 in, Steel Yield Strength Fy 50038.02 psi and Steel Tensile Strength Fu 65266.98 psi, the page's opening figures; on the metric page, 10 mm, 345 MPa and 450 MPa give 375 kN. Sources are cited below.

## Inputs

A length, area or volume is entered with its unit. The page opens on the values below: a metric reader sees the metric column, a US customary reader the other.

| Input | id | Opens at (metric) | Opens at (US customary) | Accepts |
|---|---|---|---|---|
| Plate Thickness | `plateThickness` | 10 mm | 0.39 in | mm, cm, m, in, ft, yd; range 0.004–0.05 m |
| Steel Yield Strength Fy | `yieldStrength` | 345 MPa | 50038 psi | pa, kpa, mpa, psi, psf, in_wc; range 200000000–700000000 Pa |
| Steel Tensile Strength Fu | `tensileStrength` | 450 MPa | 65267 psi | pa, kpa, mpa, psi, psf, in_wc; range 300000000–900000000 Pa |
| Hole Width Deducted for Net Area | `holeDiameter` | 22 mm | 0.87 in | mm, cm, m, in, ft, yd; range 0.008–0.05 m |
| Bolt Lines Across the Plate (count) | `boltLines` | 2 | 2 | range 2–8 |
| Bolts in Each Line, Along the Force (count) | `boltsPerLine` | 3 | 3 | range 2–12 |
| Gauge — Spacing Between Bolt Lines | `gauge` | 75 mm | 3 in | mm, cm, m, in, ft, yd; range 0.03–0.3 m |
| Pitch — Spacing Along Each Bolt Line | `pitch` | 75 mm | 3 in | mm, cm, m, in, ft, yd; range 0.03–0.3 m |
| Edge Distance, Outer Bolt Line to Plate Edge | `edgeDistance` | 40 mm | 1.5 in | mm, cm, m, in, ft, yd; range 0.012–0.15 m |
| End Distance, Last Bolt to Plate End | `endDistance` | 40 mm | 1.5 in | mm, cm, m, in, ft, yd; range 0.012–0.3 m |
| Tension Stress Distribution on the Block (Ubs) | `blockShearUbs` | Uniform — a gusset or splice plate in axial tension (Ubs = 1.0) | Uniform — a gusset or splice plate in axial tension (Ubs = 1.0) | `1`, `0.5` |

- **Plate Thickness**: The thickness of the connecting plate or gusset on the failure line.
- **Steel Yield Strength Fy**: The specified minimum yield strength of the plate steel.
- **Steel Tensile Strength Fu**: The specified minimum tensile strength of the plate steel.
- **Hole Width Deducted for Net Area**: The hole width to take out of the section, which is wider than the hole itself.
- **Bolt Lines Across the Plate (count)**: How many lines of bolts sit side by side across the plate, perpendicular to the force.
- **Bolts in Each Line, Along the Force (count)**: How many bolts sit one behind another in a single line, along the direction of the force.
- **Gauge — Spacing Between Bolt Lines**: The spacing between adjacent bolt lines, measured across the plate.
- **Pitch — Spacing Along Each Bolt Line**: The spacing between adjacent bolts within one line, along the force.
- **Edge Distance, Outer Bolt Line to Plate Edge**: From the centre of an outer bolt line to the nearer long edge of the plate.
- **End Distance, Last Bolt to Plate End**: From the centre of the end bolt to the free end of the plate, along the force.
- **Tension Stress Distribution on the Block (Ubs)**: Whether tension is spread evenly across the block's tension plane, or concentrated at one end.

## The answer on the opening values

Worked exactly as the page works it, on the values each system opens on.

### Metric

| Result | Value |
|---|---|
| **Governing design strength** | 375 kN |
| Net section tension rupture | 374.63 kN |
| Block shear rupture | 725.63 kN |
| Yielding on the Whitmore section | 481.28 kN |
| Gross section tension yielding | 481.28 kN |
| Nominal strength at the governing limit state | 499.5 kN |
| Allowable strength at the governing limit state | 249.75 kN |
| Whitmore effective width from the thirty-degree spread | 248.21 mm |
| Gross plate width across the bolt group | 155 mm |
| Area remaining on the rupture line | 1,110 mm² |
| Area remaining on the two shear planes | 2,700 mm² |

### US customary

| Result | Value |
|---|---|
| **Governing design strength** | 81.3 kips |
| Net section tension rupture | 81.33 kips |
| Block shear rupture | 162.65 kips |
| Yielding on the Whitmore section | 105.38 kips |
| Gross section tension yielding | 105.38 kips |
| Nominal strength at the governing limit state | 108.43 kips |
| Allowable strength at the governing limit state | 54.22 kips |
| Whitmore effective width from the thirty-degree spread | 9.93 in |
| Gross plate width across the bolt group | 6 in |
| Area remaining on the rupture line | 1.66 in² |
| Area remaining on the two shear planes | 4.15 in² |

## How it is worked out

The governing limit state is net section tension rupture. The thirty-degree spread reaches past both plate edges, so the Whitmore section has been truncated at the plate's own width — there is no material out there to yield.

The working the page shows, in order: Net section tension rupture; Block shear rupture; Yielding on the Whitmore section; Gross section tension yielding; Nominal strength at the governing limit state; Allowable strength at the governing limit state; Whitmore effective width from the thirty-degree spread; Gross plate width across the bolt group; Area remaining on the rupture line; Area remaining on the two shear planes; then governing design strength.

The method, derived in full:

- [Slope, Pitch and True Surface Area](https://craftquantities.com/methodology/slope-pitch-and-true-area/): Converting a plan footprint into the sloped area a roof actually has — the factor that decides whether a shingle order is right or a third short.

What this calculation does not cover:

- Checks the PLATE only. Bolt shear, bearing and tearout at each hole are Section J3 checks that frequently govern before any of the four run here, and a plate that passes on this page can still fail at the first bolt.
- Does not check the gusset in compression. Buckling on the Whitmore section needs an unbraced length and an effective length factor taken from the detail geometry, and both are outside what a bolt pattern alone can tell you.
- Assumes holes in line, not staggered. A staggered pattern earns back net width through the s²/4g term in AISC 360 Section B4.3, which is not applied here.
- Assumes a flat plate carrying axial force. An angle leg, a tee stem or a coped beam web has different geometry, and the coped web also belongs at Ubs = 0.5.

A professional must decide:

- Structure: sizes, thicknesses, spans, reinforcement and bearing are a structural engineer's or the building official's decision. This is a quantity, not a design.

## Sources

As the calculator cites them (sources checked 2026-09-06):

- AISC 360, Specification for Structural Steel Buildings, Section J4.1 — tensile yielding on the gross area (Rn = Fy·Ag) and tensile rupture on the effective net area, with the effective net area of a connecting element capped at 0.85 times its gross area
- AISC 360, Specification for Structural Steel Buildings, Section J4.2 — shear yielding on the gross area at 0.60·Fy·Agv and shear rupture on the net area at 0.60·Fu·Anv
- AISC 360, Specification for Structural Steel Buildings, Section J4.3 — block shear rupture, Rn = 0.60·Fu·Anv + Ubs·Fu·Ant, not taken greater than 0.60·Fy·Agv + Ubs·Fu·Ant, with Ubs 1.0 for uniform tension stress and 0.5 where it is non-uniform
- R. E. Whitmore, Experimental Investigation of Stresses in Gusset Plates, University of Tennessee Engineering Experiment Station Bulletin No. 16 (1952) — the effective width taken as the thirty-degree spread from the outer fasteners of the first row to the last row, the convention the AISC Steel Construction Manual uses for gusset plate checks
- AISC 360 Section B4.3 — for net area, the width of a bolt hole is taken larger than the hole itself; this page asks for that deduction width directly rather than adding an allowance behind your back

The site's pages for the documents these name:

- [AISC 360](https://craftquantities.com/standards/aisc/aisc-360/)

A code or standard has force only where a jurisdiction has adopted it, usually with local amendments; check what is in force with the authority where you build.

## Questions answered on the page

**Why does the answer use design strengths rather than nominal capacities?**

Because the four limit states do not carry the same resistance factor. Yielding is factored at 0.90 and every rupture at 0.75, so a mode with the smallest nominal capacity is not necessarily the mode that governs the design. Comparing nominal figures and then applying a factor to the winner gets the wrong answer whenever those two orders disagree, which is exactly when the check matters.

**The Whitmore width comes out wider than the plate. Is that a mistake?**

No, and it is worth knowing. The thirty-degree spread is a geometric construction and it routinely opens out past the edges of a narrow plate. There is no steel out there to yield, so the check itself runs on the plate's real width and the note says the section was truncated. The geometric figure is still shown, because when it exceeds the plate width it is telling you the plate is narrower than the load is trying to spread into.

**Can I use this for a coped beam web?**

For the block shear part, with Ubs set to 0.5 — a coped web loads its tension plane eccentrically and AISC 360 halves the tension term for it. The rest does not transfer. A coped web also buckles locally and can crack from the re-entrant corner, and neither of those is a check a bolt pattern can produce; they need the cope geometry and the corner radius.

**Why is there no bolt shear or bearing check here?**

Because those are checks on the bolt and on the material in front of it, not on the plate body, and they live in a different section of the specification. The guide this page came from walks the force through the fasteners first and only then through the plate. A connection that passes every check on this page can still fail by crushing in front of the first bolt, so run the bearing and tearout checks separately before trusting the number here.

## Related calculators

- [Fillet Weld Shear Capacity Calculator](https://craftquantities.com/calculators/materials-quantities/structural-steel-weld-shear-calculator/)
- [Steel Moment Connection Bolt Count Calculator](https://craftquantities.com/calculators/materials-quantities/steel-moment-connection-bolt-calculator/)
- [Steel Stair Stringer Bolt Hole Spacing Calculator](https://craftquantities.com/calculators/materials-quantities/steel-stringer-bolt-hole-spacing-calculator/)
- [Castellated Beam Web Opening Net-Section Shear Calculator](https://craftquantities.com/calculators/materials-quantities/castellated-beam-net-shear-calculator/)

## Run it from a program

- REST: `GET https://api.craftquantities.com/v1/calculate/plate-block-shear-net-section-calculator` with each input as a query parameter, a length, area or volume with its unit; `https://api.craftquantities.com/v1/describe/plate-block-shear-net-section-calculator` lists the inputs.
- MCP: the `calculate` tool at https://api.craftquantities.com/mcp with `slug` `plate-block-shear-net-section-calculator`.
- Definition and test vectors: https://craftquantities.com/api/v1/calculators/plate-block-shear-net-section-calculator.json

---
Source: https://craftquantities.com/calculators/materials-quantities/plate-block-shear-net-section-calculator/
Craft Quantities: free to read, cite and link to; the pages are not licensed for republication. Quantities only: no prices, no design and no certification.