# Concrete Slump Flow Test Calculator (ASTM C1611)

> Classify a self-consolidating concrete (SCC) mix's flowability and viscosity from a slump flow test reading.

Page: https://craftquantities.com/calculators/materials-quantities/concrete-slump-flow-calculator/ (calculator). This is the page's Markdown copy; the HTML page is the canonical version.

Version 1.0.1, sources checked 2026-09-06, 2 published test vectors.

Average slump flow: 26.5 in for Spread Diameter 1 27 in and Spread Diameter 2 26 in, the page's opening figures; on the metric page, 680 mm and 670 mm give 675 mm. Sources are cited below.

## Inputs

A length, area or volume is entered with its unit. The page opens on the values below: a metric reader sees the metric column, a US customary reader the other.

| Input | id | Opens at (metric) | Opens at (US customary) | Accepts |
|---|---|---|---|---|
| Spread Diameter 1 | `diameter1` | 680 mm | 27 in | mm, cm, m, in, ft, yd; range 0.3–0.9 m |
| Spread Diameter 2 | `diameter2` | 670 mm | 26 in | mm, cm, m, in, ft, yd; range 0.3–0.9 m |
| T50 Spread Time | `t50Seconds` | 3 | 3 | range 0.5–10 |

- **Spread Diameter 1**: The first of two perpendicular spread diameter measurements.
- **Spread Diameter 2**: The second perpendicular spread diameter measurement.
- **T50 Spread Time**: The time in seconds for the concrete to reach the marked spread circle.

## The answer on the opening values

Worked exactly as the page works it, on the values each system opens on.

### Metric

| Result | Value |
|---|---|
| **Average slump flow** | 675 mm |
| Diameter spread between the two readings | 10 mm |
| T50 spread time | 3 s |

### US customary

| Result | Value |
|---|---|
| **Average slump flow** | 26.5 in |
| Diameter spread between the two readings | 1 in |
| T50 spread time | 3 s |

## How it is worked out

Flowability class: SF2. Viscosity class: VS2 (more viscous, better segregation resistance).

The working the page shows, in order: Diameter spread between the two readings; T50 spread time; then average slump flow.

The method, derived in full:

- [Concrete Mix Design and Fresh-Concrete Behaviour](https://craftquantities.com/methodology/concrete-mix-and-fresh-behaviour/): Why a litre of water added on site costs strength permanently, why yield is the sum of absolute volumes rather than of loose ones, and why strength is a function of temperature and time together rather than of age.

What this calculation does not cover:

- The two readings are averaged whatever the gap between them. ASTM C1611 treats a difference of more than 50mm between the perpendicular diameters as grounds to discard that test and repeat it, so a 700/620mm pair is not a 660mm SF2 mix — it is a test that has not yet produced a usable number, and this page lowers its confidence rather than withholding the average.
- Flowability is not passing ability. A mix can spread to SF2 or SF3 on an open base plate and still arch and block between closely spaced bars, which is why passing ability is measured separately with a J-Ring (ASTM C1621) or an L-box, comparing an obstructed spread against this free one. Nothing entered here describes bar spacing, cover or maximum aggregate size.
- T50 describes how the mix behaves while it is still moving, not whether it stays uniform once it stops. Static segregation — coarse aggregate settling through a deep lift, a mortar-rich layer forming at the top — is judged by a column or sieve segregation test and by the visual stability rating of the patty, none of which this page calculates, so an SF2/VS2 pair is not by itself evidence of a stable mix.
- The viscosity class is a hard cut at exactly 2 seconds, and T50 is hand-timed from the cone clearing the concrete to the spread first touching the 500mm circle. Half a second of operator variation moves a mix from VS1 to VS2, so readings either side of 2s are one borderline band rather than two different mixes.
- A flow class is a target chosen for a particular element, not a grade to be maximised, and it says nothing about what the mix does to the formwork. SF3 is specified for heavily congested or complex sections rather than being an improvement on SF1, and self-consolidating concrete of any class can act on the form at close to full hydrostatic pressure, which is a separate calculation from anything on this page.

A professional must decide:

- Structure: sizes, thicknesses, spans, reinforcement and bearing are a structural engineer's or the building official's decision. This is a quantity, not a design.

## Sources

As the calculator cites them (sources checked 2026-09-06):

- ASTM C1611 slump flow test procedure and EFNARC/ACI SF1-SF2-SF3 flowability classes (SF1: 550-650mm, SF2: 651-750mm, SF3: 751-850mm) and VS1/VS2 viscosity classes based on the T50 spread time (VS1 ≤ 2s, VS2 > 2s)

A code or standard has force only where a jurisdiction has adopted it, usually with local amendments; check what is in force with the authority where you build.

## Questions answered on the page

**What does the slump flow diameter tell me?**

It's a direct measure of the mix's flowability under its own weight — larger spread means a more flowable mix, useful for congested reinforcement or complex formwork, but excessive spread can also signal segregation.

**Why does T50 (spread time) matter separately from the final diameter?**

Two mixes can reach the same final spread diameter at very different speeds — T50 measures viscosity, which affects how the mix behaves while filling formwork and how much time workers have before it locks in place.

**What is a Visual Stability Index (VSI)?**

A separate 0-3 visual rating (not calculated here) for segregation signs like a mortar halo around the patty's edge or coarse aggregate piling at the center — always inspect the actual test patty, since numbers alone don't catch every segregation sign.

## Related calculators

- [SCC Formwork Lateral Pressure Calculator](https://craftquantities.com/calculators/materials-quantities/scc-formwork-pressure-calculator/)
- [Concrete Calculator](https://craftquantities.com/calculators/materials-quantities/concrete-calculator/)

## Run it from a program

- REST: `GET https://api.craftquantities.com/v1/calculate/concrete-slump-flow-calculator` with each input as a query parameter, a length, area or volume with its unit; `https://api.craftquantities.com/v1/describe/concrete-slump-flow-calculator` lists the inputs.
- MCP: the `calculate` tool at https://api.craftquantities.com/mcp with `slug` `concrete-slump-flow-calculator`.
- Definition and test vectors: https://craftquantities.com/api/v1/calculators/concrete-slump-flow-calculator.json

---
Source: https://craftquantities.com/calculators/materials-quantities/concrete-slump-flow-calculator/
Craft Quantities: free to read, cite and link to; the pages are not licensed for republication. Quantities only: no prices, no design and no certification.