# Corrugated Metal Panel Side Lap Overlap Calculator

> Calculate how many corrugated metal panels are needed to cover a roof width, accounting for side lap overlap.

Page: https://craftquantities.com/calculators/materials-quantities/corrugated-panel-overlap-calculator/ (calculator). This is the page's Markdown copy; the HTML page is the canonical version.

Version 1.0.1, sources checked 2026-09-06, 2 published test vectors.

Panels needed: 20 panels for Total Roof Width 66 ft, Panel Width 3.5 ft and Side Lap Width 2 in, the page's opening figures; on the metric page, 20 m, 1.05 m and 50 mm give 20 panels. Sources are cited below.

## Inputs

A length, area or volume is entered with its unit. The page opens on the values below: a metric reader sees the metric column, a US customary reader the other.

| Input | id | Opens at (metric) | Opens at (US customary) | Accepts |
|---|---|---|---|---|
| Total Roof Width | `roofWidth` | 20 m | 66 ft | mm, cm, m, in, ft, yd; range 0.01–100 m |
| Panel Width (Out-to-Out) | `panelWidth` | 1.05 m | 3.5 ft | mm, cm, m, in, ft, yd; range 0.01–2 m |
| Side Lap Width | `sideLapWidth` | 50 mm | 2 in | mm, cm, m, in, ft, yd; range 0.01–0.3 m |

- **Total Roof Width**: The total width of roof to be covered, measured across the panel runs.
- **Panel Width (Out-to-Out)**: The panel's full out-to-out width, before accounting for overlap.
- **Side Lap Width**: How much of each panel's width overlaps the adjacent panel along its side lap.

## The answer on the opening values

Worked exactly as the page works it, on the values each system opens on.

### Metric

| Result | Value |
|---|---|
| **Panels needed** | 20 panels |
| Net coverage width per panel | 1 m |

### US customary

| Result | Value |
|---|---|
| **Panels needed** | 20 panels |
| Net coverage width per panel | 3.33 ft |

## How it is worked out

The working the page shows, in order: Net coverage width per panel; then panels needed.

The method, derived in full:

- [Rolls, Sheets and the Lap Between Them](https://craftquantities.com/methodology/rolls-sheets-and-laps/): Why covering an area with rolls is a strip count rather than a division, why the lap is bought twice over, and why turning the strips the other way can change the order.

What this calculation does not cover:

- How many panels is settled here; which panel is not. Gauge and profile depth are chosen against the purlin spacing and the wind and snow the sheet has to carry between supports, so the same count in a thinner or shallower profile deflects between purlins, holds water at the laps and oil-cans in the flats.

A professional must decide:

- Electrics: circuit design, protection, cable sizing and the work itself are for a qualified or licensed electrician, under the rules where you build.

## Sources

As the calculator cites them (sources checked 2026-09-06):

- Net coverage width per panel = panel width − side lap width; panels needed = ceil(total roof width ÷ net coverage width per panel)

A code or standard has force only where a jurisdiction has adopted it, usually with local amendments; check what is in force with the authority where you build.

## Questions answered on the page

**Why does a shallower roof need more overlap, not less?**

Because water climbs. On a steep roof a lap sheds almost immediately; as the pitch flattens, rain driven by wind travels UP the sheet against gravity, and it will get past a short end lap and run out on the inside. So the end lap grows as the pitch falls, and below the profile maker’s minimum pitch no lap length is enough and the joint has to be sealed or the sheet run in one unbroken length. The side lap behaves differently again: it is measured in whole RIBS rather than in millimetres, because the sheets only nest where the profile repeats, so the material lost sideways comes in fixed steps and a half-rib of extra cover is not available to be bought.

**Why subtract the side lap width from the panel's full width?**

Each panel overlaps the next one along its side lap, so only the net (non-overlapped) width actually adds new coverage across the roof — using the full out-to-out panel width would undercount how many panels are needed.

**Does this calculation also cover end lap overlap?**

No — this calculator only accounts for side lap overlap across the roof width. If a panel run is longer than one available sheet length, the end lap needed to join sheets end-to-end is a separate calculation not included here.

**What happens if I enter a side lap width of 0?**

The net coverage width becomes equal to the full panel width, which is the same as assuming no overlap between adjacent panels — this will understate the number of panels an overlapped installation actually needs.

## Related calculators

- [Standing Seam Metal Roof Clip Count Calculator](https://craftquantities.com/calculators/materials-quantities/standing-seam-clip-count-calculator/)
- [Geotextile Riprap Fabric Overlap Calculator](https://craftquantities.com/calculators/heavy-civil/geotextile-riprap-overlap-calculator/)

## Run it from a program

- REST: `GET https://api.craftquantities.com/v1/calculate/corrugated-panel-overlap-calculator` with each input as a query parameter, a length, area or volume with its unit; `https://api.craftquantities.com/v1/describe/corrugated-panel-overlap-calculator` lists the inputs.
- MCP: the `calculate` tool at https://api.craftquantities.com/mcp with `slug` `corrugated-panel-overlap-calculator`.
- Definition and test vectors: https://craftquantities.com/api/v1/calculators/corrugated-panel-overlap-calculator.json

---
Source: https://craftquantities.com/calculators/materials-quantities/corrugated-panel-overlap-calculator/
Craft Quantities: free to read, cite and link to; the pages are not licensed for republication. Quantities only: no prices, no design and no certification.