# Hip/Valley Rafter Plumb Cut Angular Cutlist

> Calculate hip or valley rafter length and plumb cut angle for a standard 45° hip/valley roof intersection.

Page: https://craftquantities.com/calculators/materials-quantities/hip-valley-rafter-cutlist-calculator/ (calculator). This is the page's Markdown copy; the HTML page is the canonical version.

Version 1.0.1, sources checked 2026-09-02, 2 published test vectors.

Hip/valley rafter length: 19.5 ft for Common Rafter Run 13 ft, the page's opening figures; on the metric page, 4 m gives 6 m. Sources are cited below.

## Inputs

A length, area or volume is entered with its unit. The page opens on the values below: a metric reader sees the metric column, a US customary reader the other.

| Input | id | Opens at (metric) | Opens at (US customary) | Accepts |
|---|---|---|---|---|
| Common Rafter Run (Half Building Width) | `commonRafterRun` | 4 m | 13 ft | mm, cm, m, in, ft, yd; range 0.01–15 m |
| Roof Pitch (rise per 12 run) | `roofPitch` | 6 | 6 | range 1–24 |
| Hip/Valley Member Thickness | `hipThickness` | 45 mm | 1.75 in | mm, cm, m, in, ft, yd; range 0.01–0.3 m |
| Jack Rafter Spacing (on centre) | `jackSpacing` | 400 mm | 16 in | mm, cm, m, in, ft, yd; range 0.1–1.2 m |

- **Common Rafter Run (Half Building Width)**: The horizontal run of a common rafter on this roof — typically half the building width.
- **Roof Pitch (rise per 12 run)**: The roof's slope, expressed as inches of rise per 12 inches of horizontal run.
- **Hip/Valley Member Thickness**: The hip or valley timber's thickness, across its narrow face.
- **Jack Rafter Spacing (on centre)**: The centre-to-centre spacing of the jack rafters framing into the hip or valley.

## The answer on the opening values

Worked exactly as the page works it, on the values each system opens on.

### Metric

| Result | Value |
|---|---|
| **Hip/valley rafter length** | 6 m |
| Plumb cut angle, which is the hip's own inclination | 19.47 ° |
| Cheek bevel, each side of the hip's ridge cut | 43.31 ° |
| Backing bevel on the hip's top edge | 18.43 ° |
| Drop, if the top is left square instead of backed | 0.01 m |
| Jack rafter cheek bevel | 41.81 ° |
| Jack rafters shorten by, each spacing | 0.45 m |

### US customary

| Result | Value |
|---|---|
| **Hip/valley rafter length** | 19.5 ft |
| Plumb cut angle, which is the hip's own inclination | 19.47 ° |
| Cheek bevel, each side of the hip's ridge cut | 43.31 ° |
| Backing bevel on the hip's top edge | 18.43 ° |
| Drop, if the top is left square instead of backed | 0.03 ft |
| Jack rafter cheek bevel | 41.81 ° |
| Jack rafters shorten by, each spacing | 1.49 ft |

## How it is worked out

The working the page shows, in order: Plumb cut angle, which is the hip's own inclination; Cheek bevel, each side of the hip's ridge cut; Backing bevel on the hip's top edge; Drop, if the top is left square instead of backed; Jack rafter cheek bevel; Jack rafters shorten by, each spacing; then hip/valley rafter length.

The method, derived in full:

- [Slope, Pitch and True Surface Area](https://craftquantities.com/methodology/slope-pitch-and-true-area/): Converting a plan footprint into the sloped area a roof actually has — the factor that decides whether a shingle order is right or a third short.

What this calculation does not cover:

- The figure is the theoretical measuring-line length, from the outside corner of the wall plates to the point where the ridge centrelines cross. It deducts nothing for the ridge or the king common rafter the hip butts into, which is half that member's thickness taken on the 45° diagonal, roughly 32 mm off a 45 mm ridge. It also adds no eaves tail, and a hip tail is longer than a common one: a 400 mm horizontal overhang runs about 600 mm along the hip at 6/12, against 450 mm along a common rafter.
- The plumb cut is one angle of a compound one. It is the hip's inclination, arctan((rise/12)/√2) — 19.5° at 6/12 — and it is the setting off a square crosscut; measured against the rafter's top edge the same cut reads as its complement, 70.5°. The cheek bevels are given above and are 45° in PLAN, which is not the angle you set on a saw: the blade figure is arctan(cos θ) taken on the hip's own inclination, 43.3° at 6/12 against the framing square's 43.4°, because the square sets its hip figures out against 17 where the true diagonal is 16.97.
- The backing bevel and the drop above are alternatives, not a sequence: back the top edge to the two roof planes, or leave it square and set the member lower by the drop. Both come from the member thickness entered and nothing else, so a hip of a different thickness needs the figure again. The SEAT is still not produced — it is a compound cut over the corner of two plates rather than the single plumb-and-level birdsmouth of a common rafter, and its geometry depends on how the plates are lapped at that corner, which this page does not ask about.
- The jack figures above are the common difference and the cheek bevel, which is what a set of jacks needs and is not a cut list of them: no jack is counted, none is named, and the first jack's own length depends on where the first spacing falls from the corner, which is a setting-out decision this page does not make. The difference assumes every jack meets the hip at the same 45° in plan and that the spacing is constant — step the spacing anywhere along the run and the arithmetic restarts from that jack.
- No part of this is a structural check. A hip carries the jacks framing into it and a valley collects load from both roof planes, often with a concentrated load where it picks up the minor ridge, so these members are routinely deeper or doubled compared with the commons beside them. The plan run is √2 longer as well, a 4 m (13 ft) common run becoming a 5.66 m (19 ft) diagonal, so common rafter span tables do not apply.

A professional must decide:

- No part of this is a structural check. A hip carries the jacks framing into it and a valley collects load from both roof planes, often with a concentrated load where it picks up the minor ridge, so these members are routinely deeper or doubled compared with the commons beside them.
- Structure: sizes, thicknesses, spans, reinforcement and bearing are a structural engineer's or the building official's decision. This is a quantity, not a design.

## Sources

As the calculator cites them (sources checked 2026-09-02):

- Standard carpentry hip/valley formula: for a 45° plan intersection, hip rafter length = common-rafter run × √(2 + (rise/12)²); plumb cut angle = arctan((rise/12)/√2)
- Compound cuts on an equal-pitch 45° hip: a side cut is arctan(cos θ) taken on that member's own pitch, and the backing bevel is arctan(sin θ) taken on the hip's — both reproduce the rafter tables printed on a framing square, which sets its hip figures out against 17 where the exact diagonal is 12√2 = 16.9706

A code or standard has force only where a jurisdiction has adopted it, usually with local amendments; check what is in force with the authority where you build.

## Questions answered on the page

**Why does the hip/valley formula use √2 instead of the common rafter's √1?**

Because at a standard 45° plan intersection, with equal-pitch roof planes meeting at a corner, the hip or valley rafter runs diagonally in plan and its horizontal run is the common rafter run × √2. The formula assumes that intersection, and that is where the extra factor of 2 (instead of 1) inside the square root comes from.

**What is the plumb cut angle used for?**

Cutting the top end of the hip or valley rafter to meet the ridge or another rafter. It's measured from vertical and is smaller than a common rafter's plumb cut angle because the hip/valley rafter's slope is 'flattened' by its diagonal run.

**Does this apply to unequal-pitch or non-45° hip roofs?**

No — this formula assumes a standard 45° plan intersection where both adjoining roof planes share the same pitch. Irregular hips (different pitches or non-45° plan angles) require a different, more involved layout method.

## Related calculators

- [Common Gable Rafter Length Calculator](https://craftquantities.com/calculators/materials-quantities/common-rafter-length-calculator/)
- [Roof Overhang Tail Length Calculator](https://craftquantities.com/calculators/materials-quantities/roof-overhang-tail-length-calculator/)
- [L-Shaped and T-Shaped Roof Calculator (Area, Ridges, Hips, Valleys, Eaves and Rakes)](https://craftquantities.com/calculators/materials-quantities/hip-valley-roof-calculator/)

## Run it from a program

- REST: `GET https://api.craftquantities.com/v1/calculate/hip-valley-rafter-cutlist-calculator` with each input as a query parameter, a length, area or volume with its unit; `https://api.craftquantities.com/v1/describe/hip-valley-rafter-cutlist-calculator` lists the inputs.
- MCP: the `calculate` tool at https://api.craftquantities.com/mcp with `slug` `hip-valley-rafter-cutlist-calculator`.
- Definition and test vectors: https://craftquantities.com/api/v1/calculators/hip-valley-rafter-cutlist-calculator.json

---
Source: https://craftquantities.com/calculators/materials-quantities/hip-valley-rafter-cutlist-calculator/
Craft Quantities: free to read, cite and link to; the pages are not licensed for republication. Quantities only: no prices, no design and no certification.