# Rafter Bird's Mouth Cut Calculator

> Calculate the seat cut and heel cut dimensions for a rafter's bird's mouth notch at the wall plate.

Page: https://craftquantities.com/calculators/materials-quantities/birds-mouth-cut-calculator/ (calculator). This is the page's Markdown copy; the HTML page is the canonical version.

Version 1.0.1, sources checked 2026-09-02, 2 published test vectors.

Heel cut height: 1.75 in for Wall Plate Width 3.5 in, the page's opening figures; on the metric page, 88.9 mm gives 44.5 mm. Sources are cited below.

## Inputs

A length, area or volume is entered with its unit. The page opens on the values below: a metric reader sees the metric column, a US customary reader the other.

| Input | id | Opens at (metric) | Opens at (US customary) | Accepts |
|---|---|---|---|---|
| Wall Plate Width | `wallPlateWidth` | 88.9 mm | 3.5 in | mm, cm, m, in, ft, yd; range 0.01–0.1524 m |
| Roof Pitch (rise per 12) | `roofPitch` | 6 | 6 | range 1–24 |

- **Wall Plate Width**: The width of the top plate the rafter's bird's mouth notch will seat on.
- **Roof Pitch (rise per 12)**: The roof's slope, expressed as inches of rise per 12 inches of horizontal run.

## The answer on the opening values

Worked exactly as the page works it, on the values each system opens on.

### Metric

| Result | Value |
|---|---|
| **Heel cut height** | 44.5 mm |
| Seat cut length (= plate width) | 88.9 mm |

### US customary

| Result | Value |
|---|---|
| **Heel cut height** | 1.75 in |
| Seat cut length (= plate width) | 3.5 in |

## How it is worked out

The working the page shows, in order: Seat cut length (= plate width); then heel cut height.

The method, derived in full:

- [Slope, Pitch and True Surface Area](https://craftquantities.com/methodology/slope-pitch-and-true-area/): Converting a plan footprint into the sloped area a roof actually has — the factor that decides whether a shingle order is right or a third short.

What this calculation does not cover:

- The seat cut length shown is the plate width measured horizontally, which is not the distance to mark along the sloping edge of the rafter. On a 3.5 in plate at 6/12 the notch spans 3.91 in along the rafter's underside, that being the plate width divided by the cosine of the pitch angle, and the page gives neither that layout dimension nor the position of the notch along the rafter.
- Nothing here tests the section of rafter left above the notch, and no rafter depth is asked for. The 1.75 in heel cut on a 3.5 in plate at 6/12 removes 1.57 in measured square to the rafter's edges rather than 1.75 in, so reading the heel cut height straight against a fraction of the rafter depth overstates the notch.
- Roof pitch is taken strictly as rise per 12 units of run and is never converted, even when the plate width is entered in millimetres. Entering 20 for a 20 degree roof returns 5.83 in instead of 1.27 in, over four times the correct heel cut, because 20 in 12 is a 59 degree slope and that value sits inside the accepted 1 to 24 range.
- The geometry is that of a common rafter meeting the plate square. A hip or valley rafter travels 16.97 in in plan for every 12 in of common run, so at 6/12 its heel cut is about 1.24 in rather than 1.75 in, its seat crosses the plate at the corner instead of sitting square across it, and dropping or backing the hip to line up with the jacks alters the seat cut again.
- A circular saw taken to the intersection of the two cuts overruns the inner corner on the far face of the rafter, so the notch as cut is deeper than these two dimensions describe unless the corner is finished with a handsaw. Saw kerf, a crowned or twisted top plate, and sheathing carried up past the plate are all outside the figures, as are the ridge plumb cut, the half ridge thickness deduction and the tail cut.
- Engineered rafters are a separate matter entirely. I-joists and structural composite lumber permit no bird's mouth beyond a manufacturer-detailed seat at the low bearing, with an I-joist flange never notched, so applying this plate width times tangent result to them is not a small error but a prohibited cut.

A professional must decide:

- Engineered rafters are a separate matter entirely. I-joists and structural composite lumber permit no bird's mouth beyond a manufacturer-detailed seat at the low bearing, with an I-joist flange never notched, so applying this plate width times tangent result to them is not a small error but a prohibited cut.

## Sources

As the calculator cites them (sources checked 2026-09-02):

- Standard carpentry bird's mouth layout: seat cut length equals the wall plate width; heel cut height = wall plate width × tan(roof pitch angle)

A code or standard has force only where a jurisdiction has adopted it, usually with local amendments; check what is in force with the authority where you build.

## Questions answered on the page

**What are the seat cut and heel cut on a bird's mouth?**

The seat cut is the horizontal cut that rests flat on top of the wall plate, and its length equals the plate width. The heel cut is the vertical cut at the outer edge of the notch, and its height grows with a steeper roof pitch since the rafter's underside angles away from the plate more sharply.

**Why does a steeper pitch produce a taller heel cut?**

The heel cut height is the plate width times the tangent of the roof's slope angle — as the pitch (and therefore the angle) increases, tan(angle) grows faster than linearly, so the heel cut height rises quickly at steep pitches.

**Does this account for the rafter's overall depth or the remaining structural depth after the notch?**

No — this calculates the notch geometry only. Checking that enough rafter depth remains above the bird's mouth to carry the design loads (see NDS notch provisions) is a separate structural check.

## Related calculators

- [Common Gable Rafter Length Calculator](https://craftquantities.com/calculators/materials-quantities/common-rafter-length-calculator/)
- [Roof Truss Raised-Heel Height Calculator](https://craftquantities.com/calculators/materials-quantities/truss-heel-height-calculator/)

## Run it from a program

- REST: `GET https://api.craftquantities.com/v1/calculate/birds-mouth-cut-calculator` with each input as a query parameter, a length, area or volume with its unit; `https://api.craftquantities.com/v1/describe/birds-mouth-cut-calculator` lists the inputs.
- MCP: the `calculate` tool at https://api.craftquantities.com/mcp with `slug` `birds-mouth-cut-calculator`.