# Bentonite Waterproofing Swell Thickness Calculator

> Calculate the hydrated (swollen) gel thickness a bentonite waterproofing panel forms when it absorbs water.

Page: https://craftquantities.com/calculators/materials-quantities/bentonite-swell-calculator/ (calculator). This is the page's Markdown copy; the HTML page is the canonical version.

Version 1.1.1, sources checked 2026-09-06, 2 published test vectors.

Hydrated (swollen) gel thickness: 2.46 in for Bentonite Content 1.02 lb/sq ft and Bentonite Dry Density 49.94 pcf, the page's opening figures; on the metric page, 5 kg/m² and 800 kg/m³ give 62.5 mm. Sources are cited below.

## Inputs

A length, area or volume is entered with its unit. The page opens on the values below: a metric reader sees the metric column, a US customary reader the other.

| Input | id | Opens at (metric) | Opens at (US customary) | Accepts |
|---|---|---|---|---|
| Bentonite Content | `bentoniteContent` | 5 kg/m² | 1.02408 lb/sq ft | kgm2, lbft2; range 2–10 kg/m² |
| Bentonite Dry Density | `dryDensity` | 800 kg/m³ | 49.9424 pcf | kgm3, pcf, lbyd3; range 600–1000 kg/m³ |
| Volumetric Swell Factor | `swellFactor` | 10 | 10 | range 8–15 |

- **Bentonite Content**: The mass of bentonite clay per unit area of the waterproofing panel.
- **Bentonite Dry Density**: The unhydrated (dry) bulk density of the bentonite clay.
- **Volumetric Swell Factor**: How many times larger the bentonite's volume becomes once fully hydrated.

## The answer on the opening values

Worked exactly as the page works it, on the values each system opens on.

### Metric

| Result | Value |
|---|---|
| **Hydrated (swollen) gel thickness** | 62.5 mm |
| Dry (unhydrated) thickness | 6.25 mm |

### US customary

| Result | Value |
|---|---|
| **Hydrated (swollen) gel thickness** | 2.46 in |
| Dry (unhydrated) thickness | 0.25 in |

- Confidence: medium.

## How it is worked out

Swell factor varies by bentonite grade and confinement condition — this is a general reference figure. Bentonite panels require adequate confining pressure (backfill or structural confinement) to develop their full sealing performance; unconfined swell can behave differently.

The working the page shows, in order: Dry (unhydrated) thickness; then hydrated (swollen) gel thickness.

The method, derived in full:

- [Soil State: Void Ratio, Compaction and Consolidation](https://craftquantities.com/methodology/soil-state-and-consolidation/): Why 95% compaction is not a number until you name the test, why what a site was loaded with in the past matters more than what you are about to put on it, and why seepage roughly halves a slope's factor of safety.

What this calculation does not cover:

- The swell factor on a data sheet is measured in clean water. Sodium bentonite gives up much of that swell where the groundwater is saline, hard or rich in calcium, because calcium displaces sodium in the clay and the hydrated volume collapses toward a fraction of the laboratory figure — on brackish or contaminated ground the panel has to be a contaminant-resistant grade, and the number above stops describing it.
- A gel thickness is not a seal. Bentonite waterproofing leaks at panel laps, at pipe penetrations, at the footing-to-wall joint and at the top termination, not through the middle of a panel, and every one of those needs its own lap width, granular bentonite or detail strip — none of which follows from the thickness computed here.

## Sources

As the calculator cites them (sources checked 2026-09-06):

- Dry bentonite layer thickness = bentonite content per area ÷ dry density; hydrated bentonite clay swells dramatically when wetted (commonly cited swell factors of roughly 10-15x by volume) to form a self-healing, low-permeability gel that seals small punctures and cracks

A code or standard has force only where a jurisdiction has adopted it, usually with local amendments; check what is in force with the authority where you build.

## Questions answered on the page

**Why does bentonite need to swell so much to be effective?**

The dramatic volume increase when bentonite clay hydrates — commonly 10-15x by volume — is what lets it close small punctures, seams, and cracks in the waterproofing layer, forming a continuous, low-permeability gel where the dry panel alone would leave gaps.

**Does the swell factor stay the same for every project?**

No — it varies by bentonite grade and by confinement condition. This calculator uses whatever swell factor you enter as a general reference figure, so check the manufacturer's data for your specific product grade.

**Does bentonite swell fully without backfill in place?**

Not to its full sealing performance: bentonite panels need adequate confining pressure, typically from backfill or structural confinement, to develop it. Unconfined swell can behave differently than the confined swell factor assumed here.

## Related calculators

- [Cold-Applied Liquid Waterproofing Membrane Volume Calculator](https://craftquantities.com/calculators/materials-quantities/liquid-waterproofing-volume-calculator/)
- [Below-Grade Waterproofing Membrane Roll Calculator](https://craftquantities.com/calculators/materials-quantities/waterproofing-membrane-roll-calculator/)

## Run it from a program

- REST: `GET https://api.craftquantities.com/v1/calculate/bentonite-swell-calculator` with each input as a query parameter, a length, area or volume with its unit; `https://api.craftquantities.com/v1/describe/bentonite-swell-calculator` lists the inputs.
- MCP: the `calculate` tool at https://api.craftquantities.com/mcp with `slug` `bentonite-swell-calculator`.
- Definition and test vectors: https://craftquantities.com/api/v1/calculators/bentonite-swell-calculator.json

---
Source: https://craftquantities.com/calculators/materials-quantities/bentonite-swell-calculator/
Craft Quantities: free to read, cite and link to; the pages are not licensed for republication. Quantities only: no prices, no design and no certification.