# Housed Stringer Calculator (Closed String Staircase: Trenches, Wedges and String Length)

> A closed, housed string from your rise, going and board: every tread and riser trench, wedge room, throat, string length and a full-size router gauge.

Page: https://craftquantities.com/calculators/materials-quantities/housed-stringer-calculator/ (calculator). This is the page's Markdown copy; the HTML page is the canonical version.

Version 1.0.0, sources checked 2026-11-13, 5 published test vectors.

String board length: 15.1 ft for Total Rise 8.5 ft, Riser You Are Aiming For 7.5 in and Going 10.25 in, the page's opening figures; on the metric page, 2.6 m, 190 mm and 260 mm give 4.6 m. Source: UK.

## Inputs

A length, area or volume is entered with its unit. The page opens on the values below: a metric reader sees the metric column, a US customary reader the other.

| Input | id | Opens at (metric) | Opens at (US customary) | Accepts |
|---|---|---|---|---|
| Total Rise (floor to floor) | `totalRise` | 2.6 m | 8.5 ft | mm, cm, m, in, ft, yd; range 0.3–8 m |
| Riser You Are Aiming For | `targetRiser` | 190 mm | 7.5 in | mm, cm, m, in, ft, yd; range 0.1–0.3 m |
| Going (nosing to nosing) | `going` | 260 mm | 10.25 in | mm, cm, m, in, ft, yd; range 0.15–0.4 m |
| Nosing projection | `nosing` | 20 mm | 0.75 in | mm, cm, m, in, ft, yd; range 0–0.05 m |
| Tread thickness | `treadThickness` | 25 mm | 1 in | mm, cm, m, in, ft, yd; range 0.015–0.06 m |
| Risers | `riserBoards` | Closed — riser boards housed too | Closed — riser boards housed too | `closed`, `open` |
| Riser board thickness | `riserThickness` | 12 mm | 0.5 in | mm, cm, m, in, ft, yd; range 0.006–0.03 m |
| Width between the strings | `stairWidth` | 0.86 m | 3 ft | mm, cm, m, in, ft, yd; range 0.5–1.6 m |
| String board depth | `stringerDepth` | 275 mm | 10.75 in | mm, cm, m, in, ft, yd; range 0.15–0.4 m |
| Margin above the nosings | `margin` | 40 mm | 1.5 in | mm, cm, m, in, ft, yd; range 0–0.1 m |
| Trench depth into the string | `trenchDepth` | 12 mm | 0.5 in | mm, cm, m, in, ft, yd; range 0.005–0.025 m |
| Wedge room at the back of each trench | `wedge` | 8 mm | 0.31 in | mm, cm, m, in, ft, yd; range 0–0.02 m |
| Glue blocks per step | `blocksPerStep` | 3 | 3 | range 0–8 |
| Tread and riser board length | `boardStock` | 3.6 m | 12 ft | mm, cm, m, in, ft, yd; range 0.6–6 m |
| Allowance (%) | `wastePercent` | 10 | 10 | range 0–30 |
| Code for the readout | `buildingCode` | US — IRC | US — IRC | `irc`, `uk`, `au`, `ca`, `generic` |

- **Total Rise (floor to floor)**: Finished floor below to finished floor above.
- **Riser You Are Aiming For**: The rise per step you want.
- **Going (nosing to nosing)**: The horizontal step from one nosing to the next.
- **Nosing projection**: How far each tread runs past its riser.
- **Tread thickness**: The tread board.
- **Risers**: Housed riser boards, or open risers.
- **Riser board thickness**: The riser board.
- **Width between the strings**: Clear between the strings' faces.
- **String board depth**: Your board; never recommended here.
- **Margin above the nosings**: String top edge to the pitch line, square to it.
- **Trench depth into the string**: Set on the router.
- **Wedge room at the back of each trench**: The taper the wedges take up.
- **Glue blocks per step**: Your pattern, under each tread.
- **Tread and riser board length**: Each board gives as many treads or risers as fit whole.
- **Allowance (%)**: Spares on treads, risers, wedges and blocks.
- **Code for the readout**: The code the riser and going are read against.

`riserThickness` applies only when `riserBoards` is `closed`.

## The answer on the opening values

Worked exactly as the page works it, on the values each system opens on.

### Metric

| Result | Value |
|---|---|
| **String board length** | 4.6 m |
| Risers | 14 risers |
| Riser height | 185.71 mm |
| Pitch | 35.54 ° |
| Trench to trench along the string | 319.51 mm |
| Throat under the trenches | 38.43 mm |
| Stock length for each string | 4.8 m |
| Tread depth (going + nosing + riser) | 292 mm |
| Tread and riser length | 0.88 m |
| Boards for the treads | 4 boards |
| Boards for the risers | 4 boards |
| Wedges | 60 wedges |
| Glue blocks | 43 blocks |

### US customary

| Result | Value |
|---|---|
| **String board length** | 15.1 ft |
| Risers | 14 risers |
| Riser height | 7.29 in |
| Pitch | 35.41 ° |
| Trench to trench along the string | 12.58 in |
| Throat under the trenches | 1.52 in |
| Stock length for each string | 16 ft |
| Tread depth (going + nosing + riser) | 11.5 in |
| Tread and riser length | 3.08 ft |
| Boards for the treads | 5 boards |
| Boards for the risers | 6 boards |
| Wedges | 60 wedges |
| Glue blocks | 43 blocks |

## How it is worked out

WITHIN THE LIMITS CHECKED — US IRC 2024: riser height 7.31 in (186 mm) and tread depth 10.24 in (260 mm) are inside the limits this calculator checks. That is not a compliance determination: headroom, handrails, guards, nosings and width are not checked, and the building control body or inspector decides.

The working the page shows, in order: Risers; Riser height; Pitch; Trench to trench along the string; Throat under the trenches; Stock length for each string; Tread depth (going + nosing + riser); Tread and riser length; Boards for the treads; Boards for the risers; Wedges; Glue blocks; then string board length.

The method, derived in full:

- [Stair Geometry, Ramps and Guarding](https://craftquantities.com/methodology/stair-geometry-and-guarding/): Why you choose the number of risers rather than their height, why the spread across a whole flight is held to three-eighths of an inch, and why a cable railing has to be checked deflected rather than at rest.

What this calculation does not cover:

- This sets a closed string out; it does not approve the stair. The riser and going are read against your code by the stair rise and run page's own check, and your building official decides.
- The string's board, its fixings to the wall and the trimmer, and the glue and wedges' hold are the joiner's or your engineer's: the board's depth is yours, and the throat shown is geometry, not a strength.
- The trenches are drawn square; the nosing's round is the router cutter's, and the tongue and groove between tread and riser is the joiner's detail.
- The string is cut level on the floor and plumb against the trimmer; a string carried past the first riser to a newel, or eased into a wreath, is set out by the joiner.
- Floor opening and headroom are worked on the stair stringer page for the same riser and going.

A professional must decide:

- This sets a closed string out; it does not approve the stair. The riser and going are read against your code by the stair rise and run page's own check, and your building official decides.
- The string's board, its fixings to the wall and the trimmer, and the glue and wedges' hold are the joiner's or your engineer's: the board's depth is yours, and the throat shown is geometry, not a strength.
- Structure: sizes, thicknesses, spans, reinforcement and bearing are a structural engineer's or the building official's decision. This is a quantity, not a design.

## Sources

As the calculator cites them (sources checked 2026-11-13):

- Riser count as this site's Stair Rise & Run Calculator divides the rise (the total rise over the target riser, rounded); its own code check on the riser and going
- US: IRC R311.7.5 — risers at most 7 3/4 in, treads at least 10 in, as the stair rise and run page reads them; Australia: NCC Housing Provisions Table 11.2.2a; Canada: NBC 9.8.4, a private stair
- Trench spacing along the string = sqrt(going^2 + riser^2); string pitch = atan(riser / going); the margin and throat measured square to the pitch line through the nosings
- UK: Approved Document K (2013 edition), Table 1.1 — a private stair's rise 150–220 mm, going 220–300 mm, pitch at most 42°, 2R + G 550–700 mm <https://assets.publishing.service.gov.uk/media/60d5bdcde90e07716f516cfd/Approved_Document_K.pdf>

The site's pages for the documents these name:

- [International Residential Code](https://craftquantities.com/standards/icc/irc/)
- [Approved Documents to the Building Regulations (England)](https://craftquantities.com/standards/uk-gov/uk-approved-documents/)

A code or standard has force only where a jurisdiction has adopted it, usually with local amendments; check what is in force with the authority where you build.

## Questions answered on the page

**What is the difference between a housed and a cut stringer?**

A cut (open) stringer has notches sawn out of its top edge and the treads sit on them; a housed (closed) string keeps its edge whole and the treads and risers sit in trenches routed into its face, wedged and glued from below.

**Why do the trenches taper?**

The wedge driven in under each tread and behind each riser needs room: the trench widens toward its back by the wedge allowance, so a glued wedge pulls the step tight against the trench's front edge.

**How long a board does each string need?**

The length of its top edge from the floor to the plumb cut at the trimmer: for 13 risers of 200 mm on a 240 mm going with a 275 mm string and a 40 mm margin, about 4.18 m, so a 4.2 m length.

## Related calculators

- [Stair Stringer Calculator (Cuts, Floor Opening, Treads and Risers)](https://craftquantities.com/calculators/materials-quantities/stair-stringer-calculator/)
- [Stair Rise & Run Calculator](https://craftquantities.com/calculators/renovation-construction/stair-calculator/)
- [Winder Stair Calculator (Kite, Balanced and Dancing Winders, Quarter and Half Turns: Each Set Out)](https://craftquantities.com/calculators/materials-quantities/winder-stair-calculator/)
- [Ship's Ladder and Alternating Tread Stair Calculator (Loft and Attic Stairs: Risers, Pitch and Stringers)](https://craftquantities.com/calculators/materials-quantities/ship-ladder-calculator/)

## Run it from a program

- REST: `GET https://api.craftquantities.com/v1/calculate/housed-stringer-calculator` with each input as a query parameter, a length, area or volume with its unit; `https://api.craftquantities.com/v1/describe/housed-stringer-calculator` lists the inputs.
- MCP: the `calculate` tool at https://api.craftquantities.com/mcp with `slug` `housed-stringer-calculator`.
- Definition and test vectors: https://craftquantities.com/api/v1/calculators/housed-stringer-calculator.json

---
Source: https://craftquantities.com/calculators/materials-quantities/housed-stringer-calculator/
Craft Quantities: free to read, cite and link to; the pages are not licensed for republication. Quantities only: no prices, no design and no certification.