# Door Effective Clear Width Calculator (Approved Document M and ADA)

> Set a door's measured clear width beside the minimum Approved Document M's Table 2 or the ADA Standards give, and see the room to spare or the shortfall.

Page: https://craftquantities.com/calculators/materials-quantities/door-effective-clear-width-calculator/ (calculator). This is the page's Markdown copy; the HTML page is the canonical version.

Version 1.0.0, sources checked 2026-09-22, 8 published test vectors.

Measured width as a share of the minimum: 103 % for Measured Clear Width 33 in, the page's opening figures, to compare with the limit shown with it; a comparison, not a check. Sources are cited below.

## Inputs

A length, area or volume is entered with its unit. The page opens on the values below: a metric reader sees the metric column, a US customary reader the other.

| Input | id | Opens at (metric) | Opens at (US customary) | Accepts |
|---|---|---|---|---|
| Rule to Compare Against | `rule` | 2010 ADA Standards (United States) | 2010 ADA Standards (United States) | `adm`, `ada` |
| Building | `building` | New building | New building | `new`, `existing` |
| How the Door Is Approached | `approach` | Straight on, with no turn | Straight on, with no turn | `straight`, `right-1500`, `right-1200`, `external` |
| Depth of the Opening | `deep` | 24 in (610 mm) deep or less | 24 in (610 mm) deep or less | `no`, `yes` |
| Measured Clear Width | `width` | 830 mm | 33 in | mm, cm, m, in, ft, yd; range 0.3–3 m |

- **Rule to Compare Against**: Which document's minimum the width is set beside.
- **Building**: Approved Document M gives existing buildings slightly smaller minimums.
- **How the Door Is Approached**: The row of Table 2 the door falls under.
- **Depth of the Opening**: A deep opening is harder to steer through, so the ADA asks more of it.
- **Measured Clear Width**: The clear opening, measured the way the chosen rule measures it.

`building` applies only when `rule` is `adm`.
`approach` applies only when `rule` is `adm`.
`deep` applies only when `rule` is `ada`.

## The answer on the opening values

Worked exactly as the page works it, on the values each system opens on.

### Metric

| Result | Value |
|---|---|
| **Measured width as a share of the minimum** | 102 % |
| Minimum effective clear width for this door | 812.8 mm |
| Measured clear width | 830 mm |
| Room to spare over the minimum | 17.2 mm |

### US customary

| Result | Value |
|---|---|
| **Measured width as a share of the minimum** | 103 % |
| Minimum effective clear width for this door | 32 in |
| Measured clear width | 33 in |
| Room to spare over the minimum | 1 in |

- Confidence: medium.
- The figure is compared against a limit; that is a check of the number, not an approval.

## How it is worked out

The measured width is 102% of the minimum the 2010 ADA Standards give a door opening. A width at or over the minimum is not a finding that the doorway is usable: the space to approach it, the clear space beside the leading edge, the force needed to open it and the threshold each have their own requirement.

The working the page shows, in order: Minimum effective clear width for this door; Measured clear width; Room to spare over the minimum; then measured width as a share of the minimum.

The method, derived in full:

- [Accessible Approaches: Ramps, Doors and Steps](https://craftquantities.com/methodology/accessible-approaches/): Why Approved Document M ties a ramp's gradient to its length, why a ramp over 300 mm needs steps beside it and one over 2 m a lift, why a door's width is not its leaf, and why an external step has a range rather than a figure.

What this calculation does not cover:

- It compares one measurement with one minimum. Whether the door is measured the way the rule measures it — past the handle, the weather board and the stop — decides whether the comparison means anything.
- The two rules measure differently: Approved Document M from the stop on the closing side to the furthest projection on the hinge side, the ADA from the face of the open door to the stop. A reading taken one way does not transfer to the other.
- Approved Document M's opening-force limits, the manoeuvring space beside the door and the threshold are separate requirements; the ADA's manoeuvring clearances have their own calculator on this site.

## Sources

As the calculator cites them (sources checked 2026-09-22):

- Approved Document M Volume 2, Table 2, Minimum effective clear widths of doors (new / existing buildings): straight-on 800 / 750 mm; at right angles to an access route at least 1500 mm wide 800 / 750 mm; at right angles to an access route at least 1200 mm wide 825 / 775 mm; external doors to buildings used by the general public 1000 / 775 mm — measured at right angles to the wall from the outside of the door stop on the closing side to any obstruction on the hinge side (Diagram 9)
- 2010 ADA Standards for Accessible Design, 404.2.3: door openings shall provide a clear width of 32 inches (815 mm) minimum, measured between the face of the door and the stop with the door open 90 degrees; openings more than 24 inches (610 mm) deep shall provide 36 inches (915 mm) minimum

The site's pages for the documents these name:

- [Approved Documents to the Building Regulations (England)](https://craftquantities.com/standards/uk-gov/uk-approved-documents/)

A code or standard has force only where a jurisdiction has adopted it, usually with local amendments; check what is in force with the authority where you build.

## Questions answered on the page

**What is the effective clear width?**

The width a wheelchair can actually pass through, which is always less than the door leaf. Approved Document M measures it at right angles to the wall, from the door stop on the closing side to whatever projects furthest on the hinge side — the open door itself, a handle or a weather board. The stop, the thickness of the open leaf and any handle on the hinge side all take width away, so the leaf size in a catalogue is not the figure to compare: measure the hung door.

**Why does the approach change the minimum?**

Because turning into a doorway takes more width than rolling straight through it. Approved Document M asks 800 mm (about 31½ in) for a straight-on approach or a turn from a route at least 1500 mm (about 4 ft 11 in) wide, 825 mm (about 32½ in) for a turn from a route only 1200 mm (about 3 ft 11 in) wide, and 1000 mm (about 39⅜ in) for the external door of a public building, where people arrive with pushchairs, luggage and companions.

**How does the ADA measure a door?**

Between the face of the door and the stop, with the door open 90 degrees, and it asks for 32 in (815 mm) minimum — 36 in (915 mm) where the opening is more than 24 in (610 mm) deep. Nothing may project into that width below 34 in (865 mm) above the floor, and between 34 and 80 in (865 and 2030 mm) projections are limited to 4 in (100 mm).

**Does a wide enough door make the doorway accessible?**

No. The width is one requirement among several: the clear space beside the leading edge of the door, the force needed to open it, the threshold, the vision panels and the space to approach it all matter, and a door that is wide enough but needs two hands and a strong push to open is not usable by many people. The clear width is the one requirement this page compares.

## Related calculators

- [ADA Door Maneuvering Clearance Calculator](https://craftquantities.com/calculators/materials-quantities/door-maneuvering-clearance-calculator/)
- [Wheelchair Turning Space Clearance Checker](https://craftquantities.com/calculators/materials-quantities/wheelchair-turning-space-calculator/)
- [Accessible Ramp Flights and Landings Calculator (Approved Document M)](https://craftquantities.com/calculators/materials-quantities/accessible-ramp-flights-landings-calculator/)
- [Commercial Revolving Door Vestibule Footprint Calculator](https://craftquantities.com/calculators/materials-quantities/revolving-door-footprint-calculator/)

## Run it from a program

- REST: `GET https://api.craftquantities.com/v1/calculate/door-effective-clear-width-calculator` with each input as a query parameter, a length, area or volume with its unit; `https://api.craftquantities.com/v1/describe/door-effective-clear-width-calculator` lists the inputs.
- MCP: the `calculate` tool at https://api.craftquantities.com/mcp with `slug` `door-effective-clear-width-calculator`.
- Definition and test vectors: https://craftquantities.com/api/v1/calculators/door-effective-clear-width-calculator.json

---
Source: https://craftquantities.com/calculators/materials-quantities/door-effective-clear-width-calculator/
Craft Quantities: free to read, cite and link to; the pages are not licensed for republication. Quantities only: no prices, no design and no certification.