# Masonry Lintel Bearing Length Checker

> Check whether a lintel's end bearing length meets standard code minimums.

Page: https://craftquantities.com/calculators/materials-quantities/lintel-bearing-length-calculator/ (calculator). This is the page's Markdown copy; the HTML page is the canonical version.

Version 1.0.1, sources checked 2026-09-06, 2 published test vectors.

Provided bearing length: 6 in for Provided Bearing Length 6 in, the page's opening figures, to compare with the limit shown with it; a comparison, not a check. Sources are cited below.

## Inputs

A length, area or volume is entered with its unit. The page opens on the values below: a metric reader sees the metric column, a US customary reader the other.

| Input | id | Opens at (metric) | Opens at (US customary) | Accepts |
|---|---|---|---|---|
| Provided Bearing Length | `providedBearingLength` | 152.4 mm | 6 in | mm, cm, m, in, ft, yd; range 0.01–0.6096 m |
| Lintel Type | `lintelType` | General masonry opening (102 mm / 4 in code minimum) | General masonry opening (4 in code minimum) | `general`, `steel-reinforced`, `concrete-pca` |

- **Provided Bearing Length**: The actual bearing length provided on each end of the lintel.
- **Lintel Type**: The type of lintel, which sets the applicable minimum bearing length.

## The answer on the opening values

Worked exactly as the page works it, on the values each system opens on.

### Metric

| Result | Value |
|---|---|
| **Provided bearing length** | 152 mm |
| Required minimum | 101.6 mm |

### US customary

| Result | Value |
|---|---|
| **Provided bearing length** | 6 in |
| Required minimum | 4 in |

- Confidence: medium.
- The figure is compared against a limit; that is a check of the number, not an approval.

## How it is worked out

The minimum bearing this lintel type calls for is below the bearing you have provided shown with it — you entered it from the drawing. Being under one limit is not a design. Nothing else is checked here — not the other limit states, not the connections, not the member the load arrives from.

The working the page shows, in order: Required minimum; then provided bearing length.

The method, derived in full:

- [Bearing Capacity, and How a Load Spreads Into What Carries It](https://craftquantities.com/methodology/bearing-and-load-spread/): Why the allowable pressure under a footing is usually set by settlement rather than by strength, why a wider footing settles more at the same pressure, and why timber bearing is limited by the weakest direction of the grain.

What this calculation does not cover:

- The three minimums are imperial figures, and the checker converts whatever you enter into inches before comparing, so the result is always reported in inches even in metric mode. A 100 mm bearing, the usual minimum in British and European lintel practice, converts to 3.94 in and is reported as a failure against the 4 in general minimum, a shortfall of 1.6 mm. Treat a marginal fail of that size as a units artefact and check the minimum your own jurisdiction actually specifies, which may be expressed in millimetres and may scale with span.
- This is a comparison of one length against a fixed minimum. It never asks for the load above the opening, the span, or the width of the lintel where it sits on the wall, so it cannot say whether the masonry under the bearing is being crushed. Bearing stress is the end reaction divided by the bearing area, length multiplied by width, and on a long span or a heavily loaded opening that check can demand more bearing than the code minimum, so a pass here is a geometric pass and not a stress pass.
- The figure you measure is how far the lintel overlaps the wall, not how much of that overlap is solidly supported. Bearing over ungrouted hollow block cells, an unfilled perp joint, a chase, a cavity tray or a compressible damp-proof course delivers less effective bearing than the tape shows, and hollow units at the bearing normally have to be filled solid or swapped for a solid-top or bond beam unit before the measured length counts.
- Nothing here examines the masonry beyond the bearing. Load spreads downwards and outwards from the bearing into the wall below, so a narrow pier between two openings, a bearing close to a corner, a movement joint or an unrestrained return can be the real weak point even when the bearing length itself is generous. The required end distance or minimum pier width is a separate check set by your masonry code.
- A passing bearing says nothing about the lintel itself. Whether the section can carry the load over the span, and whether it deflects enough to crack the masonry above or bind the door or window below, are separate questions handled by the lintel load capacity calculator. Deflection over brittle finishes is normally limited to a fraction of the span, commonly somewhere between span over 360 and span over 600 depending on the finish and the jurisdiction, and that limit often governs before strength does.

A professional must decide:

- Structure: sizes, thicknesses, spans, reinforcement and bearing are a structural engineer's or the building official's decision. This is a quantity, not a design.

## Sources

As the calculator cites them (sources checked 2026-09-06):

- Standard building code minimum lintel bearing length is 4 in on each end; steel or reinforced masonry lintels require at least 5 in bearing; the Portland Cement Association recommends a minimum of 6 in for concrete lintels

A code or standard has force only where a jurisdiction has adopted it, usually with local amendments; check what is in force with the authority where you build.

## Questions answered on the page

**Why does bearing length matter?**

Adequate bearing length ensures the load from the lintel (and the masonry above it) transfers safely into solid masonry beyond the opening, without exceeding the masonry's allowable bearing stress or risking a local crushing failure.

**Does bearing stress ever require more than the code minimum?**

Yes — for heavily loaded lintels (long spans, high loads above), the bearing stress calculation may require more bearing length than the minimum to keep stress within allowable limits, even if the minimum is code-compliant on paper.

**Does bearing length differ for wood or steel beams bearing on masonry?**

Similar minimums generally apply, but always check your specific local code and the beam manufacturer's requirements — this calculator uses common masonry-specific lintel bearing minimums.

## Related calculators

- [Masonry Lintel Uniform Load Capacity Calculator](https://craftquantities.com/calculators/materials-quantities/lintel-load-capacity-calculator/)
- [Door & Window Casing Calculator](https://craftquantities.com/calculators/renovation-construction/door-window-casing-calculator/)

## Run it from a program

- REST: `GET https://api.craftquantities.com/v1/calculate/lintel-bearing-length-calculator` with each input as a query parameter, a length, area or volume with its unit; `https://api.craftquantities.com/v1/describe/lintel-bearing-length-calculator` lists the inputs.
- MCP: the `calculate` tool at https://api.craftquantities.com/mcp with `slug` `lintel-bearing-length-calculator`.
- Definition and test vectors: https://craftquantities.com/api/v1/calculators/lintel-bearing-length-calculator.json

---
Source: https://craftquantities.com/calculators/materials-quantities/lintel-bearing-length-calculator/