# Sleeper Retaining Wall Calculator (Sleepers, Steel Posts and Post Concrete)

> Sleepers, steel posts and post-hole concrete for a timber or concrete sleeper retaining wall, from the maker's or engineer's post centres and embedment.

Page: https://craftquantities.com/calculators/landscaping-outdoor/sleeper-retaining-wall-calculator/ (calculator). This is the page's Markdown copy; the HTML page is the canonical version.

Version 1.0.0, sources checked 2026-10-05, 3 published test vectors.

Sleepers for the wall: 15 sleepers for Wall Length 19.5 ft, Wall Height 39 in and Sleeper Length 78.74 in, the page's opening figures; on the metric page, 6 m, 1000 mm and 2000 mm give 15 sleepers. Source: Outback Sleepers, Installation Guide.

## Inputs

A length, area or volume is entered with its unit. The page opens on the values below: a metric reader sees the metric column, a US customary reader the other.

| Input | id | Opens at (metric) | Opens at (US customary) | Accepts |
|---|---|---|---|---|
| Wall Length | `wallLength` | 6 m | 19.5 ft | mm, cm, m, in, ft, yd; range 0.5–200 m |
| Wall Height (bottom of the lowest sleeper to the top) | `wallHeight` | 1000 mm | 39 in | mm, cm, m, in, ft, yd; range 0.1–4 m |
| Sleeper Length | `sleeperLength` | 2000 mm | 78.7402 in | mm, cm, m, in, ft, yd; range 0.3–4 m |
| Sleeper Face Height | `sleeperHeight` | 200 mm | 7.87402 in | mm, cm, m, in, ft, yd; range 0.05–0.5 m |
| Post Centres | `postSpacing` | 2010 mm | 79.1339 in | mm, cm, m, in, ft, yd; range 0.3–4 m |
| Post Depth in the Ground (embedment) | `embedment` | 1000 mm | 40 in | mm, cm, m, in, ft, yd; range 0.1–4 m |
| Post Hole Diameter | `holeDiameter` | 450 mm | 18 in | mm, cm, m, in, ft, yd; range 0.1–1.5 m |
| Post Hole Depth | `holeDepth` | 1100 mm | 44 in | mm, cm, m, in, ft, yd; range 0.1–4.5 m |
| Concrete Bag Weight | `bagMass` | 20 kg | 80 lb | kg, lb, t, ton; range 5–50 kg |

- **Wall Length**: The length of one straight run of wall, from the centre of the first post to the centre of the last.
- **Wall Height (bottom of the lowest sleeper to the top)**: The height of sleepers above the bottom of the lowest course, which is the soil the wall holds back plus any course set below the ground.
- **Sleeper Length**: The length of one sleeper as sold, which with the post centres sets how many fit a course.
- **Sleeper Face Height**: How tall one sleeper stands on its edge in the wall, which sets how many courses reach the height.
- **Post Centres**: The distance from the centre of one post to the centre of the next, as the sleeper maker or the engineer sets it.
- **Post Depth in the Ground (embedment)**: How far each post goes down into its concrete footing, from the maker's guide for this height or from an engineer.
- **Post Hole Diameter**: The diameter of the augered hole each post is concreted into, as the maker or the engineer gives it.
- **Post Hole Depth**: How deep each hole is dug, usually a little deeper than the post goes so concrete closes under the post.
- **Concrete Bag Weight**: The weight printed on the bag of pre-mixed concrete you will buy, such as 20 kg (44 lb) or 80 lb (36 kg).

## The answer on the opening values

Worked exactly as the page works it, on the values each system opens on.

### Metric

| Result | Value |
|---|---|
| **Sleepers for the wall** | 15 sleepers |
| Courses of sleepers | 5 courses |
| Bays between posts, one sleeper a course in each | 3 bays |
| Sleepers cut to fit their bay | 5 sleepers |
| Last bay, post centre to post centre | 1,980 mm |
| Height of the stacked courses | 1,000 mm |
| Top course above the height entered, posts taken up to it | 0 mm |
| Steel posts in all | 4 posts |
| End posts, C section | 2 posts |
| Intermediate posts, H section | 2 posts |
| Length of each post, stacked courses plus embedment | 2 m |
| Concrete in each post hole | 0.17 m³ |
| Concrete for all the post holes | 0.7 m³ |
| Bags of pre-mixed concrete | 75 bags |

### US customary

| Result | Value |
|---|---|
| **Sleepers for the wall** | 15 sleepers |
| Courses of sleepers | 5 courses |
| Bays between posts, one sleeper a course in each | 3 bays |
| Sleepers cut to fit their bay | 5 sleepers |
| Last bay, post centre to post centre | 75.73 in |
| Height of the stacked courses | 39.37 in |
| Top course above the height entered, posts taken up to it | 0.37 in |
| Steel posts in all | 4 posts |
| End posts, C section | 2 posts |
| Intermediate posts, H section | 2 posts |
| Length of each post, stacked courses plus embedment | 6.61 ft |
| Concrete in each post hole | 6.48 ft³ |
| Concrete for all the post holes | 25.92 ft³ |
| Bags of pre-mixed concrete | 44 bags |

## How it is worked out

Counted the way the maker's own calculator counts a straight wall: one sleeper a course in every bay, a post at every joint, a C section at each end and H sections between. The post section, the centres, the embedment and the hole are the maker's or an engineer's figures for this wall in this ground; the page multiplies them out and does not choose them, and a wall below a slope, a driveway or a building needs an engineer at any height.

The working the page shows, in order: Courses of sleepers; Bays between posts, one sleeper a course in each; Sleepers cut to fit their bay; Last bay, post centre to post centre; Height of the stacked courses; Top course above the height entered, posts taken up to it; Steel posts in all; End posts, C section; Intermediate posts, H section; Length of each post, stacked courses plus embedment; Concrete in each post hole; Concrete for all the post holes; Bags of pre-mixed concrete; then sleepers for the wall.

The method, derived in full:

- [Spacing, Pitch and the Count That Follows](https://craftquantities.com/methodology/spacing-pitch-and-count/): Why a run divided by a spacing gives the number of gaps and not the number of things, why the division rounds up rather than to nearest, and what the leftover bay at the end does to both.

What this calculation does not cover:

- A count of materials, never a design. The post section, the post centres, how deep the posts go, the hole and the concrete are the sleeper maker's published figures for this height in this ground, or an engineer's, and the page multiplies them out. The one case it opens on, Outback Sleepers' 1 m (3.28 ft) wall with holes 450 mm (17.7 in) across and 1,100 mm (43.3 in) deep, is given in the maker's guide with the words 'to be confirmed by a qualified engineer'.
- What the wall holds back matters more than how tall it is. The maker's engineering for its sleepers assumes no heavy surcharge, meaning no existing retaining wall, structure or building within twice the wall height, a finished slope above the wall flatter than 1 vertical to 10 horizontal, and a surcharge of 5 kPa (104 psf). A wall below a slope, beside a driveway or parking, or within twice its height of a house, a shed or a pool needs an engineer at any height.
- Drainage is not counted. Outback's guide puts a plastic membrane behind the sleepers, an agricultural pipe or strip drain along the back of the base and 20 mm (0.79 in) gravel over the pipe, and keeps machines off the backfill within three quarters of the wall height; a wall that holds water is pushed far harder than one that drains.
- One straight run of one height, built one way. Run each straight length on its own and add them: at a corner the two runs each count an end post where the wall takes one corner post, and a wall that steps down a slope changes its courses bay by bay. A wall of sleepers stacked with staggered joints and fixed to one another or to timber posts, or of sleepers stood on end, is not this system and needs a count of its own.
- The concrete is each hole's full cylinder, filled to ground level as the maker's guide draws it. Nothing is taken off for the steel post, a thin section that displaces little, and nothing is added for a hole dug oversize or caving in loose ground. Bags are counted at the site's standard pre-mix yield, rounded up once across the wall; a fast-setting post mix or a different bag can yield otherwise, so read the bag, and for a long wall weigh up ready-mixed concrete instead.
- Timber sleepers bring questions the count cannot answer: whether the timber is treated for in-ground contact, and how far it may span between posts at this height without bending, are the timber supplier's or the engineer's to state. The post centres entered are taken as already settled.
- Approval is a separate question. Outback says structures over 1 m (3.28 ft) need council approval and site-specific engineering; whether a lower wall needs approval is for the council, building control or the building department where it is built to say, so ask before it goes near a boundary, a building or a road.

A professional must decide:

- A count of materials, never a design. The post section, the post centres, how deep the posts go, the hole and the concrete are the sleeper maker's published figures for this height in this ground, or an engineer's, and the page multiplies them out.
- What the wall holds back matters more than how tall it is. The maker's engineering for its sleepers assumes no heavy surcharge, meaning no existing retaining wall, structure or building within twice the wall height, a finished slope above the wall flatter than 1 vertical to 10 horizontal, and a surcharge of 5 kPa (104 psf).
- Structure: sizes, thicknesses, spans, reinforcement and bearing are a structural engineer's or the building official's decision. This is a quantity, not a design.

## Sources

As the calculator cites them (sources checked 2026-10-05):

- Outback Sleepers, Installation Guide — Concrete Sleepers: holes at 2,010 mm centres for 2.0 m sleepers and 2,410 mm for 2.4 m sleepers, a similar 10 mm allowance for other lengths; hole diameter at least 450 mm for a one metre high wall, to be confirmed by a qualified engineer; for a one metre wall, post holes dug 1,100 mm deep, drawn with 1,000 mm of post above the ground, 1,000 mm in the hole and 100 mm of concrete under it; for all walls over 1 m, pier depth to be confirmed by a qualified engineer; a C section post drawn at the end of the run and H sections between; a plastic membrane behind the wall, an AG pipe or strip drain at the bottom of the wall covered in 20 mm gravel; no equipment over the backfill within 75% of the wall height; designs for typical soil conditions, and for walls over 1 metre independent engineering advice for the site <https://www.outbacksleepers.com.au/documents-downloads/>
- Outback Sleepers, information for specifiers: sleepers in 2 m and 2.4 m lengths, 200 mm high, in a range of thicknesses; walls 600 mm high or less set a minimum of 600 mm into the ground; structures over 1 m in height require council approval and site-specific engineering; steel lengths and sizes to be confirmed by the site engineer <https://www.outbacksleepers.com.au/information-specifiers/>
- Outback Sleepers, retaining wall calculator: number of sleepers = (wall height ÷ 0.2) × (wall length ÷ 2), number of steel posts = (wall length ÷ 2) + 1, using the standard 2 m sleeper on a straight wall of constant height; the customer checks product suitability and seeks council approval and engineering advice where required <https://www.outbacksleepers.com.au/retaining-wall-calculator/>
- Wallbridge Gilbert Aztec for Outback Sleepers, drawing WAD150933-S01 revision 5 (3 July 2020), concrete sleepers, 2,000 mm long: 200 mm high, 75 mm thick for walls up to 2.0 m, 100 mm to 3.0 m and 110 mm to 4.0 m; suitable only where the wall carries no heavy surcharge (no retaining walls, structures or buildings within twice the wall height) and the finished surface above it is flatter than 1 vertical in 10 horizontal; assumed soil 18 kN/m³ and 30°, surcharge 5 kPa; hand compaction only within 0.75 of the wall height; at least 25 mm of end bearing at each end of a sleeper; steel posts and concrete pier footings by others <https://www.outbacksleepers.com.au/documents-downloads/>
- Outback Sleepers, steel H-channel posts (NSW): 100 UC 14 galvanised I sections from 600 to 5,000 mm long and 150 UC 23 from 600 to 8,000 mm, hot-dip galvanised, for concrete sleeper retaining walls <https://www.outbacksleepers.com.au/products/h-channel-posts-nsw/>
- Bag yield: the Concrete Bag Calculator's standard published yield for pre-mixed concrete, 0.0075 cubic ft per pound of dry mix (0.60 cubic ft from an 80 lb bag, about 9.4 litres from a 20 kg bag); the yield printed on the bag governs

A code or standard has force only where a jurisdiction has adopted it, usually with local amendments; check what is in force with the authority where you build.

## Questions answered on the page

**How many sleepers and posts does a sleeper retaining wall need?**

The page's 6 m (19.7 ft) run of 1 m (3.28 ft) wall in 2.0 m (6.56 ft) sleepers 200 mm (7.87 in) high takes 15 sleepers and 4 posts: one sleeper a course in each bay between posts. Divide the run into bays at the post centres and the height into courses at the sleeper's face height, rounding both up. With posts at 2,010 mm (79.1 in) centres that is 3 bays and 5 courses, and a short end bay whose 5 sleepers are cut by about 30 mm (1.2 in). Outback Sleepers' own calculator does the same count for its 2 m (6.56 ft) sleepers, sleepers equal to height ÷ 0.2 times length ÷ 2 and posts equal to length ÷ 2 plus 1.

**How deep do the posts of a sleeper wall go?**

As deep as the maker's table or the engineer says for the height and the ground, which is why it is a field and not a rule here. Outback Sleepers' figures are the one published case: walls 600 mm (23.6 in) high or less set at least 600 mm (23.6 in) into the ground, and a 1 m (3.28 ft) wall with 1,000 mm (39.4 in) of post in a hole 1,100 mm (43.3 in) deep and at least 450 mm (17.7 in) across. Over 1 m (3.28 ft) the maker says the pier depth is for a qualified engineer to confirm.

**Why C posts at the ends and H posts in between?**

An H section has a channel on each side, so the sleepers of two neighbouring bays drop in from either side of one post. The last post of a run only has sleepers on one side, so it is a C section, a single channel facing the wall. A corner takes a corner post rather than the two end posts that two separate runs would each count, which is why the page asks for one straight run at a time.

**Do I need an engineer for a sleeper retaining wall?**

Over 1 m (3.28 ft), yes, by the maker's own guidance, which also says a structure that tall needs council approval. Below that, the maker's engineering still only holds for level ground behind the wall, a slope above it flatter than 1 vertical to 10 horizontal, and nothing heavy near the top: no building, structure or other retaining wall within twice the wall height. A driveway, a house footing or a sloping bank behind the wall calls for an engineer whatever the height. Whether a lower wall needs approval is for the council, building control or the building department where it is built.

**What kind of wall does this count, and what does it not?**

One system: sleepers dropped between galvanised steel posts set in concrete, an H section between bays and a C section at each end of a run, as Outback Sleepers sells its concrete sleeper walls; the same count serves timber sleepers fitted between such posts. It does not count a wall of sleepers stacked with staggered joints and fixed to one another or to timber posts, or sleepers stood on end in a trench; those are built and counted differently. The page opens on the Australian maker's own sleeper in both unit systems, because no sleeper for this system is made to an inch size. A reader in the US should know that 'sleepers' there more often means the wood strips laid on a concrete slab or a roof to carry a floor or a deck, which are not a retaining wall at all.

**How much concrete goes in each post hole?**

About 0.175 m³ (6.18 ft³) for the page's 450 mm (17.7 in) hole 1,100 mm (43.3 in) deep: the hole's whole volume, π × radius² × depth, because it is filled to the ground. That is about 18.7 bags of 20 kg (44 lb) at the site's standard yield. The steel post is not taken off, since an H or C section is thin steel around open channels, unlike the solid timber post the Post Hole Concrete Calculator deducts.

## Related calculators

- [Retaining Wall Block Calculator](https://craftquantities.com/calculators/materials-quantities/retaining-wall-block-calculator/)
- [Retaining Wall Drainage Gravel Calculator](https://craftquantities.com/calculators/auto-utility/retaining-wall-drainage-gravel-calculator/)
- [Post Hole Concrete Calculator](https://craftquantities.com/calculators/materials-quantities/post-hole-concrete-calculator/)
- [Concrete Bag Calculator](https://craftquantities.com/calculators/materials-quantities/concrete-bag-calculator/)

## Run it from a program

- REST: `GET https://api.craftquantities.com/v1/calculate/sleeper-retaining-wall-calculator` with each input as a query parameter, a length, area or volume with its unit; `https://api.craftquantities.com/v1/describe/sleeper-retaining-wall-calculator` lists the inputs.
- MCP: the `calculate` tool at https://api.craftquantities.com/mcp with `slug` `sleeper-retaining-wall-calculator`.
- Definition and test vectors: https://craftquantities.com/api/v1/calculators/sleeper-retaining-wall-calculator.json

---
Source: https://craftquantities.com/calculators/landscaping-outdoor/sleeper-retaining-wall-calculator/
Craft Quantities: free to read, cite and link to; the pages are not licensed for republication. Quantities only: no prices, no design and no certification.
