# ADA Door Maneuvering Clearance Calculator

> The landing a door needs on the side you are standing, set by the direction of approach and by whether the door is being pushed or pulled.

Page: https://craftquantities.com/calculators/materials-quantities/door-maneuvering-clearance-calculator/ (calculator). This is the page's Markdown copy; the HTML page is the canonical version.

Version 1.0.0, sources checked 2026-08-30, 3 published test vectors.

Required clear depth at the door: 60 in for Clear Opening Width 32 in, the page's opening figures; on the metric page, 812.8 mm gives 1,524 mm. Sources are cited below.

## Inputs

A length, area or volume is entered with its unit. The page opens on the values below: a metric reader sees the metric column, a US customary reader the other.

| Input | id | Opens at (metric) | Opens at (US customary) | Accepts |
|---|---|---|---|---|
| Approach Direction | `approach` | From the front, square on to the door | From the front, square on to the door | `front`, `hinge`, `latch` |
| Side of the Door | `side` | Pull side — the door swings toward you | Pull side — the door swings toward you | `pull`, `push` |
| Door Closer Fitted | `hasCloser` | No closer | No closer | `no`, `yes` |
| Latch Fitted | `hasLatch` | Latch fitted | Latch fitted | `yes`, `no` |
| Hinge-Side Pull Arrangement | `hingeOption` | Deeper space, less width alongside | Deeper space, less width alongside | `deep`, `wide` |
| Clear Opening Width | `clearOpeningWidth` | 812.8 mm | 32 in | mm, cm, m, in, ft, yd; range 0.7–1.8 m |

- **Approach Direction**: The direction someone arrives at the door from in a wheelchair.
- **Side of the Door**: Whether the door swings toward the person or away from them.
- **Door Closer Fitted**: Whether the door has a self-closing device.
- **Latch Fitted**: Whether the door has a latch that must be released to open it.
- **Hinge-Side Pull Arrangement**: Which of the two permitted hinge-side pull arrangements you are building to.
- **Clear Opening Width**: The clear width through the doorway with the door open ninety degrees.

`hingeOption` applies only when `approach` is `hinge`.

## The answer on the opening values

Worked exactly as the page works it, on the values each system opens on.

### Metric

| Result | Value |
|---|---|
| **Required clear depth at the door** | 1,524 mm |
| Clear space required alongside the doorway | 457.2 mm |
| Total clear width of the maneuvering space | 1,270 mm |
| Minimum clear opening width at the door | 812.8 mm |

### US customary

| Result | Value |
|---|---|
| **Required clear depth at the door** | 60 in |
| Clear space required alongside the doorway | 18 in |
| Total clear width of the maneuvering space | 50 in |
| Minimum clear opening width at the door | 32 in |

## How it is worked out

The clear opening entered is at or above the 32 in minimum. The space alongside is measured beyond the latch side for front and latch approaches; for a hinge-side approach, check the figure in 404.2.4.1 for which jamb it is taken from before setting out. The maneuvering space must be level, within a slope of 1:48 in any direction, and must be clear of the door's own swing. Matching the figures quoted is not compliance. The rest of the requirement, and the installed work, are outside what this page can see.

The working the page shows, in order: Clear space required alongside the doorway; Total clear width of the maneuvering space; Minimum clear opening width at the door; then required clear depth at the door.

The method, derived in full:

- [Clearances, Layout and Accessibility Dimensions](https://craftquantities.com/methodology/clearances-layout-and-accessibility/): Why an accessible dimension is a measured anthropometric result rather than a round number, why a parking layout is set by the vehicle that turns worst, and why a door needs floor space on the side nobody draws.

What this calculation does not cover:

- Manual swinging doors and gates only. Sliding, folding, automatic and power-assisted doors are covered by different provisions, and doorways without doors different again.
- Does not cover doors in series, recessed doors, or the additional clearance a recess deeper than 8 in (203 mm) imposes on the approach.
- Says nothing about opening force, closing speed or hardware operability, which are separate requirements a compliant landing does not satisfy on its own.

## Sources

As the calculator cites them (sources checked 2026-08-30):

- 2010 ADA Standards for Accessible Design, section 404.2.4.1 and Table 404.2.4.1, maneuvering clearances at manual swinging doors and gates
- ICC A117.1, Accessible and Usable Buildings and Facilities, carries an equivalent table; confirm which document your jurisdiction has adopted, since editions differ in places
- 2010 ADA Standards 404.2.3 sets the minimum clear opening width at 32 in with the door open ninety degrees, and 404.2.4.4 requires the maneuvering space floor to be level within a slope of 1:48

A code or standard has force only where a jurisdiction has adopted it, usually with local amendments; check what is in force with the authority where you build.

## Questions answered on the page

**Why does the pull side need so much more room than the push side?**

Because the person has to get out of the way of the door they are opening. On the pull side a wheelchair user reaches the handle, draws the leaf toward themselves, and must then reverse and travel around the arc the door sweeps before going through. On the push side the door moves away and the user follows it, so the space needed is close to the depth of the chair itself.

**Does the maneuvering space have to be level?**

Yes — the standard allows a slope of no more than 1:48 in any direction across it, which is a drainage fall rather than a usable gradient. This is the detail that most often defeats a door at the head of a ramp: the landing is the right size on plan, but it has been given the ramp's own fall, and the user cannot hold position while working the door.

**The door has no latch. Does that change anything?**

It does, on two cases. The front push and hinge push clearances grow only where a door has both a closer and a latch, because that combination requires the user to release the latch and overcome the closer at the same time. A push-plate door with a closer and no latch stays at the smaller dimension.

**Can the door swing into the maneuvering space?**

No. The space has to be clear of the leaf's arc through its full travel, which is what makes a door in a corridor recess so difficult: the clearance and the swing compete for the same floor. Where the geometry will not resolve, the usual answers are to rehang the door, change the hand, or fit a power operator and take the door out of the equation.

## Related calculators

- [Commercial ADA Accessible Ramp Length & Landing Calculator](https://craftquantities.com/calculators/materials-quantities/ada-ramp-length-calculator/)
- [ADA Ramp Handrail Extension Calculator](https://craftquantities.com/calculators/materials-quantities/ada-ramp-handrail-extension-calculator/)
- [Spiral Stair Headroom Clearance Calculator](https://craftquantities.com/calculators/materials-quantities/spiral-stair-headroom-calculator/)

## Run it from a program

- REST: `GET https://api.craftquantities.com/v1/calculate/door-maneuvering-clearance-calculator` with each input as a query parameter, a length, area or volume with its unit; `https://api.craftquantities.com/v1/describe/door-maneuvering-clearance-calculator` lists the inputs.
- MCP: the `calculate` tool at https://api.craftquantities.com/mcp with `slug` `door-maneuvering-clearance-calculator`.
- Definition and test vectors: https://craftquantities.com/api/v1/calculators/door-maneuvering-clearance-calculator.json

---
Source: https://craftquantities.com/calculators/materials-quantities/door-maneuvering-clearance-calculator/
Craft Quantities: free to read, cite and link to; the pages are not licensed for republication. Quantities only: no prices, no design and no certification.