# Fireplace/Chimney Chase Framing Clearance Calculator

> Calculate the required chase opening dimensions around a chimney or flue, based on the appliance's clearance-to-combustibles requirement.

Page: https://craftquantities.com/calculators/materials-quantities/chimney-chase-clearance-calculator/ (calculator). This is the page's Markdown copy; the HTML page is the canonical version.

Version 1.0.1, sources checked 2026-09-06, 2 published test vectors.

Required chase opening area: 3.89 sq ft for Chimney/Flue Width 2 ft, Chimney/Flue Depth 16 in and Required Clearance-to-Combustibles 2 in, the page's opening figures; on the metric page, 0.6 m, 400 mm and 50 mm give 0.35 m². Sources are cited below.

## Inputs

A length, area or volume is entered with its unit. The page opens on the values below: a metric reader sees the metric column, a US customary reader the other.

| Input | id | Opens at (metric) | Opens at (US customary) | Accepts |
|---|---|---|---|---|
| Chimney/Flue Width | `chimneyWidth` | 0.6 m | 2 ft | mm, cm, m, in, ft, yd; range 0.01–1.5 m |
| Chimney/Flue Depth | `chimneyDepth` | 400 mm | 16 in | mm, cm, m, in, ft, yd; range 0.01–1.5 m |
| Required Clearance-to-Combustibles (per Manufacturer's Listing) | `requiredClearance` | 50 mm | 2 in | mm, cm, m, in, ft, yd; range 0.01–0.6 m |

- **Chimney/Flue Width**: The width of the chimney or flue assembly itself.
- **Chimney/Flue Depth**: The depth of the chimney or flue assembly itself.
- **Required Clearance-to-Combustibles (per Manufacturer's Listing)**: The minimum clearance from the chimney/flue to any combustible framing, per the manufacturer's listing.

## The answer on the opening values

Worked exactly as the page works it, on the values each system opens on.

### Metric

| Result | Value |
|---|---|
| **Required chase opening area** | 0.35 m² |
| Chase opening width | 0.7 m |
| Chase opening depth | 0.5 m |

### US customary

| Result | Value |
|---|---|
| **Required chase opening area** | 3.89 sq ft |
| Chase opening width | 2.33 ft |
| Chase opening depth | 1.67 ft |

- Confidence: medium.

## How it is worked out

Clearance-to-combustibles is appliance- and chimney-system-specific per the manufacturer's listing and the applicable fuel gas/mechanical code (NFPA 211 governs solid-fuel chimneys) — always use the exact clearance from your specific unit's installation instructions, never an assumed value.

The working the page shows, in order: Chase opening width; Chase opening depth; then required chase opening area.

The method, derived in full:

- [Masonry Units, Coursing and the Things That Support Them](https://craftquantities.com/methodology/masonry-units-coursing-and-support/): Why a brick's working size is the unit plus its joint, why a dry brick ruins the mortar bond, and why a veneer's shelf angle is governed by eccentricity rather than by weight.

What this calculation does not cover:

- The airspace this opening creates has to stay empty for the life of the chase. It is the ventilated gap that keeps framing below its ignition temperature, so blowing attic insulation across it, or packing mineral wool into it because the chase feels cold, voids the very listing the clearance figure came from — the opening measures right and the framing still chars.
- Nothing here firestops the chase. Where it passes a floor or ceiling the gap around the chimney has to be closed at each level with the material the listing names, usually sheet metal or a listed firestop spacer, and a chase left open top to bottom is a vertical shaft that takes a basement fire into the attic in minutes.
- Flue termination height is a separate rule this page does not reach: the chimney has to finish at least 3 ft (0.91 m) above the roof where it passes through and 2 ft (0.61 m) above anything within 10 ft (3 m) of it. A chase framed to exactly the right clearance around a flue that stops short still pushes smoke back into the room every time the wind swings.

A professional must decide:

- Gas: pipe sizing, appliance connection and testing are for a registered or licensed gas fitter.

## Sources

As the calculator cites them (sources checked 2026-09-06):

- Chase opening width/depth = Chimney/Flue Width or Depth + 2 × Required Clearance-to-Combustibles — clearance-to-combustibles is always specified by the specific appliance or chimney system manufacturer's listing (per NFPA 211 and the applicable mechanical/fuel gas code), and varies significantly by appliance type and chimney system; this calculator applies the clearance value you supply.

A code or standard has force only where a jurisdiction has adopted it, usually with local amendments; check what is in force with the authority where you build.

## Questions answered on the page

**Why is the clearance added twice to each dimension?**

The required clearance-to-combustibles applies on every side of the chimney or flue, so it is added once on each side of both the width and the depth — doubling the single-side value for each dimension.

**Where do I find the required clearance-to-combustibles value?**

It is appliance- and chimney-system-specific, set by the manufacturer's listing and the applicable fuel gas/mechanical code (NFPA 211 governs solid-fuel chimneys) — always use the exact figure from your specific unit's installation instructions rather than an assumed value.

**Does this account for the chase's exterior finish material thickness?**

No — this calculates the required rough framing opening around the chimney/flue based on clearance-to-combustibles only. Add the finish material thickness separately when detailing the overall chase dimensions.

## Related calculators

- [Appliance Combustion Air Free Area Calculator (Indoor Air Method)](https://craftquantities.com/calculators/materials-quantities/combustion-air-free-area-calculator/)
- [Built-In Bench/Planter Seat Wall Concrete Volume Calculator](https://craftquantities.com/calculators/materials-quantities/seat-wall-concrete-volume-calculator/)

## Run it from a program

- REST: `GET https://api.craftquantities.com/v1/calculate/chimney-chase-clearance-calculator` with each input as a query parameter, a length, area or volume with its unit; `https://api.craftquantities.com/v1/describe/chimney-chase-clearance-calculator` lists the inputs.
- MCP: the `calculate` tool at https://api.craftquantities.com/mcp with `slug` `chimney-chase-clearance-calculator`.
- Definition and test vectors: https://craftquantities.com/api/v1/calculators/chimney-chase-clearance-calculator.json

---
Source: https://craftquantities.com/calculators/materials-quantities/chimney-chase-clearance-calculator/
Craft Quantities: free to read, cite and link to; the pages are not licensed for republication. Quantities only: no prices, no design and no certification.