# Basement Wall At-Rest Earth Pressure Calculator (with Groundwater)

> At-rest earth pressure on a propped basement wall, with surcharge and groundwater carried separately: base pressure, thrust per run and where it acts.

Page: https://craftquantities.com/calculators/materials-quantities/basement-wall-at-rest-pressure-calculator/ (calculator). This is the page's Markdown copy; the HTML page is the canonical version.

Version 1.0.0, sources checked 2026-09-22, 4 published test vectors.

Total thrust on the wall per unit run: 3,450 lbf/ft for Retained Height 10 ft, the page's opening figures; on the metric page, 3 m gives 48.8 kN/m. Sources are cited below.

## Inputs

A length, area or volume is entered with its unit. The page opens on the values below: a metric reader sees the metric column, a US customary reader the other.

| Input | id | Opens at (metric) | Opens at (US customary) | Accepts |
|---|---|---|---|---|
| Retained Height | `retainedHeight` | 3 m | 10 ft | mm, cm, m, in, ft, yd; range 0.3–10 m |
| Earth Pressure Coefficient | `coefficientSource` | At rest, from the friction angle (Eurocode 7 9.5.2) | At rest, from the friction angle (Eurocode 7 9.5.2) | `at-rest`, `entered` |
| Effective Friction Angle φ′ (degrees) | `frictionAngle` | 30 | 30 | range 15–45 |
| Overconsolidation Ratio (OCR) | `overconsolidationRatio` | 1 | 1 | range 1–4 |
| Earth Pressure Coefficient K | `coefficient` | 0.5 | 0.5 | range 0.1–1.5 |
| Moist Unit Weight Above the Water Table (γ) | `moistUnitWeight` | 19 kN/m³ | 120.952 pcf | knm3, pcf_weight; range 14–23 kN/m³ |
| Saturated Unit Weight Below the Water Table (γsat) | `saturatedUnitWeight` | 20 kN/m³ | 127.318 pcf | knm3, pcf_weight; range 15–24 kN/m³ |
| Depth to the Water Table Below the Ground Surface | `waterTableDepth` | 1.5 m | 5 ft | mm, cm, m, in, ft, yd; range 0–10 m |
| Uniform Surcharge at the Surface | `surcharge` | 0 kPa | 0 psf | pa, kpa, mpa, psi, psf, in_wc; range 0–50000 Pa |

- **Retained Height**: The height of soil against the wall, from the base slab to the ground surface behind it.
- **Earth Pressure Coefficient**: At rest for a wall held by the floor at its head; an entered value for anything else the designer has set.
- **Effective Friction Angle φ′ (degrees)**: The drained friction angle of the retained soil, from the ground investigation.
- **Overconsolidation Ratio (OCR)**: 1 for normally consolidated soil and placed fill; higher for ground that was once under more load.
- **Earth Pressure Coefficient K**: The coefficient the design uses, applied to the effective vertical stress.
- **Moist Unit Weight Above the Water Table (γ)**: The weight of the retained soil as it is in service, water in the pores included.
- **Saturated Unit Weight Below the Water Table (γsat)**: The weight of the soil with its voids full, used below the water table.
- **Depth to the Water Table Below the Ground Surface**: How far below the retained surface the design water level sits; the full height or more means no water on the wall.
- **Uniform Surcharge at the Surface**: A load spread over the ground behind the wall — a drive, stored material, a building's floor.

`frictionAngle` applies only when `coefficientSource` is `at-rest`.
`overconsolidationRatio` applies only when `coefficientSource` is `at-rest`.
`coefficient` applies only when `coefficientSource` is `entered`.

## The answer on the opening values

Worked exactly as the page works it, on the values each system opens on.

### Metric

| Result | Value |
|---|---|
| **Total thrust on the wall per unit run** | 48.8 kN/m |
| At-rest coefficient K0 | 0.5 |
| Soil pressure at the base | 21.89 kN/m² |
| Water pressure at the base | 14.72 kN/m² |
| Total pressure at the base | 36.61 kN/m² |
| Soil thrust per unit run | 37.79 kN/m |
| Water thrust per unit run | 11.04 kN/m |
| Height of the resultant above the base | 0.94 m |

### US customary

| Result | Value |
|---|---|
| **Total thrust on the wall per unit run** | 3,450 lbf/ft |
| At-rest coefficient K0 | 0.5 |
| Soil pressure at the base | 464.55 psf |
| Water pressure at the base | 312.25 psf |
| Total pressure at the base | 776.8 psf |
| Soil thrust per unit run | 2,673.27 lbf/ft |
| Water thrust per unit run | 780.62 lbf/ft |
| Height of the resultant above the base | 3.13 ft |

- Confidence: medium.

## How it is worked out

At rest: the soil stays where it was placed, which is the state of a wall propped by the floor at its head. A wall genuinely free to lean away could use the lower active coefficient, but only if it can move enough to earn it. Below the water table the soil contributes only its buoyant weight times the coefficient, and the water acts on top of it at full hydrostatic pressure.

The working the page shows, in order: At-rest coefficient K0; Soil pressure at the base; Water pressure at the base; Total pressure at the base; Soil thrust per unit run; Water thrust per unit run; Height of the resultant above the base; then total thrust on the wall per unit run.

The method, derived in full:

- [Lateral Earth Pressure and the Wall That Resists It](https://craftquantities.com/methodology/lateral-earth-pressure/): Why one soil has three pressures that differ ninefold, why the resultant acts a third of the way up rather than halfway, and why water is what actually fails retaining walls.

What this calculation does not cover:

- Characteristic, unfactored pressures for a screening check. A design applies the partial or load factors of the code in force, and the structural engineer sets the design water level and the coefficient the wall is designed to.
- Horizontal ground behind the wall. A slope rising away from the wall increases the at-rest coefficient — Eurocode 7 multiplies it by (1 + sin β) — and is not modelled here.
- Compacting backfill in layers against a propped wall can lock in pressures above the at-rest figure near the top of the wall. AASHTO LRFD 3.11 and CIRIA C760 set out methods for it; this page does not add them.
- The water is static and the soil's cohesion is ignored. Seepage towards a drained wall changes the pore pressures, and a line load or strip footing close to the wall adds pressure that a uniform surcharge does not represent.

A professional must decide:

- Characteristic, unfactored pressures for a screening check. A design applies the partial or load factors of the code in force, and the structural engineer sets the design water level and the coefficient the wall is designed to.
- Structure: sizes, thicknesses, spans, reinforcement and bearing are a structural engineer's or the building official's decision. This is a quantity, not a design.

## Sources

As the calculator cites them (sources checked 2026-09-22):

- BS EN 1997-1 (Eurocode 7), 9.5.2: for a horizontal ground surface the at-rest coefficient is K0 = (1 − sin φ′) × √OCR, not to be used for very high overconsolidation ratios; with OCR = 1 it is Jaky's relation, K0 = 1 − sin φ′
- Effective-stress earth pressure with the pore water on its own line: horizontal pressure = K × σ′v on the soil skeleton plus γw × depth below the water table, the water taking no earth-pressure coefficient because it has no shear strength (Craig's Soil Mechanics; CIRIA C760); IBC 1610.1 requires at-rest pressure for walls restrained from moving at the top

The site's pages for the documents these name:

- [International Building Code](https://craftquantities.com/standards/icc/ibc/)

A code or standard has force only where a jurisdiction has adopted it, usually with local amendments; check what is in force with the authority where you build.

## Questions answered on the page

**Why at-rest pressure and not active pressure on a basement wall?**

Active pressure is the lower value a soil falls to when the wall moves away from it far enough to let it shear. A basement wall propped by the ground-floor slab cannot move, so the soil stays at rest, and IBC 1610.1 says so directly: walls restrained at the top are designed for at-rest pressure. At a friction angle of 30 degrees the difference is 0.5 against about 0.33 — half as much again.

**Why is the water carried separately instead of using the saturated unit weight?**

Because water has no shear strength, so no earth-pressure coefficient reduces it. Below the water table the soil pushes with its buoyant weight times the coefficient and the water pushes at full pressure on top. On three metres of saturated soil at a coefficient of 0.33 that is 10.1 kPa (211 psf) of soil and 29.4 kPa (614 psf) of water. Putting the saturated weight on the soil line counts the water twice; using the moist weight and forgetting the water altogether gives less than half the real load.

**What does the overconsolidation ratio change?**

Ground that was once under more load than it carries now holds more of its horizontal stress. Eurocode 7 raises the at-rest coefficient by the square root of the ratio, so an OCR of 2 lifts it by about 41 per cent. Placed and compacted fill is normally taken as 1; an overconsolidated clay is a figure for the ground investigation to give.

**Where does the thrust act?**

At the height of the resultant shown in the breakdown. A triangle of pressure acts a third of the way up, a uniform surcharge half way up, and a wall with water against it has more of its load low down, which moves the resultant towards the base. The bending in the wall and the reactions at the slab and the base follow from that height and the span.

## Related calculators

- [Rankine Active Earth Pressure with Surcharge Calculator](https://craftquantities.com/calculators/materials-quantities/active-pressure-surcharge-calculator/)
- [Rankine Passive Earth Pressure Calculator](https://craftquantities.com/calculators/materials-quantities/rankine-passive-pressure-calculator/)
- [Soil Phase Relationships Calculator (Unit Weights and Degree of Saturation)](https://craftquantities.com/calculators/materials-quantities/soil-phase-relationships-calculator/)
- [Excavation Shoring Lateral Active Soil Pressure Calculator (Rankine)](https://craftquantities.com/calculators/heavy-civil/shoring-active-pressure-calculator/)

## Run it from a program

- REST: `GET https://api.craftquantities.com/v1/calculate/basement-wall-at-rest-pressure-calculator` with each input as a query parameter, a length, area or volume with its unit; `https://api.craftquantities.com/v1/describe/basement-wall-at-rest-pressure-calculator` lists the inputs.
- MCP: the `calculate` tool at https://api.craftquantities.com/mcp with `slug` `basement-wall-at-rest-pressure-calculator`.
- Definition and test vectors: https://craftquantities.com/api/v1/calculators/basement-wall-at-rest-pressure-calculator.json

---
Source: https://craftquantities.com/calculators/materials-quantities/basement-wall-at-rest-pressure-calculator/