# Fire-Rated Glazing Typical Edge Clearance Reference

> Look up a typical listed edge clearance (bite) range for common fire-rated glazing and frame type combinations.

Page: https://craftquantities.com/calculators/materials-quantities/fire-rated-glazing-clearance-lookup/ (calculator). This is the page's Markdown copy; the HTML page is the canonical version.

Version 1.0.1, sources checked 2026-09-06, 2 published test vectors.

## Inputs

A length, area or volume is entered with its unit. The page opens on the values below: a metric reader sees the metric column, a US customary reader the other.

| Input | id | Opens at (metric) | Opens at (US customary) | Accepts |
|---|---|---|---|---|
| Fire-Rated Glazing Type | `glazingType` | Traditional wired glass | Traditional wired glass | `wire-glass`, `ceramic`, `multi-ply` |
| Frame Material | `frameType` | Hollow metal | Hollow metal | `hollow-metal`, `aluminum` |

- **Fire-Rated Glazing Type**: The fire-rated glazing product category.
- **Frame Material**: The frame material the glazing is set into.

## The answer on the opening values

Worked exactly as the page works it, on the values each system opens on.

### Metric

| Result | Value |
|---|---|
| **Typical listed edge clearance** | 9.5 mm |

### US customary

| Result | Value |
|---|---|
| **Typical listed edge clearance** | 0.37 in |

- Confidence: low.

## How it is worked out

This is a TYPICAL reference figure only, not a calculated or code-compliant value — fire-rated glazing edge clearance is set entirely by the specific tested and listed assembly (UL 9/UL 10B/UL 10C, NFPA 80/257). Always verify the exact bite/clearance against your specific product's UL listing and the manufacturer's installation instructions before installation; deviating from the tested clearance voids the fire rating.

The method, derived in full:

- [Glass, Insulating Units and the Curtain Wall](https://craftquantities.com/methodology/glazing-and-curtain-wall/): Why glass has no strength until you say how long the load lasts, why the edge of a sealed unit leaks more heat than the middle, and why a mullion's deflection limit protects the seal rather than the glass.

What this calculation does not cover:

- A fire rating is not an impact rating. Glazing in a door, a sidelite or any other hazardous location has to satisfy safety-glazing impact requirements as well, and traditional wired glass is where the two collide — it is weaker under impact than plain annealed glass of the same thickness, and its use in those locations has been restricted for years. Confirm the lite is listed for both before the edge clearance matters at all.
- One figure is returned for every lite size, and listings do not always work that way. A larger lite expands more, so a listing can give a different clearance band for a big lite than for a small one, and this page never asks how big the opening is. Read the size ranges in the listing before treating the figure as fixed.

## Sources

As the calculator cites them (sources checked 2026-09-06):

- Fire-rated glazing edge clearance is NOT governed by a calculable thermal-expansion formula — it is set entirely by the specific tested and listed assembly per UL 9/UL 10B/UL 10C and NFPA 80/257. The values below are commonly-cited TYPICAL figures for reference only.

A code or standard has force only where a jurisdiction has adopted it, usually with local amendments; check what is in force with the authority where you build.

## Questions answered on the page

**Is this edge clearance value calculated from the glass and frame properties?**

No. Fire-rated glazing edge clearance is not governed by a calculable thermal-expansion formula — it is fixed by the specific assembly's UL 9/UL 10B/UL 10C listing and NFPA 80/257 requirements. The figures here are commonly-cited typical values for reference only, not a substitute for the tested listing.

**Can I use this value directly for installation?**

No — always verify the exact bite/clearance required against your specific product's UL listing and the manufacturer's installation instructions before installing. Using a different clearance than what was tested and listed voids the fire rating of the assembly.

**What happens if my exact glazing/frame combination isn't in the table?**

This lookup defaults to the hollow-metal frame value for the selected glazing type when a specific combination isn't listed, but that default is only a rough reference point — the manufacturer's actual listed clearance for your specific frame type must still be confirmed.

**Does the answer change with the fire rating — is a 20-minute lite treated the same as a 90-minute one?**

It is treated the same, and that is the honest limit of this page. Two selections go in and nothing else, so a 20-minute door lite and a 90-minute window come back with the same figure whenever the glazing category and frame material match. Rating duration is what drives the things that actually differ between those two openings: the maximum exposed glass area the listing permits per lite, the glass make-up and thickness, and the frame profile it was tested in. The three glazing options also cut straight across a larger split — fire-protection rated glazing, tested as an opening protective and generally doing nothing about radiant heat coming through the glass, versus fire-resistance rated glazing tested as a wall. Multi-ply intumescent products commonly sit on the second side of that line and ceramics commonly on the first, and this page never asks which one you are holding. There is no design step here waiting to be finished by arithmetic: the figure you build to is printed in the listing for that product at that rating, and on an opening that gets inspected it is the label that gets read.

**The frame options are hollow metal and aluminum — does picking aluminum mean an ordinary storefront frame will do?**

No, and that is the assumption hidden inside the option. Fire-rated aluminum framing is a specific tested product family, and the listed systems are commonly built either as a steel sub-frame wearing aluminum cover caps or as aluminum extrusions filled with a fire-blocking insulating core, because bare aluminum has lost most of its strength long before a furnace test reaches its peak temperatures. A standard commercial storefront extrusion does not become rated by having rated glass set into it, and hollow metal gets no free pass either — the frame has to be a labelled fire-rated frame, not simply a steel one. All the selector does is move the typical figure one step: aluminum returns a smaller figure than hollow metal for the same glass. For two of the three glazing types that step lands on a figure the table already carries — ceramic in aluminum returns what wired glass in hollow metal returns (9.5 mm, restated as 0.37 in when the page is set to imperial), and multi-ply in aluminum returns what ceramic in hollow metal returns. Wired glass in aluminum is the exception: it drops below every other figure on the page rather than landing on one of them. Before any of it matters, confirm the frame carries its own label for the rating you need and that glass and frame are listed together, because a listing commonly pairs one glazing product with one framing system.

**What actually goes wrong with this dimension on site?**

Three things, roughly in this order. The wrong dimension gets used: edge clearance is the gap between the edge of the glass and the back of the glazing pocket, edge cover or bite is how far the stop laps the face of the glass, and face clearance is the gap between the glass face and the stop. Those are three different gaps, and the trade quotes them loosely — bite in particular gets written as though it were another word for edge clearance, which it is not. A listed detail gives them separately and this page hands back one number under one label, so work out which dimension your detail is naming before you compare anything to it. Then the glass gets ordered before the detail is read. Fire-rated ceramic and multi-ply lites are cut at the factory rather than trimmed on the bench, and on a multi-ply product the sealed edge is part of the assembly, so a lite that measures oversize is a re-order and a delay, not a morning's work. Last, the pocket gets filled with whatever is in the van: the setting blocks, glazing tape and compound are named in the listing alongside the glass, and swapping them is the same class of change as swapping the glass. Read the numbers as fractions rather than as precision, too — they are a quarter, three-eighths, a half and five-eighths of an inch converted, and then rounded a second time for display because the page rates its own confidence as low. A result reading 16 mm — or 0.63 in with the page set to imperial — is five-eighths of an inch either way, not a millimetre-accurate requirement.

## Related calculators

- [Blast-Resistant Fenestration Rating Checker](https://craftquantities.com/calculators/materials-quantities/blast-glazing-rating-checker/)
- [Curtain Wall Spandrel Condensation Risk Checker](https://craftquantities.com/calculators/materials-quantities/curtain-wall-condensation-checker/)

## Run it from a program

- REST: `GET https://api.craftquantities.com/v1/calculate/fire-rated-glazing-clearance-lookup` with each input as a query parameter, a length, area or volume with its unit; `https://api.craftquantities.com/v1/describe/fire-rated-glazing-clearance-lookup` lists the inputs.
- MCP: the `calculate` tool at https://api.craftquantities.com/mcp with `slug` `fire-rated-glazing-clearance-lookup`.
- Definition and test vectors: https://craftquantities.com/api/v1/calculators/fire-rated-glazing-clearance-lookup.json

---
Source: https://craftquantities.com/calculators/materials-quantities/fire-rated-glazing-clearance-lookup/
Craft Quantities: free to read, cite and link to; the pages are not licensed for republication. Quantities only: no prices, no design and no certification.