# Blown-In Insulation Bag Count Calculator

> Calculate how many bags of blown-in insulation are needed for an attic or wall cavity at a target depth.

Page: https://craftquantities.com/calculators/materials-quantities/blown-insulation-bag-calculator/ (calculator). This is the page's Markdown copy; the HTML page is the canonical version.

Version 1.0.1, sources checked 2026-09-06, 2 published test vectors.

Bags needed: 12 bags for Area to Insulate 1080 sq ft and Target Installed Depth 11.75 in, the page's opening figures; on the metric page, 100 m² and 30 cm give 12 bags. Sources are cited below.

## Inputs

A length, area or volume is entered with its unit. The page opens on the values below: a metric reader sees the metric column, a US customary reader the other.

| Input | id | Opens at (metric) | Opens at (US customary) | Accepts |
|---|---|---|---|---|
| Area to Insulate | `area` | 100 m² | 1080 sq ft | m2, ft2, mm2, in2; range 0.01–1000 m² |
| Target Installed Depth | `depth` | 30 cm | 11.75 in | mm, cm, m, in, ft, yd; range 0.01–1 m |
| Bag Coverage Yield at This Depth (m³ per bag) | `bagYield` | 2.6 | 2.6 | range 0.2–5 |

- **Area to Insulate**: The attic or cavity area to be covered with blown-in insulation.
- **Target Installed Depth**: The target settled/installed depth of loose-fill insulation.
- **Bag Coverage Yield at This Depth (m³ per bag)**: The volume of coverage one bag provides at the target installed depth, per the manufacturer's chart.

## The answer on the opening values

Worked exactly as the page works it, on the values each system opens on.

### Metric

| Result | Value |
|---|---|
| **Bags needed** | 12 bags |
| Total insulation volume | 30 m³ |

### US customary

| Result | Value |
|---|---|
| **Bags needed** | 12 bags |
| Total insulation volume | 39.17 yd³ |

- Confidence: medium.

## How it is worked out

Bag yield depends on the target installed density, which varies by depth and product per the manufacturer's coverage chart — always use the yield figure printed on the bag for your specific target depth/R-value, not a generic assumption.

The working the page shows, in order: Total insulation volume; then bags needed.

The method, derived in full:

- [Quantity, Waste and Rounding](https://craftquantities.com/methodology/quantity-waste-and-rounding/): Why a material count is a ceiling function rather than a division, and why the waste factor — not the geometry — carries the risk.

What this calculation does not cover:

- Depth on a ruler is not R-value, and the bag count is what proves it. A coverage chart ties each R-value to a minimum number of bags per unit of area as well as to a depth, so a yield taken from a lower-density line gives fewer bags at the same finished depth — the attic measures right, performs below its rating, and nothing on site catches it afterwards.
- Attic yields do not transfer to closed cavities. Dense-packing a wall or a cathedral cavity is done at a far higher density to stop the material settling and leaving a void at the top, which cuts the coverage a bag gives by half or more, and the fill goes in through a tube around fire blocking, wiring and bracing rather than being blown across an open floor.

## Sources

As the calculator cites them (sources checked 2026-09-06):

- Bags needed = ceil(required volume ÷ the bag's rated coverage yield at the installed density), the standard method for estimating blown-in (loose-fill) insulation material from the manufacturer's bag coverage chart

A code or standard has force only where a jurisdiction has adopted it, usually with local amendments; check what is in force with the authority where you build.

## Questions answered on the page

**Why does bag coverage yield change with depth?**

Because a bag contains a fixed mass of material, and installing it at a greater depth spreads that mass over less floor area. The coverage yield per bag drops as the target depth increases, which is why manufacturers publish coverage charts: a greater depth (higher density, for higher R-value per inch) compresses the same mass into less floor area.

**Should I round up the number of bags?**

Yes — bags are a whole-unit product, so the required volume is divided by the per-bag yield and rounded up to ensure full coverage at the target depth across the whole area.

**Does settling reduce the depth over time?**

Yes, somewhat, which is why manufacturers' coverage charts already build in an initial installed depth that allows for expected settling and still reaches the rated long-term R-value. Always install to the chart's stated initial depth, not just the nominal settled depth.

## Related calculators

- [Attic Insulation Upgrade Calculator](https://craftquantities.com/calculators/insulation-efficiency/attic-insulation-upgrade-calculator/)
- [Insulation Batt Calculator](https://craftquantities.com/calculators/insulation-efficiency/insulation-batt-calculator/)
- [Cavity Wall & Stud Bay Insulation Fill Calculator](https://craftquantities.com/calculators/materials-quantities/cavity-fill-volume-calculator/)

## Run it from a program

- REST: `GET https://api.craftquantities.com/v1/calculate/blown-insulation-bag-calculator` with each input as a query parameter, a length, area or volume with its unit; `https://api.craftquantities.com/v1/describe/blown-insulation-bag-calculator` lists the inputs.
- MCP: the `calculate` tool at https://api.craftquantities.com/mcp with `slug` `blown-insulation-bag-calculator`.
- Definition and test vectors: https://craftquantities.com/api/v1/calculators/blown-insulation-bag-calculator.json

---
Source: https://craftquantities.com/calculators/materials-quantities/blown-insulation-bag-calculator/
Craft Quantities: free to read, cite and link to; the pages are not licensed for republication. Quantities only: no prices, no design and no certification.