# Catch-Can Test Uniformity and Rate Calculator

> A zone's measured precipitation rate and low-quarter distribution uniformity from a catch-can test, with the run-time multiplier the uniformity implies.

Page: https://craftquantities.com/calculators/landscaping-outdoor/catch-can-distribution-uniformity-calculator/ (calculator). This is the page's Markdown copy; the HTML page is the canonical version.

Version 1.0.1, sources checked 2026-09-02, 2 published test vectors.

Measured precipitation rate: 1.32 in/h for Average Catch Volume Across All Cans 68, Average Catch of the Lowest Quarter of Cans 52 and Test Run Duration 15, the page's opening figures; on the metric page, 68, 52 and 15 give 34.6 mm/h. Sources are cited below.

## Inputs

A length, area or volume is entered with its unit. The page opens on the values below: a metric reader sees the metric column, a US customary reader the other.

| Input | id | Opens at (metric) | Opens at (US customary) | Accepts |
|---|---|---|---|---|
| Average Catch Volume Across All Cans (mL) | `averageCatchVolume` | 68 | 68 | range 1–2000 |
| Average Catch of the Lowest Quarter of Cans (mL) | `lowQuarterCatchVolume` | 52 | 52 | range 0.5–2000 |
| Catch Can Throat Diameter | `canThroatDiameter` | 100 mm | 4 in | mm, cm, m, in, ft, yd; range 0.03–0.4 m |
| Test Run Duration (minutes) | `runMinutes` | 15 | 15 | range 1–240 |
| Number of Cans in the Grid | `canCount` | 24 | 24 | range 4–200 |

- **Average Catch Volume Across All Cans (mL)**: Add every can's measured catch together and divide by the number of cans.
- **Average Catch of the Lowest Quarter of Cans (mL)**: Sort the readings, take the driest quarter of them, and average just those.
- **Catch Can Throat Diameter**: The internal diameter of the opening each can collects through.
- **Test Run Duration (minutes)**: How long the zone ran while the cans were collecting.
- **Number of Cans in the Grid**: How many catch devices were set out across the zone.

## The answer on the opening values

Worked exactly as the page works it, on the values each system opens on.

### Metric

| Result | Value |
|---|---|
| **Measured precipitation rate** | 34.6 mm/h |
| Low-quarter distribution uniformity | 76.47 % |
| Average catch depth over the test run | 8.66 mm |
| Run-time multiplier implied by the uniformity | 1.31 multiplier |
| Throat area of one can | 0.01 m² |
| Cans forming the low quarter | 6 cans |

### US customary

| Result | Value |
|---|---|
| **Measured precipitation rate** | 1.32 in/h |
| Low-quarter distribution uniformity | 76.47 % |
| Average catch depth over the test run | 0.33 in |
| Run-time multiplier implied by the uniformity | 1.31 multiplier |
| Throat area of one can | 0.09 sq ft |
| Cans forming the low quarter | 6 cans |

## How it is worked out

The driest quarter of the ground is receiving a high proportion of the average, so run times set from the average will not leave dry patches behind.

The working the page shows, in order: Low-quarter distribution uniformity; Average catch depth over the test run; Run-time multiplier implied by the uniformity; Throat area of one can; Cans forming the low quarter; then measured precipitation rate.

The method, derived in full:

- [Coverage Rate and Spread](https://craftquantities.com/methodology/coverage-rate-and-spread/): How a datasheet figure becomes an order quantity, why it is quoted per coat and calculated for a smooth plane, and what a real substrate does to it.

What this calculation does not cover:

- Describes the conditions on the day. Wind, supply pressure and a partially blocked nozzle all move the result, and a test run at dawn does not describe a zone that normally waters at midday.
- A grid too sparse to sample the overlap between heads reports a uniformity that is mostly noise, whatever the arithmetic says.
- Measures what lands in the cans, not what enters the soil. Runoff, interception by planting and infiltration limits are separate questions.

## Sources

As the calculator cites them (sources checked 2026-09-02):

- ISO 15886-3, Agricultural irrigation equipment — Sprinklers — Part 3: Characterization of distribution and test methods — sets out how sprinkler distribution is characterised under test
- ASABE/ICC 802, Landscape Irrigation Sprinkler and Emitter Standard — the reference frame for the published nozzle data a catch-can test is checking against
- Low-quarter distribution uniformity = mean catch of the lowest-scoring quarter of the cans ÷ mean catch of all cans; measured rate = mean catch volume ÷ can throat area ÷ test duration
- Catch volumes are entered in millilitres because that is the graduation a catch-can audit is read at in every market — the millilitre here belongs to the method rather than to a display preference, in the same way that a fixed test area belongs to the test that defines it

A code or standard has force only where a jurisdiction has adopted it, usually with local amendments; check what is in force with the authority where you build.

## Questions answered on the page

**Why the lowest quarter rather than the lowest single can?**

Because one can is an anecdote. A single low reading can come from a can that was knocked, shaded by a shrub, or sitting in the one spot a passing arc misses; averaging the driest quarter keeps the measure sensitive to genuinely dry ground while stopping a single outlier from condemning the zone. It is the measure the irrigation industry settled on precisely because it survives one bad can.

**How does the measured rate differ from the catalogue figure?**

Published nozzle data is laboratory data at a stated pressure, in still air, at a stated spacing. Your zone has the pressure the supply actually delivers, the spacing the site allowed, the wind that blows at the hour you irrigate, and whatever the last repair left behind. The grid measures all of that at once, which is why a commissioning figure is worth more than a designed one.

**What do I do with the run-time multiplier?**

Use it to see the cost of poor uniformity before you accept it. Multiplying the run time keeps the driest quarter alive, but it applies that same multiple everywhere else, so a mediocre uniformity turns directly into a water bill. On a zone that measures poorly, spend the effort on spacing, arc adjustment and matched nozzles first, and only fall back on the multiplier once the pattern is as good as the layout allows.

**Should the cans go where the heads are, or between them?**

Both, on a regular grid that ignores where the heads happen to be. A single head's own pattern is always heaviest near it, and the whole design premise of head-to-head coverage is that adjacent patterns average each other out. A grid placed to sample that overlap tells you whether the averaging is actually happening; a grid placed beside each head only tells you the heads are running.

## Related calculators

- [Dripline Precipitation Rate Calculator](https://craftquantities.com/calculators/landscaping-outdoor/dripline-application-rate-calculator/)
- [Sprinkler Head Spacing and Count Calculator](https://craftquantities.com/calculators/landscaping-outdoor/sprinkler-head-spacing-calculator/)
- [Irrigation Zone Calculator](https://craftquantities.com/calculators/landscaping-outdoor/irrigation-zone-calculator/)

## Run it from a program

- REST: `GET https://api.craftquantities.com/v1/calculate/catch-can-distribution-uniformity-calculator` with each input as a query parameter, a length, area or volume with its unit; `https://api.craftquantities.com/v1/describe/catch-can-distribution-uniformity-calculator` lists the inputs.
- MCP: the `calculate` tool at https://api.craftquantities.com/mcp with `slug` `catch-can-distribution-uniformity-calculator`.
- Definition and test vectors: https://craftquantities.com/api/v1/calculators/catch-can-distribution-uniformity-calculator.json

---
Source: https://craftquantities.com/calculators/landscaping-outdoor/catch-can-distribution-uniformity-calculator/
Craft Quantities: free to read, cite and link to; the pages are not licensed for republication. Quantities only: no prices, no design and no certification.
