# Cold-Formed Steel (CFS) C-Stud Deflection Checker

> Check a cold-formed steel stud's calculated lateral (wind) deflection against a code deflection limit.

Page: https://craftquantities.com/calculators/materials-quantities/cfs-stud-deflection-calculator/ (calculator). This is the page's Markdown copy; the HTML page is the canonical version.

Version 1.0.1, sources checked 2026-09-05, 3 published test vectors.

Calculated stud deflection: 0.0332 in for Uniform Lateral (Wind) Load 300 and Effective Moment of Inertia I_eff 2, the page's opening figures, to compare with the limit shown with it; a comparison, not a check. Sources are cited below.

## Inputs

A length, area or volume is entered with its unit. The page opens on the values below: a metric reader sees the metric column, a US customary reader the other.

| Input | id | Opens at (metric) | Opens at (US customary) | Accepts |
|---|---|---|---|---|
| Uniform Lateral (Wind) Load (N/m) | `udl` | 300 | 300 | range 20–5000 |
| Stud Height (Span) | `span` | 3 m | 10 ft | mm, cm, m, in, ft, yd; range 0.01–8 m |
| Modulus of Elasticity E | `elasticModulus` | 200000 MPa | 29007500 psi | pa, kpa, mpa, psi, psf, in_wc; range 190000000000–210000000000 Pa |
| Effective Moment of Inertia I_eff (×10⁶ mm⁴) | `effectiveMomentOfInertia` | 2 | 2 | range 0.005–50 |
| Deflection Limit | `deflectionLimitRatio` | L/240 | L/240 | `240`, `360`, `600` |

- **Uniform Lateral (Wind) Load (N/m)**: The uniformly distributed lateral (wind) load along the stud's height.
- **Stud Height (Span)**: The stud's clear span between top and bottom track (or bracing).
- **Modulus of Elasticity E**: The steel's modulus of elasticity — 200,000 MPa (29,000,000 psi) is standard for structural steel.
- **Effective Moment of Inertia I_eff (×10⁶ mm⁴)**: The stud's AISI S100 effective moment of inertia, from the manufacturer's span table for its size and gauge.
- **Deflection Limit**: The applicable code deflection limit, as a fraction of the span.

## The answer on the opening values

Worked exactly as the page works it, on the values each system opens on.

### Metric

| Result | Value |
|---|---|
| **Calculated stud deflection** | 0.791 mm |
| Allowable limit | 12.5 mm |

### US customary

| Result | Value |
|---|---|
| **Calculated stud deflection** | 0.0332 in |
| Allowable limit | 0.5 in |

- Confidence: medium.
- The figure is compared against a limit; that is a check of the number, not an approval.

## How it is worked out

The deflection this stud works out to is below the L/240 limit for the span entered shown with it — you entered it from the deflection ratio you chose. I_eff has to be the manufacturer's or AISI S100 figure for this exact stud size and gauge; an assumed one moves this answer in proportion. Being under one limit is not a design. Nothing else is checked here — not the other limit states, not the connections, not the member the load arrives from.

The working the page shows, in order: Allowable limit; then calculated stud deflection.

The method, derived in full:

- [Deflection, Creep and Vibration: What Governs a Span](https://craftquantities.com/methodology/deflection-and-vibration/): Why doubling a span multiplies its deflection by sixteen, why a stronger grade of steel does nothing for it, and why a floor that passes every deflection check can still be unacceptable to walk on.

What this calculation does not cover:

- The load field takes a line load already resolved onto one stud, not a wind pressure. Working that out is the reader's own step: the design pressure multiplied by the width of wall that stud picks up, which is the stud spacing for a typical stud but roughly half the opening width plus half a spacing for a jamb stud beside a door or window. Type a pressure straight into the field and the answer is wrong by exactly that tributary width.
- The formula is the simply supported single span, pinned at both tracks, with the whole stud height taken as the span. Deflection goes as the fourth power of that span, so a height 10 per cent out shifts the answer by about 46 per cent, and a stud braced at mid-height by a bridging row is a different case: the span to enter is the distance between braces, not the storey height.
- This is a serviceability check and nothing else. Bending capacity, web crippling where the stud bears on the track, and the combined axial-plus-bending case for a load-bearing stud are separate AISI S100 checks that a passing deflection result says nothing about. The elastic formula also assumes the flanges are held against twisting by sheathing or bridging, because a C-section's shear centre lies outside the web; an unrestrained stud rotates as it bends and moves more than this arithmetic reports.
- The three limit ratios are a menu, and the page does not know which one your specification or finish manufacturer requires. It also leaves the load exactly as typed: many codes check deflection under a serviceability wind that is a fraction of the ultimate design wind, and that fraction is jurisdictional, so putting an ultimate-level line load against an L/360 limit compares two different load cases.
- The result is the stud's own mid-height bending and nothing more. It excludes the movement at the head of wall that a deflection track exists to absorb, the deflection of the floor or roof structure above, and any slip in an undersized nested track leg. The finish sees the sum of all of those, which is what a tight L/600 brittle-finish limit is really trying to protect.

A professional must decide:

- Structure: sizes, thicknesses, spans, reinforcement and bearing are a structural engineer's or the building official's decision. This is a quantity, not a design.

## Sources

As the calculator cites them (sources checked 2026-09-05):

- AISI S100 governs how a CFS stud's effective section properties (I_eff) are derived, but the deflection check itself is standard elastic beam theory: Δ = 5wL⁴/(384EI_eff); manufacturers (SSMA, ClarkDietrich) publish I_eff per stud size/gauge in their span tables for use in this formula

A code or standard has force only where a jurisdiction has adopted it, usually with local amendments; check what is in force with the authority where you build.

## Questions answered on the page

**Where does the effective moment of inertia (I_eff) come from?**

From the stud makers' span tables: manufacturers like SSMA or ClarkDietrich publish it per stud size and gauge, derived from the effective (post-local-buckling) section properties AISI S100 requires. I_eff is not a simple geometric property you can compute from the stud's nominal dimensions.

**The table gives I in in⁴ — how do I enter it here?**

Multiply by 0.4162 to get the ×10⁶ mm⁴ this field wants: 0.191 in⁴ becomes 0.0795, and 1.83 in⁴ becomes 0.762. It matters which way round you get it, because deflection goes as 1/I — entering a number 2.4 times too large reports a movement 2.4 times too small, and this page ends in a pass or a fail. If the figure you type is a whole order of magnitude away from the 0.02 to 1.0 that C-studs occupy, the unit is the first thing to check.

**Why do brittle finishes need a tighter deflection limit (L/600)?**

Rigid or brittle wall finishes (tile, stucco, some gypsum assemblies) crack under smaller amounts of stud movement than more flexible finishes, so codes and manufacturers commonly specify a tighter L/600 limit for studs behind those finishes versus the more common L/240 or L/360.

**Does passing this deflection check confirm the stud is structurally adequate overall?**

No — this checks lateral (wind) deflection serviceability only. The stud's bending and axial capacity (including any gravity load it also carries) must be checked separately per AISI S100 to confirm overall structural adequacy.

## Related calculators

- [Cold-Formed Steel Stud Spacing & Count Calculator](https://craftquantities.com/calculators/materials-quantities/cfs-stud-spacing-calculator/)
- [Glulam Beam Deflection Checker](https://craftquantities.com/calculators/materials-quantities/glulam-beam-deflection-calculator/)

## Run it from a program

- REST: `GET https://api.craftquantities.com/v1/calculate/cfs-stud-deflection-calculator` with each input as a query parameter, a length, area or volume with its unit; `https://api.craftquantities.com/v1/describe/cfs-stud-deflection-calculator` lists the inputs.
- MCP: the `calculate` tool at https://api.craftquantities.com/mcp with `slug` `cfs-stud-deflection-calculator`.
- Definition and test vectors: https://craftquantities.com/api/v1/calculators/cfs-stud-deflection-calculator.json

---
Source: https://craftquantities.com/calculators/materials-quantities/cfs-stud-deflection-calculator/
Craft Quantities: free to read, cite and link to; the pages are not licensed for republication. Quantities only: no prices, no design and no certification.