Version 1.0.0, sources checked 2026-11-14, 5 published test vectors.

Risers: 18 risers for Total Rise 10 ft, Riser You Are Aiming For 7 in and Going 11 in, the page's opening figures; on the metric page, 3 m, 180 mm and 280 mm give 17 risers. Sources are cited below.

## Inputs

A length, area or volume is entered with its unit. The page opens on the values below: a metric reader sees the metric column, a US customary reader the other.

| Input | id | Opens at (metric) | Opens at (US customary) | Accepts |
|---|---|---|---|---|
| Total Rise (floor to floor) | `totalRise` | 3 m | 10 ft | mm, cm, m, in, ft, yd; range 0.3–8 m |
| Riser You Are Aiming For | `targetRiser` | 180 mm | 7 in | mm, cm, m, in, ft, yd; range 0.1–0.3 m |
| Going (nosing to nosing) | `going` | 280 mm | 11 in | mm, cm, m, in, ft, yd; range 0.2–0.4 m |
| Risers in the first flight | `firstFlight` | 9 | 9 | range 2–30 |
| First flight width | `firstWidth` | 1.5 m | 5 ft | mm, cm, m, in, ft, yd; range 0.8–4 m |
| Return flight width | `returnWidth` | 1 m | 3.5 ft | mm, cm, m, in, ft, yd; range 0.6–3 m |
| Gap beside the first flight | `gap` | 100 mm | 4 in | mm, cm, m, in, ft, yd; range 0–1 m |
| Landing depth | `landingDepth` | 1.5 m | 5 ft | mm, cm, m, in, ft, yd; range 0.6–4 m |
| Nosing | `nosing` | 25 mm | 1 in | mm, cm, m, in, ft, yd; range 0–0.05 m |
| Tread thickness | `treadThickness` | 32 mm | 1.25 in | mm, cm, m, in, ft, yd; range 0.015–0.06 m |
| Stringer board depth | `stringerDepth` | 286 mm | 11.25 in | mm, cm, m, in, ft, yd; range 0.2–0.4 m |
| Stringers under the first flight | `stringersFirst` | 3 | 3 | range 2–8 |
| Stringers under each return flight | `stringersReturn` | 2 | 2 | range 2–6 |
| Floor depth at the opening | `floorDepth` | 300 mm | 11.75 in | mm, cm, m, in, ft, yd; range 0–0.6 m |
| Headroom to keep | `headroom` | 2.032 m | 80 in | mm, cm, m, in, ft, yd; range 1.8–2.5 m |
| Tread board length | `boardStock` | 3.6 m | 12 ft | mm, cm, m, in, ft, yd; range 0.6–6 m |
| Allowance (%) | `wastePercent` | 10 | 10 | range 0–30 |
| Code for the readout | `buildingCode` | US — IRC | US — IRC | `irc`, `uk`, `au`, `ca`, `generic` |

- **Total Rise (floor to floor)**: Finished floor below to finished floor above.
- **Riser You Are Aiming For**: The rise per step you want.
- **Going (nosing to nosing)**: The same on every flight.
- **Risers in the first flight**: Up to the half landing.
- **First flight width**: The wide flight up the middle.
- **Return flight width**: Each of the two flights back up.
- **Gap beside the first flight**: Between the first flight and each return.
- **Landing depth**: In the direction of travel.
- **Nosing**: Tread past its riser.
- **Tread thickness**: On each notch.
- **Stringer board depth**: Your board, never recommended.
- **Stringers under the first flight**: Your count.
- **Stringers under each return flight**: Your count.
- **Floor depth at the opening**: Upper floor to the ceiling below.
- **Headroom to keep**: Clear height over the flights.
- **Tread board length**: Each board gives as many treads as fit whole.
- **Allowance (%)**: On treads, risers and rail.
- **Code for the readout**: The code the risers, going, landing and headroom are read against.

## The answer on the opening values

Worked exactly as the page works it, on the values each system opens on.

### Metric

| Result | Value |
|---|---|
| **Risers** | 17 risers |
| Riser height | 176.47 mm |
| Risers in each return flight | 8 risers |
| Landing height | 1.59 m |
| Stair width on plan | 3.7 m |
| Stair depth on plan | 3.74 m |
| First flight's stringer board | 2.63 m |
| Return flights' stringer board | 2.3 m |
| Treads in all | 22 treads |
| Handrail, total with the allowance | 16.67 m |
| Open over each return flight | 1.96 m |

### US customary

| Result | Value |
|---|---|
| **Risers** | 18 risers |
| Riser height | 6.67 in |
| Risers in each return flight | 9 risers |
| Landing height | 5 ft |
| Stair width on plan | 12.67 ft |
| Stair depth on plan | 12.33 ft |
| First flight's stringer board | 8.52 ft |
| Return flights' stringer board | 8.52 ft |
| Treads in all | 24 treads |
| Handrail, total with the allowance | 58.58 ft |
| Open over each return flight | 7.33 ft |

## How it is worked out

WITHIN THE LIMITS CHECKED — US IRC 2024: riser height 6.95 in (176 mm) and tread depth 11.02 in (280 mm) are inside the limits this calculator checks. That is not a compliance determination: headroom, handrails, guards, nosings and width are not checked, and the building control body or inspector decides. On this page, headroom is read on its own: the opening is worked out for 2032 mm (80.0 in) of headroom over the pitch line, at or above the 6 ft 8 in (2032 mm) of IRC 2024 R311.7.2; the headroom as built is measured on site. The landing is 1500 mm (59.1 in) deep, at or over the stair's width and at least 36 in (914 mm) (IRC R311.7.6).

The working the page shows, in order: Riser height; Risers in each return flight; Landing height; Stair width on plan; Stair depth on plan; First flight's stringer board; Return flights' stringer board; Treads in all; Handrail, total with the allowance; Open over each return flight; then risers.

The method, derived in full:

- [Stair Geometry, Ramps and Guarding](https://craftquantities.com/methodology/stair-geometry-and-guarding/): Why you choose the number of risers rather than their height, why the spread across a whole flight is held to three-eighths of an inch, and why a cable railing has to be checked deflected rather than at rest.

What this calculation does not cover:

- This lays a split stair out; it does not approve it. The riser, going, landing and headroom are read against your code; the widths a split stair's flights must keep for the people it serves (its occupancy) are your building official's call.
- The stringers' depth and count, the landing's framing and its posts are your engineer's or the stair maker's: entered or left out, never sized here.
- The return flights are drawn the same width and straight; a split stair whose returns curve, or whose first flight widens at its foot, is set out by the maker.

A professional must decide:

- This lays a split stair out; it does not approve it. The riser, going, landing and headroom are read against your code; the widths a split stair's flights must keep for the people it serves (its occupancy) are your building official's call.
- The stringers' depth and count, the landing's framing and its posts are your engineer's or the stair maker's: entered or left out, never sized here.
- Structure: sizes, thicknesses, spans, reinforcement and bearing are a structural engineer's or the building official's decision. This is a quantity, not a design.

## Sources

As the calculator cites them (sources checked 2026-11-14):

- Risers shared equally over the total rise (this site's stair rise and run rule, rounded up); each flight's stringer from this site's full-size stringer template
- US: IRC R311.7.5 and R311.7.6 (risers, treads, landings at least the stair's width and 36 in deep); UK: Approved Document K section 1 (landings at least the width of the flight); Australia: NCC Housing Provisions 11.2.5(1)(a) (landings at least 750 mm); Canada: NBC 9.8.6.3.(1)
- The opening over each return flight = nosing + (headroom + floor depth) x going / riser, as this site's stair stringer page works it

The site's pages for the documents these name:

- [International Residential Code](https://craftquantities.com/standards/icc/irc/)
- [Approved Documents to the Building Regulations (England)](https://craftquantities.com/standards/uk-gov/uk-approved-documents/)

A code or standard has force only where a jurisdiction has adopted it, usually with local amendments; check what is in force with the authority where you build.

## Questions answered on the page

**What is a bifurcated stair?**

A split or imperial stair: one wide flight rises to a half landing and two narrower flights turn back up on either side of it to the floor above.

**How are the risers split?**

All risers are the same height. The first flight takes the count you enter and the two return flights share the rest equally: 17 risers of 176 mm split 9 up the middle and 8 up each side.

**How big is the landing?**

As wide as the whole stair, the first flight plus both gaps and both returns, and as deep as you enter; each code's landing rule is read against that depth.

## Related calculators

- [L-Shaped and U-Shaped Stair Calculator (Landings, Winders, Stringers, Treads and Risers)](https://craftquantities.com/calculators/materials-quantities/landing-stair-calculator/)
- [Stair Rise & Run Calculator](https://craftquantities.com/calculators/renovation-construction/stair-calculator/)
- [Stair Stringer Calculator (Cuts, Floor Opening, Treads and Risers)](https://craftquantities.com/calculators/materials-quantities/stair-stringer-calculator/)
- [Handrail Gooseneck and Easing Calculator (Rail Heights, Gooseneck Rise and Mitre Cuts)](https://craftquantities.com/calculators/materials-quantities/handrail-gooseneck-calculator/)

## Run it from a program

- REST: `GET https://api.craftquantities.com/v1/calculate/bifurcated-stair-calculator` with each input as a query parameter, a length, area or volume with its unit; `https://api.craftquantities.com/v1/describe/bifurcated-stair-calculator` lists the inputs.
- MCP: the `calculate` tool at https://api.craftquantities.com/mcp with `slug` `bifurcated-stair-calculator`.
- Definition and test vectors: https://craftquantities.com/api/v1/calculators/bifurcated-stair-calculator.json

---
Source: https://craftquantities.com/calculators/materials-quantities/bifurcated-stair-calculator/
Craft Quantities: free to read, cite and link to; the pages are not licensed for republication. Quantities only: no prices, no design and no certification.