# ACI 347 Column Formwork Pressure Calculator

> Calculate the maximum lateral pressure on column formwork from ordinary (non-SCC) concrete, using the ACI 347R rate-of-placement formula.

Page: https://craftquantities.com/calculators/materials-quantities/column-formwork-pressure-calculator/ (calculator). This is the page's Markdown copy; the HTML page is the canonical version.

Version 1.2.2, sources checked 2026-10-31, 2 published test vectors.

Maximum lateral formwork pressure: 1,440 psf for Concrete Unit Weight 150 pcf, Concrete Temperature 70 °F and Total Column Pour Height 10 ft, the page's opening figures; on the metric page, 2402.77 kg/m³, 21.1 °C and 3 m give 68.8 kPa. Sources are cited below.

## Inputs

A length, area or volume is entered with its unit. The page opens on the values below: a metric reader sees the metric column, a US customary reader the other.

| Input | id | Opens at (metric) | Opens at (US customary) | Accepts |
|---|---|---|---|---|
| Concrete Unit Weight | `freshDensity` | 2402.77 kg/m³ | 150 pcf | kgm3, pcf, lbyd3; range 1602–3204 kg/m³ |
| Rate of Placement R (ft/hr) | `pourRate` | 10 | 10 | range 1–40 |
| Concrete Temperature | `concreteTemperature` | 21.1 °C | 70 °F | c, f, k; range 4–38 °C |
| Cement/Admixture Coefficient Cc (1.0 = Ordinary Cement No Retarder; 1.2 = With Retarder OR High Slag/Fly-Ash No Retarder; 1.4 = High Slag/Fly-Ash WITH Retarder) | `cementCoefficient` | 1.0 — Ordinary Cement, No Retarder | 1.0 — Ordinary Cement, No Retarder | `1.0`, `1.2`, `1.4` |
| Total Column Pour Height | `columnHeight` | 3 m | 10 ft | mm, cm, m, in, ft, yd; range 0.01–12 m |

- **Concrete Unit Weight**: The fresh concrete's unit weight.
- **Rate of Placement R (ft/hr)**: How fast the concrete surface rises in the column form, in feet per hour.
- **Concrete Temperature**: The temperature of the fresh concrete at placement, in °F.
- **Cement/Admixture Coefficient Cc (1.0 = Ordinary Cement No Retarder; 1.2 = With Retarder OR High Slag/Fly-Ash No Retarder; 1.4 = High Slag/Fly-Ash WITH Retarder)**: ACI 347R Table 2.2 chemistry coefficient for the cement/admixture combination used.
- **Total Column Pour Height**: The total vertical height of the column being poured.

## The answer on the opening values

Worked exactly as the page works it, on the values each system opens on.

### Metric

| Result | Value |
|---|---|
| **Maximum lateral formwork pressure** | 68.8 kPa |
| Unit weight coefficient Cw | 1 (dimensionless) |
| Full hydrostatic ceiling | 70.69 kPa |

### US customary

| Result | Value |
|---|---|
| **Maximum lateral formwork pressure** | 1,440 psf |
| Unit weight coefficient Cw | 1 (dimensionless) |
| Full hydrostatic ceiling | 1,500 psf |

- Confidence: medium.

## How it is worked out

Column forms are frequently filled faster than the concrete below can stiffen, so full hydrostatic pressure is a realistic design case rather than a conservative one. That is the main way columns differ from walls.

The working the page shows, in order: Unit weight coefficient Cw; Full hydrostatic ceiling; then maximum lateral formwork pressure.

The method, derived in full:

- [Formwork Pressure](https://craftquantities.com/methodology/formwork-pressure/): Why a column form sees full hydrostatic pressure and a wall form usually does not, and why temperature belongs in the equation.

What this calculation does not cover:

- Assumes the concrete behaves as a fluid to the depth given. Where the pour rate is slow enough for the lower concrete to stiffen, the pressure envelope is lower — but relying on that requires knowing the rate and the temperature.
- Excludes the lateral loads from placing, from vibration and from wind on the form, all of which act alongside the concrete pressure.
- Retarding admixtures, low temperature and high slump all extend the time the concrete stays fluid and therefore raise the pressure that develops.

A professional must decide:

- Structure: sizes, thicknesses, spans, reinforcement and bearing are a structural engineer's or the building official's decision. This is a quantity, not a design.

## Sources

As the calculator cites them (sources checked 2026-10-31):

- ACI 347R-14(21) Guide to Formwork for Concrete, Section 2.2.2, Eq. 2.2 (for forms where no plan dimension exceeds 6.5 ft/2m, i.e. columns): Pmax = Cw×Cc×\[150 + 9000R/T\] psf, with a floor of 600×Cw psf and a ceiling of full hydrostatic pressure (w×h) — this equation has no stated upper rate-of-placement limit in the Guide (unlike the wall equation's 15 ft/hr cap), reflecting that column forms are typically filled quickly enough that the full-hydrostatic ceiling governs naturally at high rates. Cw and Cc coefficients are identical to and defined the same way as this site's companion wall formwork pressure calculator. This formula ONLY applies when slump ≤7in and normal internal vibration to ≤4ft depth is used — SCC and high-slump/retarded mixes must use this site's full-hydrostatic SCC formwork pressure calculator instead.

The site's pages for the documents these name:

- [ACI 347R](https://craftquantities.com/standards/aci/aci-347r/)

A code or standard has force only where a jurisdiction has adopted it, usually with local amendments; check what is in force with the authority where you build.

## Questions answered on the page

**Why do columns see higher pressure than walls?**

Because of pour rate. A column is a small plan area filled in minutes, so the concrete at the bottom is still fluid when the top arrives — the full height acts hydrostatically. A wall of the same height is filled over a much longer period, and its lower concrete stiffens and starts carrying itself before the pour finishes. The geometry is the same; the timing is not.

**Does a slower pour reduce the pressure?**

Yes, and it is the most effective control available. Pressure depends on how much of the concrete is still fluid, so slowing the rate lets the lower lifts stiffen and cap the pressure envelope well below hydrostatic. It costs programme time, and on a tall column it is often cheaper than the formwork needed to resist a full hydrostatic head.

**What makes the concrete stay fluid longer?**

Cold weather, retarding admixtures, high slump, and high cement replacement with GGBS or fly ash. Every one of these extends the working time, which is usually the intention — and every one raises the formwork pressure as a side effect. A mix changed for placeability without telling the formwork designer is a recognised route to a blowout.

**Does vibration increase the pressure?**

Yes. Vibrating re-liquefies concrete that had begun to stiffen, undoing the pressure relief that time was providing, and deep immersion of the poker does it several lifts down. Formwork design assumes normal internal vibration; prolonged or excessively deep vibration takes the pressure back toward hydrostatic.

**When does a form count as a column?**

In ACI 347R's terms, when no plan dimension exceeds 6.5 ft (2 m). A vertical element with one side longer than that is a wall, and the wall equations apply instead, changing with the rate of placement and the depth of the pour. A blade pier 400 mm by 2.4 m (16 in by 8 ft) is a wall by that definition however it is drawn on the structural plans.

**Is there a lowest pressure the formula will give?**

Yes. The column equation is never taken below 600 × Cw psf — 600 psf, about 28.7 kPa, for normal-weight concrete — however slow the pour or warm the day, and never above the full hydrostatic pressure of the height placed. A result on that floor means the formula gave less for the rate and temperature entered, and the floor, not the formula, is the design pressure.

## Related calculators

- [ACI 347 Wall Formwork Rate-of-Placement Pressure Calculator](https://craftquantities.com/calculators/materials-quantities/wall-formwork-pressure-calculator/)
- [SCC Formwork Lateral Pressure Calculator](https://craftquantities.com/calculators/materials-quantities/scc-formwork-pressure-calculator/)

## Run it from a program

- REST: `GET https://api.craftquantities.com/v1/calculate/column-formwork-pressure-calculator` with each input as a query parameter, a length, area or volume with its unit; `https://api.craftquantities.com/v1/describe/column-formwork-pressure-calculator` lists the inputs.
- MCP: the `calculate` tool at https://api.craftquantities.com/mcp with `slug` `column-formwork-pressure-calculator`.
- Definition and test vectors: https://craftquantities.com/api/v1/calculators/column-formwork-pressure-calculator.json

---
Source: https://craftquantities.com/calculators/materials-quantities/column-formwork-pressure-calculator/
Craft Quantities: free to read, cite and link to; the pages are not licensed for republication. Quantities only: no prices, no design and no certification.