# External Stepped Access Calculator (Approved Document M)

> Steps, flights and landings for an external stepped approach from the rise it climbs, each step's rise and going set beside Approved Document M's ranges.

Page: https://craftquantities.com/calculators/materials-quantities/external-stepped-access-calculator/ (calculator). This is the page's Markdown copy; the HTML page is the canonical version.

Version 1.0.0, sources checked 2026-09-22, 6 published test vectors.

Risers in the stepped approach: 6 risers for Total Rise of the Approach 3 ft, Largest Step Rise You Want 6.25 in and Going of Each Step 11.75 in, the page's opening figures, to compare with the limit shown with it; a comparison, not a check. Sources are cited below.

## Inputs

A length, area or volume is entered with its unit. The page opens on the values below: a metric reader sees the metric column, a US customary reader the other.

| Input | id | Opens at (metric) | Opens at (US customary) | Accepts |
|---|---|---|---|---|
| Total Rise of the Approach | `totalRise` | 0.9 m | 3 ft | mm, cm, m, in, ft, yd; range 0.05–10 m |
| Largest Step Rise You Want | `maxRise` | 160 mm | 6.25 in | mm, cm, m, in, ft, yd; range 0.1–0.22 m |
| Going of Each Step | `going` | 300 mm | 11.75 in | mm, cm, m, in, ft, yd; range 0.2–0.5 m |

- **Total Rise of the Approach**: The whole height the steps climb, from the lower level to the upper.
- **Largest Step Rise You Want**: The steps are made no taller than this, in as few equal steps as that allows.
- **Going of Each Step**: The depth of each tread, nosing to nosing.

## The answer on the opening values

Worked exactly as the page works it, on the values each system opens on.

### Metric

| Result | Value |
|---|---|
| **Risers in the stepped approach** | 6 risers |
| Rise of each step | 150 mm |
| Lowest rise Approved Document M gives for external steps | 150 mm |
| Highest rise it gives | 170 mm |
| Going of each step | 300 mm |
| Most risers in one flight at this going | 12 risers |
| Flights | 1 flight |
| Treads | 5 treads |
| Level landings, top, bottom and between | 2 landings |
| Each landing, at least | 1.2 m |
| Horizontal length, landings included | 3.9 m |

### US customary

| Result | Value |
|---|---|
| **Risers in the stepped approach** | 6 risers |
| Rise of each step | 6 in |
| Lowest rise Approved Document M gives for external steps | 5.91 in |
| Highest rise it gives | 6.69 in |
| Going of each step | 11.75 in |
| Most risers in one flight at this going | 12 risers |
| Flights | 1 flight |
| Treads | 5 treads |
| Level landings, top, bottom and between | 2 landings |
| Each landing, at least | 3.94 ft |
| Horizontal length, landings included | 12.77 ft |

- Confidence: medium.
- The figure is compared against a limit; that is a check of the number, not an approval.

## How it is worked out

The rise divides into 6 equal steps in 1 flight of no more than 12 risers each. Each step's rise is within the range Approved Document M gives, and its going is within its range. Being inside the ranges is not a finding that the steps are safe to use: the nosings, handrails, hazard-warning surface, width and landings each have their own requirement.

The working the page shows, in order: Rise of each step; Lowest rise Approved Document M gives for external steps; Highest rise it gives; Going of each step; Most risers in one flight at this going; Flights; Treads; Level landings, top, bottom and between; Each landing, at least; Horizontal length, landings included; then risers in the stepped approach.

The method, derived in full:

- [Accessible Approaches: Ramps, Doors and Steps](https://craftquantities.com/methodology/accessible-approaches/): Why Approved Document M ties a ramp's gradient to its length, why a ramp over 300 mm needs steps beside it and one over 2 m a lift, why a door's width is not its leaf, and why an external step has a range rather than a figure.

What this calculation does not cover:

- Straight flights with landings of the minimum length. A landing where the steps turn, or where a door opens onto it, needs more room.
- External steps only. Internal stairs in buildings other than dwellings follow Approved Document K's rules for a general access stair, and have their own calculator on this site.
- It does not check the nosings, the hazard-warning surface, the handrails, the width or whether the rises are closed — all separate requirements of the same paragraph.

## Sources

As the calculator cites them (sources checked 2026-09-22):

- Approved Document M Volume 2, para 1.33: the rise of each step between 150 mm and 170 mm and the going between 280 mm and 425 mm, consistent throughout a flight; no more than 12 risers in a flight for a going under 350 mm and no more than 18 for a going of 350 mm or more; a level landing at the top and bottom of each flight at least 1200 mm long; no single steps; flights at least 1.2 m wide; no open risers; contrasting nosings 55 mm wide; handrails on both sides

The site's pages for the documents these name:

- [Approved Documents to the Building Regulations (England)](https://craftquantities.com/standards/uk-gov/uk-approved-documents/)

A code or standard has force only where a jurisdiction has adopted it, usually with local amendments; check what is in force with the authority where you build.

## Questions answered on the page

**What rise and going does Approved Document M ask for?**

On external steps to buildings other than dwellings, a rise of 150 to 170 mm (about 5⅞ to 6¾ in) and a going of 280 to 425 mm (about 11 to 16¾ in), the same on every step of a flight. For schools it prefers a rise of 150 mm (about 5⅞ in) and a going of 280 mm (about 11 in).

**How many steps can one flight have?**

Twelve risers where the going is under 350 mm (about 13¾ in), and eighteen where it is 350 mm or more, because deeper treads make a longer flight easier to climb. A longer rise is split into flights with a level landing at least 1200 mm (about 3 ft 11 in) long between them.

**Why are single steps not allowed?**

Because a single step is easy to miss. A flight of two or more is seen as a change in level; one step on its own is a trip hazard, especially for people with impaired sight. Where the change in level is too small for two steps, a ramp is the answer.

**Does this apply to the stairs inside a building?**

No. This is Approved Document M's rule for external stepped access. Stairs inside buildings other than dwellings are designed to Approved Document K's rules for a general access stair, and stairs in houses to its rules for a private stair; the stair calculator on this site covers those.

## Related calculators

- [Accessible Ramp Flights and Landings Calculator (Approved Document M)](https://craftquantities.com/calculators/materials-quantities/accessible-ramp-flights-landings-calculator/)
- [Stair Rise & Run Calculator](https://craftquantities.com/calculators/renovation-construction/stair-calculator/)
- [Door Effective Clear Width Calculator (Approved Document M and ADA)](https://craftquantities.com/calculators/materials-quantities/door-effective-clear-width-calculator/)
- [Commercial ADA Accessible Ramp Length & Landing Calculator](https://craftquantities.com/calculators/materials-quantities/ada-ramp-length-calculator/)

## Run it from a program

- REST: `GET https://api.craftquantities.com/v1/calculate/external-stepped-access-calculator` with each input as a query parameter, a length, area or volume with its unit; `https://api.craftquantities.com/v1/describe/external-stepped-access-calculator` lists the inputs.
- MCP: the `calculate` tool at https://api.craftquantities.com/mcp with `slug` `external-stepped-access-calculator`.
- Definition and test vectors: https://craftquantities.com/api/v1/calculators/external-stepped-access-calculator.json

---
Source: https://craftquantities.com/calculators/materials-quantities/external-stepped-access-calculator/
Craft Quantities: free to read, cite and link to; the pages are not licensed for republication. Quantities only: no prices, no design and no certification.