# Mullion Stack Joint Setting Gap Calculator

> Work out the gap to set at a curtain wall stack joint against the thermometer reading on the day of installation, not against the season it happens to be.

Page: https://craftquantities.com/calculators/materials-quantities/mullion-stack-joint-gap-calculator/ (calculator). This is the page's Markdown copy; the HTML page is the canonical version.

Version 1.0.0, sources checked 2026-08-30, 3 published test vectors.

Setting gap at today's temperature: 0.246 in for Floor-to-Floor Mullion Length 12 ft, Coldest Design Metal Temperature -4 °F and Hottest Design Metal Temperature 158 °F, the page's opening figures; on the metric page, 3.6 m, -20 °C and 70 °C give 6.17 mm. Sources are cited below.

## Inputs

A length, area or volume is entered with its unit. The page opens on the values below: a metric reader sees the metric column, a US customary reader the other.

| Input | id | Opens at (metric) | Opens at (US customary) | Accepts |
|---|---|---|---|---|
| Floor-to-Floor Mullion Length | `mullionLength` | 3.6 m | 12 ft | mm, cm, m, in, ft, yd; range 1–8 m |
| Mullion Alloy | `alloy` | Aluminium extrusion (6000 series) | Aluminium extrusion (6000 series) | `aluminium`, `steel`, `stainless` |
| Coldest Design Metal Temperature | `designMinTemp` | -20 °C | -4 °F | c, f, k; range -50–10 °C |
| Hottest Design Metal Temperature | `designMaxTemp` | 70 °C | 158 °F | c, f, k; range 20–100 °C |
| Metal Temperature Measured at Installation | `ambientTemp` | 15 °C | 59 °F | c, f, k; range -30–50 °C |
| Residual Gap Required at the Hottest Temperature | `minimumClosedGap` | 1.5 mm | 0.0590551 in | mm, cm, m, in, ft, yd; range 0–0.01 m |

- **Floor-to-Floor Mullion Length**: The length of one mullion between stack joints — usually the floor-to-floor dimension.
- **Mullion Alloy**: The material of the mullion itself, which sets how far it moves per degree.
- **Coldest Design Metal Temperature**: The lowest temperature the mullion metal itself is expected to reach in service.
- **Hottest Design Metal Temperature**: The highest temperature the mullion metal itself is expected to reach in service.
- **Metal Temperature Measured at Installation**: What the mullion is reading right now, on the face being installed.
- **Residual Gap Required at the Hottest Temperature**: How much clearance must survive when the mullion is at its hottest and the joint is at its tightest.

## The answer on the opening values

Worked exactly as the page works it, on the values each system opens on.

### Metric

| Result | Value |
|---|---|
| **Setting gap at today's temperature** | 6.17 mm |
| Total movement across the design range | 7.65 mm |
| Gap at the coldest design temperature | 9.15 mm |
| Gap at the hottest design temperature | 1.5 mm |
| Expansion still to come from today's reading | 4.67 mm |
| Contraction still to come from today's reading | 2.97 mm |

### US customary

| Result | Value |
|---|---|
| **Setting gap at today's temperature** | 0.246 in |
| Total movement across the design range | 0.31 in |
| Gap at the coldest design temperature | 0.36 in |
| Gap at the hottest design temperature | 0.06 in |
| Expansion still to come from today's reading | 0.19 in |
| Contraction still to come from today's reading | 0.12 in |

## How it is worked out

The working the page shows, in order: Total movement across the design range; Gap at the coldest design temperature; Gap at the hottest design temperature; Expansion still to come from today's reading; Contraction still to come from today's reading; then setting gap at today's temperature.

The method, derived in full:

- [Thermal and Moisture Movement, and the Joint That Absorbs It](https://craftquantities.com/methodology/movement-and-joints/): Why a restrained element's stress is the same whatever its length, why a clay brick outer leaf and a block inner leaf move in opposite directions, and why a joint's width is set by the sealant rather than by the movement.

What this calculation does not cover:

- Covers axial thermal movement of the mullion only. Frame shortening, creep in a concrete structure and differential slab movement all land on the same joint and none of them is temperature-driven.
- Assumes the splice is free to slide. A stack joint pinned by a sealed gasket, a paint bridge or a fastener through the sleeve does not move, and the load goes somewhere else.

A professional must decide:

- Structure: sizes, thicknesses, spans, reinforcement and bearing are a structural engineer's or the building official's decision. This is a quantity, not a design.

## Sources

As the calculator cites them (sources checked 2026-08-30):

- Linear thermal expansion, ΔL = α × L × ΔT — the gap set today is the residual gap at the hottest design temperature plus the expansion still to come between today's reading and that temperature
- Coefficients of linear thermal expansion as published for each alloy family: aluminium extrusion 23.6 × 10⁻⁶ per °C (Aluminum Design Manual, The Aluminum Association), structural carbon steel 11.7 × 10⁻⁶ per °C (AISC Steel Construction Manual), austenitic stainless steel 17.3 × 10⁻⁶ per °C

A code or standard has force only where a jurisdiction has adopted it, usually with local amendments; check what is in force with the authority where you build.

## Questions answered on the page

**Why does the gap depend on today's temperature at all?**

Because the joint has a fixed total travel and today's reading decides where in that travel you are starting. Set a joint on a cold morning to the figure meant for a warm afternoon and you have spent gap you will need in August; set it the other way and the joint is still open in January when it should have taken up.

**Air temperature or metal temperature?**

Metal. The extrusion responds to what it is, not to what the forecast says. A south-facing mullion in spring sunshine can sit 15 to 20 degrees above shade air temperature, and using the air figure would have you set a gap on the assumption the mullion still has that expansion left to do when it has already done it.

**What if the design temperature range in the specification looks too narrow?**

Say so before you set the first joint. The range drives the total travel and therefore the size of the sleeve and the joint cover, and a range that ignores a dark finish in full sun is a detail that will bind. It is a design question and it belongs with the designer, not with the installer holding a feeler gauge.

**Does the gap it gives me include frame shortening and slab movement?**

No. Every movement figure on the page is the extrusion's own expansion — coefficient times length times temperature change — and the only other number in the sum is the residual gap you type in, so nothing here knows anything about the structure the wall hangs off. A concrete frame goes on shortening under shrinkage and creep for months and years after the pour, and that lost floor-to-floor height closes the stack joint with the thermometer sitting still; a long slab edge taking up its live load does the same over an afternoon. Get the predicted figure at your level from the structural engineer and put it into the residual gap field, which is the only way it reaches these numbers: whatever you add there raises the setting gap and both limits by exactly that amount, and the field takes up to 10 mm (about 3/8 in). Then confirm the sleeve is still engaged at the wider open limit.

**What if the joint cannot actually slide once the wall is finished?**

Then the number here describes a movement that is not happening. The arithmetic assumes the splice slides freely, and on site the things that stop it are ordinary: a screw driven through the sleeve to hold the stack during erection and never removed, sealant or a gasket bridging the gap and curing hard across it, touch-up paint over the joint line, swarf or mortar dropped down the pocket. The metal still grows the same millimetres — they load the anchors instead, or travel to the next joint that is free. Prove the splice slides by hand before you set it, and if two floors are pinned together, enter the whole pinned run rather than one storey — up to the 8 m (about 26 ft) the length field takes — to see the movement that now has to go somewhere else.

**Does the coldest design temperature change the gap I set today?**

Not on its own. The setting gap is your residual plus the expansion still owed between today's reading and the hottest design temperature, and the cold figure appears nowhere in that sum. What it fixes is the open limit — how wide the joint sits on the worst winter night — and the contraction line in the breakdown, neither of which is the number your feeler gauge is setting this morning. It only reaches the setting gap when your measured reading is colder than the coldest figure you entered: the answer is then held at the open limit and dropped to medium confidence, which is the page saying your range and your thermometer disagree.

## Related calculators

- [Structural Glazing Mullion Wind Load Deflection Calculator](https://craftquantities.com/calculators/materials-quantities/mullion-deflection-calculator/)
- [Curtain Wall Panel Count Calculator](https://craftquantities.com/calculators/materials-quantities/curtain-wall-panel-count-calculator/)
- [Standing Seam Roof Thermal Movement Calculator](https://craftquantities.com/calculators/materials-quantities/standing-seam-thermal-movement-calculator/)
- [Curtain Wall Perimeter Joint Width Calculator](https://craftquantities.com/calculators/materials-quantities/perimeter-joint-width-calculator/)

## Run it from a program

- REST: `GET https://api.craftquantities.com/v1/calculate/mullion-stack-joint-gap-calculator` with each input as a query parameter, a length, area or volume with its unit; `https://api.craftquantities.com/v1/describe/mullion-stack-joint-gap-calculator` lists the inputs.
- MCP: the `calculate` tool at https://api.craftquantities.com/mcp with `slug` `mullion-stack-joint-gap-calculator`.
- Definition and test vectors: https://craftquantities.com/api/v1/calculators/mullion-stack-joint-gap-calculator.json

---
Source: https://craftquantities.com/calculators/materials-quantities/mullion-stack-joint-gap-calculator/
Craft Quantities: free to read, cite and link to; the pages are not licensed for republication. Quantities only: no prices, no design and no certification.