# Footing Soil Bearing Pressure Checker

> Check whether a footing's applied pressure stays within the soil's allowable bearing capacity.

Page: https://craftquantities.com/calculators/materials-quantities/footing-bearing-pressure-calculator/ (calculator). This is the page's Markdown copy; the HTML page is the canonical version.

Version 1.0.1, sources checked 2026-09-06, 2 published test vectors.

Applied bearing pressure: 2,660 psf for Applied Load 112.4 kip, Footing Length 6.5 ft and Footing Width 6.5 ft, the page's opening figures, to compare with the limit shown with it; a comparison, not a check. Sources are cited below.

## Inputs

A length, area or volume is entered with its unit. The page opens on the values below: a metric reader sees the metric column, a US customary reader the other.

| Input | id | Opens at (metric) | Opens at (US customary) | Accepts |
|---|---|---|---|---|
| Applied Load | `appliedLoad` | 500 kN | 112.404 kip | n, kn, lbf, kip; range 10000–20000000 N |
| Footing Length | `footingLength` | 2 m | 6.5 ft | mm, cm, m, in, ft, yd; range 0.01–20 m |
| Footing Width | `footingWidth` | 2 m | 6.5 ft | mm, cm, m, in, ft, yd; range 0.01–20 m |
| Allowable Soil Bearing Pressure | `allowableBearingPressure` | 150 kPa | 3132.82 psf | pa, kpa, mpa, psi, psf, in_wc; range 50000–1000000 Pa |

- **Applied Load**: The total load carried by the footing.
- **Footing Length**: The footing's length in plan.
- **Footing Width**: The footing's width in plan.
- **Allowable Soil Bearing Pressure**: The soil's allowable bearing capacity, from a geotechnical report.

## The answer on the opening values

Worked exactly as the page works it, on the values each system opens on.

### Metric

| Result | Value |
|---|---|
| **Applied bearing pressure** | 125 kN/m² |
| Footing area | 4 m² |
| Allowable bearing pressure | 150 kN/m² |
| Safety margin (allowable / applied) | 1.2 |

### US customary

| Result | Value |
|---|---|
| **Applied bearing pressure** | 2,660 psf |
| Footing area | 42.25 sq ft |
| Allowable bearing pressure | 3,132.82 psf |
| Safety margin (allowable / applied) | 1.18 |

- Confidence: medium.
- The figure is compared against a limit; that is a check of the number, not an approval.

## How it is worked out

The pressure this footing puts on the ground is below the allowable bearing pressure shown with it — you entered it from a geotechnical report. Being under the allowable pressure is not the whole ground question: settlement, groundwater and the footings alongside are all untouched here.

The working the page shows, in order: Footing area; Allowable bearing pressure; Safety margin (allowable / applied); then applied bearing pressure.

The method, derived in full:

- [Bearing Capacity, and How a Load Spreads Into What Carries It](https://craftquantities.com/methodology/bearing-and-load-spread/): Why the allowable pressure under a footing is usually set by settlement rather than by strength, why a wider footing settles more at the same pressure, and why timber bearing is limited by the weakest direction of the grain.

What this calculation does not cover:

- BEARING CAPACITY IS NOT SETTLEMENT. A footing can sit comfortably inside the allowable pressure and still settle more than the structure will tolerate, and on a compressible clay the settlement check is usually the one that governs. Passing here is not permission to stop.
- Assumes the load is concentric and the pressure uniform. Any moment or eccentricity tilts the distribution, and once the resultant leaves the middle third the footing lifts along one edge and the peak pressure climbs far above the average this reports.
- The allowable pressure entered must already carry its geotechnical factor of safety. Entering an ultimate bearing capacity instead over-credits the ground by roughly a factor of three, and nothing here can tell the two apart.
- The footing's own structural design is not checked: punching shear, one-way shear and flexure size the concrete and the reinforcement, and a footing large enough for the ground can still be too thin for the column standing on it.
- Takes no account of adjacent footings whose stress bulbs overlap, of groundwater, of frost depth, or of an excavation planned alongside — each of which can change the allowable pressure without changing anything on this page.

A professional must decide:

- The footing's own structural design is not checked: punching shear, one-way shear and flexure size the concrete and the reinforcement, and a footing large enough for the ground can still be too thin for the column standing on it.
- Structure: sizes, thicknesses, spans, reinforcement and bearing are a structural engineer's or the building official's decision. This is a quantity, not a design.

## Sources

As the calculator cites them (sources checked 2026-09-06):

- Standard geotechnical check: applied bearing pressure = total load / footing area, compared against the site's allowable soil bearing capacity from a geotechnical report

A code or standard has force only where a jurisdiction has adopted it, usually with local amendments; check what is in force with the authority where you build.

## Questions answered on the page

**Where do I get the allowable bearing pressure for my site?**

From a geotechnical (soils) report for your site — it varies enormously by soil type, from under 100 kPa for soft clay to over 400 kPa for dense gravel or rock.

**What does it mean when the pressure comes out above the allowable?**

It means the two figures on this page — the load spread over the footing area you entered, and the allowable pressure from your geotechnical report — fall the wrong way round. That is a comparison, not a determination: this page does not know your soil profile, your settlement criteria, or what else bears nearby. Take both numbers to a structural or geotechnical engineer, who decides what, if anything, changes. This page deliberately does not name a fix, because a footing enlarged on a website's say-so and never checked is a worse outcome than no answer at all.

**Does this account for eccentric loads or overturning moments?**

No — this is a simple uniform-pressure check assuming the load acts through the footing's center. Eccentric loads (like from a retaining wall) need a more detailed pressure-distribution check.

## Related calculators

- [Isolated Spread Footing Sizing Calculator](https://craftquantities.com/calculators/materials-quantities/spread-footing-sizing-calculator/)
- [Continuous Footing / Grade Beam Volume Calculator](https://craftquantities.com/calculators/materials-quantities/continuous-footing-grade-beam-calculator/)

## Run it from a program

- REST: `GET https://api.craftquantities.com/v1/calculate/footing-bearing-pressure-calculator` with each input as a query parameter, a length, area or volume with its unit; `https://api.craftquantities.com/v1/describe/footing-bearing-pressure-calculator` lists the inputs.
- MCP: the `calculate` tool at https://api.craftquantities.com/mcp with `slug` `footing-bearing-pressure-calculator`.
- Definition and test vectors: https://craftquantities.com/api/v1/calculators/footing-bearing-pressure-calculator.json

---
Source: https://craftquantities.com/calculators/materials-quantities/footing-bearing-pressure-calculator/
Craft Quantities: free to read, cite and link to; the pages are not licensed for republication. Quantities only: no prices, no design and no certification.