# Glulam Beam Deflection Checker

> Check calculated glulam beam deflection against standard L/180 (roof) or L/360 (floor) code limits.

Page: https://craftquantities.com/calculators/materials-quantities/glulam-beam-deflection-calculator/ (calculator). This is the page's Markdown copy; the HTML page is the canonical version.

Version 1.0.1, sources checked 2026-09-05, 2 published test vectors.

Calculated deflection: 0.582 in for Uniform Load 5000 and Moment of Inertia I 500, the page's opening figures, to compare with the limit shown with it; a comparison, not a check. Sources are cited below.

## Inputs

A length, area or volume is entered with its unit. The page opens on the values below: a metric reader sees the metric column, a US customary reader the other.

| Input | id | Opens at (metric) | Opens at (US customary) | Accepts |
|---|---|---|---|---|
| Uniform Load (N/m) | `udl` | 5000 | 5000 | range 100–50000 |
| Span | `span` | 6 m | 19.5 ft | mm, cm, m, in, ft, yd; range 0.01–20 m |
| Modulus of Elasticity E | `elasticModulus` | 11000 MPa | 1595420 psi | pa, kpa, mpa, psi, psf, in_wc; range 5000000000–20000000000 Pa |
| Moment of Inertia I (×10⁶ mm⁴) | `momentOfInertia` | 500 | 500 | range 10–5000 |
| Deflection Limit | `deflectionLimitRatio` | L/360 (floor / plaster ceiling) | L/360 (floor / plaster ceiling) | `180`, `240`, `360` |

- **Uniform Load (N/m)**: The uniformly distributed load along the beam's length.
- **Span**: The beam's clear span between supports.
- **Modulus of Elasticity E**: The glulam's modulus of elasticity, from the manufacturer's grade stamp or design values.
- **Moment of Inertia I (×10⁶ mm⁴)**: The beam cross-section's moment of inertia about the bending axis.
- **Deflection Limit**: The applicable code deflection limit, as a fraction of the span.

## The answer on the opening values

Worked exactly as the page works it, on the values each system opens on.

### Metric

| Result | Value |
|---|---|
| **Calculated deflection** | 15.3 mm |
| Allowable limit | 16.67 mm |

### US customary

| Result | Value |
|---|---|
| **Calculated deflection** | 0.582 in |
| Allowable limit | 0.65 in |

- Confidence: medium.
- The figure is compared against a limit; that is a check of the number, not an approval.

## How it is worked out

The deflection this beam works out to is below the L/360 limit for the span entered shown with it — you entered it from the deflection ratio you chose. Being under one limit is not a design. Nothing else is checked here — not the other limit states, not the connections, not the member the load arrives from.

The working the page shows, in order: Allowable limit; then calculated deflection.

The method, derived in full:

- [Deflection, Creep and Vibration: What Governs a Span](https://craftquantities.com/methodology/deflection-and-vibration/): Why doubling a span multiplies its deflection by sixteen, why a stronger grade of steel does nothing for it, and why a floor that passes every deflection check can still be unacceptable to walk on.

What this calculation does not cover:

- The formula is the simply supported, uniformly loaded case only, Δ = 5wL⁴/(384EI). A cantilever of the same length and load deflects about nine and a half times as much, a beam continuous over a central support roughly two-fifths as much, and a central point load deflects a simple span about 1.6 times as much as the same total load spread evenly, so smearing a post or girder reaction into an equivalent uniform load understates the answer by around a third.
- This is the instantaneous elastic deflection. Timber creeps under sustained load, and the codes deal with it by multiplying the permanent share of the deflection before it is compared with the total-load limit, typically by about 1.5 in (38 mm) dry service and 2.0 when the timber is wet or green, with the exact factor jurisdictional.
- One deflection is compared against one denominator, but a floor is normally required to satisfy two separate checks: live load alone against the tighter limit and dead plus live against the looser one. Nothing on the page can tell which load has been typed in, so an L/360 pass on a total load is merely conservative while an L/240 pass on live load alone is not the floor check any code recognises. Meeting L/360 also says nothing about how a long-span floor feels underfoot, because perceived bounce is a vibration problem governed by frequency and mass rather than by this ratio.
- Only bending deflection is calculated. Shear deformation is left out, and in timber it is not trivial because the shear modulus is roughly one-sixteenth of E: on a deep beam with a span-to-depth ratio below about 15 it can add ten per cent or more. Whether your input already allows for it depends on whether the supplier publishes a true modulus or an apparent one that carries a shear allowance.
- The result is movement from the beam's unloaded shape, not sag below level. Glulam is routinely manufactured with camber, roof beams commonly to something like 1.5 times the dead-load deflection, so the installed beam finishes higher than this figure implies. On a shallow-pitch roof the same deflection is what starts ponding, where water collects in the sag and deepens it, and that feedback loop cannot be represented by a linear elastic formula.
- The moment of inertia is taken as a single constant for the whole span, so a tapered or pitched glulam, a notched end, or a section drilled for services is stiffer on this page than it is on site.

A professional must decide:

- Structure: sizes, thicknesses, spans, reinforcement and bearing are a structural engineer's or the building official's decision. This is a quantity, not a design.

## Sources

As the calculator cites them (sources checked 2026-09-05):

- Uniformly-loaded simple beam deflection: Δ = 5wL⁴/(384EI); standard code deflection limits are L/180 for roof beams and L/360 for floor beams

A code or standard has force only where a jurisdiction has adopted it, usually with local amendments; check what is in force with the authority where you build.

## Questions answered on the page

**Why does deflection depend on span to the fourth power?**

The uniformly-loaded simple beam deflection formula, Δ = 5wL⁴/(384EI), has span (L) raised to the fourth power — so doubling the span increases deflection sixteen-fold for the same load and section, making span by far the most sensitive variable.

**What's the difference between the L/180 and L/360 limits?**

L/360 is the tighter, more common limit for floor beams (and any beam supporting a plaster or rigid ceiling below, which cracks under smaller movements); L/180 is a looser limit typically permitted for roof beams without a plaster ceiling underneath.

**Does passing this deflection check mean the beam is structurally adequate overall?**

No — this checks deflection (serviceability) only. The beam's bending stress and shear capacity must be checked separately against the applied loads to confirm overall structural adequacy.

## Related calculators

- [Timber Beam Bending Stress Calculator](https://craftquantities.com/calculators/materials-quantities/timber-beam-bending-stress-calculator/)
- [Timber Column Euler Buckling Calculator](https://craftquantities.com/calculators/materials-quantities/timber-column-buckling-calculator/)
- [Roof/Floor Deflection Limit Calculator](https://craftquantities.com/calculators/materials-quantities/roof-deflection-limit-calculator/)

## Run it from a program

- REST: `GET https://api.craftquantities.com/v1/calculate/glulam-beam-deflection-calculator` with each input as a query parameter, a length, area or volume with its unit; `https://api.craftquantities.com/v1/describe/glulam-beam-deflection-calculator` lists the inputs.
- MCP: the `calculate` tool at https://api.craftquantities.com/mcp with `slug` `glulam-beam-deflection-calculator`.
- Definition and test vectors: https://craftquantities.com/api/v1/calculators/glulam-beam-deflection-calculator.json

---
Source: https://craftquantities.com/calculators/materials-quantities/glulam-beam-deflection-calculator/
Craft Quantities: free to read, cite and link to; the pages are not licensed for republication. Quantities only: no prices, no design and no certification.