# Dew Point and Relative Humidity Calculator (with the Coating Surface Check)

> Dew point and humidity, with the margin above the dew point that Wattyl's and Tnemec's coating data sheets set: three Celsius (five Fahrenheit) degrees.

Page: https://craftquantities.com/calculators/materials-quantities/dew-point-calculator/ (calculator). This is the page's Markdown copy; the HTML page is the canonical version.

Version 1.0.0, sources checked 2026-10-05, 5 published test vectors.

Answer: 53.6 °F for Air Temperature 68 °F, the page's opening figures; on the metric page, 20 °C gives 12 °C. Sources are cited below.

## Inputs

A length, area or volume is entered with its unit. The page opens on the values below: a metric reader sees the metric column, a US customary reader the other.

| Input | id | Opens at (metric) | Opens at (US customary) | Accepts |
|---|---|---|---|---|
| Work Out | `solveFor` | The dew point, from the air temperature and relative humidity | The dew point, from the air temperature and relative humidity | `dewPoint`, `relativeHumidity`, `airTemperature` |
| Air Temperature | `airTemperature` | 20 °C | 68 °F | c, f, k; range -40–60 °C |
| Relative Humidity (%) | `relativeHumidity` | 60 | 60 | range 1–100 |
| Air Temperature (with a Known Dew Point) | `rhAirTemperature` | 20 °C | 68 °F | c, f, k; range -40–60 °C |
| Dew Point | `rhDewPoint` | 12 °C | 53.6 °F | c, f, k; range -45–60 °C |
| Dew Point (to Find the Air Temperature) | `knownDewPoint` | 12 °C | 53.6 °F | c, f, k; range -45–60 °C |
| Relative Humidity (%, to Find the Air Temperature) | `knownHumidity` | 60 | 60 | range 1–100 |
| Surface Temperature (for the Coating Check) | `surfaceTemperature` | 18 °C | 64.4 °F | c, f, k; range -40–80 °C |
| Margin Above the Dew Point the Coating Asks For | `coatingMargin` | 3 °C | 5 °F | c_delta, f_delta; range 0–15 °C |

- **Work Out**: Any one of the three from the other two.
- **Air Temperature**: The dry-bulb temperature of the air where the work is.
- **Relative Humidity (%)**: The hygrometer's reading, in %, taken with the air temperature.
- **Air Temperature (with a Known Dew Point)**: The dry-bulb temperature of the air.
- **Dew Point**: The dew point of the same air, read from a dew point instrument or a weather station.
- **Dew Point (to Find the Air Temperature)**: The dew point of the air.
- **Relative Humidity (%, to Find the Air Temperature)**: The relative humidity, in %.
- **Surface Temperature (for the Coating Check)**: The temperature of the surface to be coated, measured on the surface itself.
- **Margin Above the Dew Point the Coating Asks For**: How far above the dew point the surface has to be, from the coating's data sheet: three Celsius (five Fahrenheit) degrees on Wattyl's and Tnemec's.

`airTemperature` applies only when `solveFor` is `dewPoint`.
`relativeHumidity` applies only when `solveFor` is `dewPoint`.
`rhAirTemperature` applies only when `solveFor` is `relativeHumidity`.
`rhDewPoint` applies only when `solveFor` is `relativeHumidity`.
`knownDewPoint` applies only when `solveFor` is `airTemperature`.
`knownHumidity` applies only when `solveFor` is `airTemperature`.

## The answer on the opening values

Worked exactly as the page works it, on the values each system opens on.

### Metric

| Result | Value |
|---|---|
| **Answer** | 12 °C |
| Dew point | 12 °C |
| Air temperature | 20 °C |
| Relative humidity | 60 % |
| Air temperature above the dew point | 8 Δ°C |
| Surface temperature above the dew point | 6 Δ°C |
| Lowest surface temperature the coating check asks for | 15 °C |

### US customary

| Result | Value |
|---|---|
| **Answer** | 53.6 °F |
| Dew point | 53.59 °F |
| Air temperature | 68 °F |
| Relative humidity | 60 % |
| Air temperature above the dew point | 14.41 Δ°F |
| Surface temperature above the dew point | 10.81 Δ°F |
| Lowest surface temperature the coating check asks for | 58.59 °F |

## How it is worked out

The surface stands above the dew point by at least the margin entered, at these readings. That is one condition of a coating's data sheet, not all of them: its own limits on humidity and on air and surface temperature apply as well, the readings move through the day, and the decision to coat is the applicator's.

The working the page shows, in order: Dew point; Air temperature; Relative humidity; Air temperature above the dew point; Surface temperature above the dew point; Lowest surface temperature the coating check asks for; then answer.

The method, derived in full:

- [Airtightness, Infiltration and Moisture](https://craftquantities.com/methodology/airtightness-and-infiltration/): Why a blower-door result is not an air change rate, why a leak at the top of a house matters far more than the same leak halfway up, and why sealing without ventilating moves the problem rather than solving it.

What this calculation does not cover:

- Below freezing this is the dew point over water, the temperature at which supercooled dew would form. Frost forms at the frost point over ice, a little higher, which the WMO works with different constants; a surface below freezing collects frost before this figure says it would collect dew.
- The air reading and the surface reading have to be taken together, where the work is. The air next to a cold steel wall, inside a tank or under a slab is not the air at the door, and a surface in the sun, in shade or against cold ground can sit several degrees from the air around it. A contact thermometer on the surface itself, not an air probe held near it, is what the surface figure should come from.
- Conditions move. The dew point rises as the evening cools the air towards it and falls as a dry wind comes through; a reading that clears the margin at noon may not clear it at dusk, while the coating is still curing. Coating makers ask for the checks to be repeated through the work and during the cure.
- The margin is one condition of a coating's data sheet, not all of them. A product's sheet can also set its own lowest and highest air and surface temperatures and a highest relative humidity, and some products need a lowest humidity to cure; the product's own sheet governs, and the decision to coat is the applicator's.
- The formula is the WMO's Magnus form for water from −45 to 60 °C (−49 to 140 °F), with an uncertainty of up to 0.6% in the vapour pressure, which is about a tenth of a Celsius degree (two tenths of a Fahrenheit degree) in the dew point. Outside that range the figure is shown but marked, because the coefficients were not fitted there.

## Sources

As the calculator cites them (sources checked 2026-10-05):

- WMO, Guide to Instruments and Methods of Observation (WMO-No. 8), Volume I (2023 edition), Annex 4.B, Formulae for the computation of measures of humidity: e_w(t) = 6.112 exp\[17.62 t / (243.12 + t)\], water (pure phase), −45 °C to +60 °C, uncertainty up to 0.6% (k = 2); over ice 6.112 exp\[22.46 t / (272.62 + t)\], −65 °C to 0 °C. Read as the WMO reproduces the annex in its own training unit, Calibration of humidity instruments, Part 1 <https://etrp.wmo.int/pluginfile.php/97653/mod_folder/content/0/Training%20Material/5_1_Humidity%20Part%201%20Introduction.pdf>
- Algebra of the Magnus form with b = 17.62 and c = 243.12 °C, since relative humidity is the vapour pressure over the saturation pressure at the air temperature: dew point Td = cγ / (b − γ) with γ = ln(RH/100) + bT / (c + T); RH = 100 exp(bTd / (c + Td) − bT / (c + T)); air temperature T = cδ / (b − δ) with δ = bTd / (c + Td) − ln(RH/100)
- Wattyl (Valspar Paint (Australia) Pty Ltd), Protective & Marine InfoSheet I-05, Ambient Application Conditions (Version 6, March 2021): to allow a safety margin, normally the substrate temperature must be at least 3 °C above the dew point; most coatings have an upper limit of 85% relative humidity; worked example: 16 °C at 71% relative humidity gives a dew point of 11 °C, and a substrate at 13 °C is only 2 °C above it, so painting should not proceed <https://info.wattyl.com.au/Content/Docs/P&M_20210615_InfoSheets_I-05%20AMBIENT%20APPLICATION%20CONDITIONS.pdf>
- Tnemec, Application Guide SS-5.0 to SS-5.2 (Propolymer and Vinester special systems), 3.3 Dehumidification: the surface should be clean, dry and contaminant free, and be at least 5°F (3°C) above the dew point; do not apply when humidity exceeds 80% <https://www.tnemec.com/documents/1952/App_Guide_SS-5.0_to_SS-5.2_Propolymer__Vinester_Special_Systems.pdf>
- ISO 8502-4:2017, Preparation of steel substrates before application of paints and related products — Tests for the assessment of surface cleanliness — Part 4: Guidance on the estimation of the probability of condensation prior to paint application (published 9 January 2017), as the Standards Council of Canada records it: it "gives guidance on the estimation of the probability of condensation on a surface to be painted" and "may be used to establish whether conditions at the job site are suitable for painting or not". The standard's text is not reproduced here, and no figure on this page is taken from it <https://ccn-scc.ca/standardsdb/standards/8157907>

A code or standard has force only where a jurisdiction has adopted it, usually with local amendments; check what is in force with the authority where you build.

## Questions answered on the page

**What is the dew point?**

The temperature to which air has to cool, holding the same moisture, for that moisture to start condensing. Any surface colder than the air's dew point collects water out of it: the cold can, the window on a winter morning, the steel tank in the evening. The further the air temperature is above the dew point, the drier the air; at 100% relative humidity the two are equal.

**How is the dew point worked out from temperature and humidity?**

By the Magnus formula, with the constants the WMO's Guide to Instruments and Methods of Observation gives for water: b = 17.62 and c = 243.12, with every temperature in degrees Celsius. Take γ = ln(RH/100) + bT/(c + T); the dew point is cγ/(b − γ). For air at 20 °C (68 °F) and 60% that is 12.0 °C (53.6 °F). The same constants run backwards give the humidity from a dew point, or the air temperature. The WMO gives them for −45 to 60 °C (−49 to 140 °F), with up to 0.6% uncertainty in the vapour pressure, about a tenth of a Celsius degree (two tenths of a Fahrenheit degree) in the dew point.

**How far above the dew point must a surface be before coating?**

At least three Celsius (five Fahrenheit) degrees on the two data sheets this page quotes. Wattyl's application conditions sheet asks for the substrate to be at least three Celsius degrees above the dew point, and Tnemec's guide for at least five Fahrenheit degrees, written beside three Celsius. Wattyl's own worked example: air at 16 °C (60.8 °F) and 71% has a dew point of about 11 °C (51.8 °F), so a substrate at 13 °C (55.4 °F) is only about two Celsius degrees above it, and the sheet says painting should not proceed. The page works that example's dew point as 10.7 °C (51.3 °F). Your product's own data sheet has the margin and the humidity limits that apply to it.

**Why does the surface temperature matter more than the air temperature?**

Because condensation forms on the surface, and a surface is often colder than the air beside it: steel that cooled overnight, a slab on cold ground, a wall in shade. Air at 20 °C (68 °F) and 60% has a dew point of 12 °C (53.6 °F), so the air itself is eight Celsius (14.4 Fahrenheit) degrees above its dew point and nowhere near condensing; steel at 14 °C (57.2 °F) in it is only two Celsius (3.6 Fahrenheit) degrees above the dew point, inside the margin of three Celsius (five Fahrenheit) degrees.

**Is this the same dew point the vapor barrier page asks for?**

Yes. The Vapor Barrier Dew-Point Condensation Risk Calculator and the Curtain Wall Spandrel Condensation Risk Checker both ask for the interior air's dew point and compare a temperature inside the wall with it; this page works that dew point out from the room's temperature and humidity, so the two can be used one after the other.

## Related calculators

- [Vapor Barrier Dew-Point Condensation Risk Calculator](https://craftquantities.com/calculators/materials-quantities/vapor-barrier-dewpoint-calculator/)
- [Curtain Wall Spandrel Condensation Risk Checker](https://craftquantities.com/calculators/materials-quantities/curtain-wall-condensation-checker/)
- [Dehumidifier Water Removal Calculator](https://craftquantities.com/calculators/plumbing-hvac/dehumidifier-pulldown-calculator/)
- [Concrete Evaporation Rate Calculator](https://craftquantities.com/calculators/materials-quantities/concrete-evaporation-calculator/)
- [Two-Pack Paint and Coating Mixing Calculator — Pot Life and Batch Size](https://craftquantities.com/calculators/materials-quantities/two-pack-paint-mixing-calculator/)

## Run it from a program

- REST: `GET https://api.craftquantities.com/v1/calculate/dew-point-calculator` with each input as a query parameter, a length, area or volume with its unit; `https://api.craftquantities.com/v1/describe/dew-point-calculator` lists the inputs.
- MCP: the `calculate` tool at https://api.craftquantities.com/mcp with `slug` `dew-point-calculator`.
- Definition and test vectors: https://craftquantities.com/api/v1/calculators/dew-point-calculator.json

---
Source: https://craftquantities.com/calculators/materials-quantities/dew-point-calculator/
Craft Quantities: free to read, cite and link to; the pages are not licensed for republication. Quantities only: no prices, no design and no certification.