# Cavity Wall Weep Hole Spacing Calculator

> Estimate the number of weep holes needed along the base of a brick veneer or cavity wall.

Page: https://craftquantities.com/calculators/materials-quantities/cavity-wall-weep-hole-calculator/ (calculator). This is the page's Markdown copy; the HTML page is the canonical version.

Version 1.0.1, sources checked 2026-09-06, 2 published test vectors.

Weep holes needed: 18 weep holes for Wall Length 33 ft and Weep Hole Spacing 24 in, the page's opening figures; on the metric page, 10 m and 609.6 mm give 18 weep holes. Sources are cited below.

## Inputs

A length, area or volume is entered with its unit. The page opens on the values below: a metric reader sees the metric column, a US customary reader the other.

| Input | id | Opens at (metric) | Opens at (US customary) | Accepts |
|---|---|---|---|---|
| Wall Length | `wallLength` | 10 m | 33 ft | mm, cm, m, in, ft, yd; range 0.01–200 m |
| Weep Hole Spacing (on-center) | `weepHoleSpacing` | 609.6 mm | 24 in | mm, cm, m, in, ft, yd; range 0.4064–0.8382 m |

- **Wall Length**: The total length of cavity/veneer wall base needing weep holes.
- **Weep Hole Spacing (on-center)**: The on-center spacing between weep holes.

## The answer on the opening values

Worked exactly as the page works it, on the values each system opens on.

### Metric

| Result | Value |
|---|---|
| **Weep holes needed** | 18 weep holes |

### US customary

| Result | Value |
|---|---|
| **Weep holes needed** | 18 weep holes |

- Confidence: medium.

## How it is worked out

The plus-one term already places a weep at each end of this run, so do not add two more by hand — and where elevations meet, counting each run separately books the shared corner position twice. What is NOT counted: weeps above every door and window head, at shelf angles, and at any other flashing discontinuity, each of which needs its own row at this spacing.

The method, derived in full:

- [Ventilation: Net Free Area, Air Change and the Openings That Deliver Them](https://craftquantities.com/methodology/ventilation-openings-and-air-change/): Why a wooden louvre delivers a quarter of the hole you cut and a metal one three-quarters, why intake and exhaust have to be balanced or the roof ventilates the house, and why doubling the pressure does not double the flow.

What this calculation does not cover:

- One straight run along one flashing line, and nothing above it. Every cavity tray higher up the wall — over each lintel, at each cill, under each shelf angle, at every roof abutment — is a separate drainage compartment needing its own weeps in the course directly above its own flashing, and none of those openings are in this figure.
- Nothing here checks the spacing you typed against the code you build under. The field accepts 406 to 838 mm (16 to 33 in), which is the North American band; British practice is tighter, commonly around 450 mm centres, and other markets differ again. This is arithmetic on the figure you enter, not a verdict that the figure is permitted.
- The weep itself is outside the model — opening size, free area, and whether the type you have matches the spacing you chose. Wick and tube weeps move far less water than an open perpend, and cellular inserts and insect screening cut free area below the raw size of the hole, so the same count of openings is not the same drainage capacity.
- Position decides whether any of them work and position is not counted. Weeps belong in the perpends of the course immediately above the flashing, formed as the bricks go back; one course too high and water sits permanently below its own outlet, and an opening with a mortar dam behind it drains nothing while still counting here.
- Vents are not in this number. Openings at the head of a drainage compartment — under soffits, under shelf angles, immediately below each cavity tray — are what let the cavity dry rather than merely drain, and they are a second set of openings on top of the ones counted here.

## Sources

As the calculator cites them (sources checked 2026-09-06):

- Standard cavity/veneer wall practice places weep holes at regular spacing along the wall base directly above flashing, typically every 16-33 in on-center depending on the weep hole type, which is the 406 to 838 mm this page accepts

A code or standard has force only where a jurisdiction has adopted it, usually with local amendments; check what is in force with the authority where you build.

## Questions answered on the page

**What decides the spacing — the wall, or the water?**

The water, and specifically how far it will run sideways before it finds a way out. A weep hole is an exit, not a vent: water that has crossed the cavity lands on a tray or a DPC and travels along it under gravity and surface tension until it meets an opening. Space them too far apart and the tray holds a standing head of water that eventually finds the inner leaf, which is the failure people blame on the tray rather than on the holes. That is also why every tray needs its own weeps — one above a lintel, one at the base, one at each cill — rather than a single set at the bottom of the wall, and why a weep sitting even one course too high leaves water permanently below its own outlet.

**Why do cavity walls need weep holes?**

Water that gets past the brick veneer collects on the flashing at the base of the cavity — weep holes let that water drain out instead of accumulating and potentially causing efflorescence, freeze-thaw damage, or interior moisture problems.

**What types of weep holes are common?**

Open head joints (simplest, just an unfilled vertical mortar joint), plastic or mesh weep vents (better pest resistance), and wick/rope weeps (draw water out by capillary action) — spacing requirements vary somewhat by type.

**Do weep holes need to align with the cavity drainage mat?**

Ideally yes — weep holes should be positioned so they connect directly to the drainage path created by any cavity drainage mat or mesh, not blocked by mortar droppings or other debris.

## Related calculators

- [Brick Calculator](https://craftquantities.com/calculators/materials-quantities/brick-calculator/)
- [Cavity Wall Drainage Mat Area Calculator](https://craftquantities.com/calculators/materials-quantities/cavity-drainage-mat-calculator/)

## Run it from a program

- REST: `GET https://api.craftquantities.com/v1/calculate/cavity-wall-weep-hole-calculator` with each input as a query parameter, a length, area or volume with its unit; `https://api.craftquantities.com/v1/describe/cavity-wall-weep-hole-calculator` lists the inputs.
- MCP: the `calculate` tool at https://api.craftquantities.com/mcp with `slug` `cavity-wall-weep-hole-calculator`.
- Definition and test vectors: https://craftquantities.com/api/v1/calculators/cavity-wall-weep-hole-calculator.json

---
Source: https://craftquantities.com/calculators/materials-quantities/cavity-wall-weep-hole-calculator/
Craft Quantities: free to read, cite and link to; the pages are not licensed for republication. Quantities only: no prices, no design and no certification.