Equivalent round duct diameter: 10.7 in for Rectangular Duct Side A 12 in and Rectangular Duct Side B 8 in, the page's opening figures; on the metric page, 304.8 mm and 203.2 mm give 271 mm. Sources are cited below.

## Inputs

A length, area or volume is entered with its unit. The page opens on the values below: a metric reader sees the metric column, a US customary reader the other.

| Input | id | Opens at (metric) | Opens at (US customary) | Accepts |
|---|---|---|---|---|
| Rectangular Duct Side A | `sideA` | 304.8 mm | 12 in | mm, cm, m, in, ft, yd; range 0.01–1.524 m |
| Rectangular Duct Side B | `sideB` | 203.2 mm | 8 in | mm, cm, m, in, ft, yd; range 0.01–1.524 m |

- **Rectangular Duct Side A**: One side length of the rectangular duct cross-section.
- **Rectangular Duct Side B**: The other side length of the rectangular duct cross-section.

## The answer on the opening values

Worked exactly as the page works it, on the values each system opens on.

### Metric

| Result | Value |
|---|---|
| **Equivalent round duct diameter** | 271 mm |

### US customary

| Result | Value |
|---|---|
| **Equivalent round duct diameter** | 10.7 in |

## How it is worked out

The method, derived in full:

- [Head Loss, Falls and Surge: Resistance in Pipes, Ducts and Drains](https://craftquantities.com/methodology/head-loss-falls-and-surge/): Why one pipe size up cuts the friction to a third, why a compressed flex duct can cost four times its rated loss, why a drain can be too steep, and why a fast-closing valve produces a pressure the pump never could.

What this calculation does not cover:

- The diameter that comes back is a clear internal bore. Internal acoustic lining takes it from both sides, so 25 mm (1 in) of liner means ordering roughly 50 mm (2 in) larger outside to keep the airflow, and flexible duct and duct board are rougher than the smooth galvanized steel the equation was fitted to — a flex run has to be larger again.
- Converts a size without checking it. If the rectangular duct was already undersized and running fast and noisy, the equivalent round comes back equally undersized: the equation matches friction loss between two shapes, it never says the friction loss was acceptable in the first place.
- Does not ask whether the round duct will physically go in. Ducts are rectangular because the space is shallow, and the equivalent diameter always exceeds the short side it replaces — a 300 x 150 duct works out near 230 mm (9 in) round, which no longer fits the ceiling void that forced the rectangle.

## Sources

As the calculator cites them (sources checked 2026-09-06):

- Huebscher equivalent diameter equation: De = 1.30 × (a×b)^0.625 ÷ (a+b)^0.25, where a and b are the rectangular duct's side lengths (inches) and De is the equivalent round duct diameter (inches) — the standard ASHRAE-cited method for converting between rectangular and round duct sizes at equal airflow and friction loss.

A code or standard has force only where a jurisdiction has adopted it, usually with local amendments; check what is in force with the authority where you build.

## Questions answered on the page

**What is the Huebscher equation used for?**

It converts a rectangular duct's cross-sectional dimensions into the diameter of a round duct that delivers equivalent airflow capacity and friction loss — the standard ASHRAE-cited method for comparing or substituting between rectangular and round duct sizes.

**Does the equivalent diameter equal the rectangular duct's average side length?**

No — the Huebscher equation accounts for the different way air friction scales with duct shape, so the equivalent round diameter is generally smaller than a simple average of the two rectangular sides.

**Can I use this to size a round duct replacing an existing rectangular duct?**

Yes — it gives the round duct diameter that matches the rectangular duct's airflow capacity and friction loss at the same air velocity, which is the standard approach when substituting duct shapes in a system.

## Related calculators

- [HVAC Duct Size Calculator](https://craftquantities.com/calculators/plumbing-hvac/hvac-duct-cfm-calculator/)
- [HVAC Duct Fitting Equivalent Length Calculator](https://craftquantities.com/calculators/materials-quantities/duct-fitting-equivalent-length-calculator/)

## Run it from a program

- REST: `GET https://api.craftquantities.com/v1/calculate/equivalent-round-duct-diameter-calculator` with each input as a query parameter, a length, area or volume with its unit; `https://api.craftquantities.com/v1/describe/equivalent-round-duct-diameter-calculator` lists the inputs.
- MCP: the `calculate` tool at https://api.craftquantities.com/mcp with `slug` `equivalent-round-duct-diameter-calculator`.
- Definition and test vectors: https://craftquantities.com/api/v1/calculators/equivalent-round-duct-diameter-calculator.json

---
Source: https://craftquantities.com/calculators/materials-quantities/equivalent-round-duct-diameter-calculator/
Craft Quantities: free to read, cite and link to; the pages are not licensed for republication. Quantities only: no prices, no design and no certification.