# Vapor Barrier Calculator

> Estimate how many rolls of 6-mil poly vapor barrier you need for a crawlspace or basement.

Page: https://craftquantities.com/calculators/insulation-efficiency/vapor-barrier-calculator/ (calculator). This is the page's Markdown copy; the HTML page is the canonical version.

Version 1.1.0, sources checked 2026-09-17, 3 published test vectors.

Vapor barrier rolls needed: 2 rolls for Floor or Wall Area 1080 sq ft, the page's opening figures; on the metric page, 100 m² gives 2 rolls. Sources are cited below.

## Inputs

A length, area or volume is entered with its unit. The page opens on the values below: a metric reader sees the metric column, a US customary reader the other.

| Input | id | Opens at (metric) | Opens at (US customary) | Accepts |
|---|---|---|---|---|
| Floor or Wall Area | `area` | 100 m² | 1080 sq ft | m2, ft2, mm2, in2; range 0.01–5000 m² |
| Seam Overlap Allowance (%) | `overlapPercent` | 10 | 10 | range 0–40 |

- **Floor or Wall Area**: The total crawlspace floor or basement wall area to cover.
- **Seam Overlap Allowance (%)**: Sheet spent where seams overlap before they are taped.

## The answer on the opening values

Worked exactly as the page works it, on the values each system opens on.

### Metric

| Result | Value |
|---|---|
| **Vapor barrier rolls needed** | 2 rolls |
| Area to cover (with overlap allowance) | 110 m² |

### US customary

| Result | Value |
|---|---|
| **Vapor barrier rolls needed** | 2 rolls |
| Area to cover (with overlap allowance) | 1,188 sq ft |

## How it is worked out

The working the page shows, in order: Area to cover (with overlap allowance); then vapor barrier rolls needed.

The method, derived in full:

- [Rolls, Sheets and the Lap Between Them](https://craftquantities.com/methodology/rolls-sheets-and-laps/): Why covering an area with rolls is a strip count rather than a division, why the lap is bought twice over, and why turning the strips the other way can change the order.

What this calculation does not cover:

- The roll is fixed at a 10 ft x 100 ft (3 m x 30 m), 1,000 sq ft (93 m²) sheet. The calculator never asks what you are buying, so a 12, 16 or 20 ft wide roll, a 50 ft roll, or a reinforced 10-20 mil barrier will not divide into this count. Take the area figure from the breakdown and divide it by your own product's stated coverage.
- The overlap allowance is for flat-plane seams only. Nothing is added for turning the sheet up the foundation wall, wrapping piers and columns, sealing around penetrations, or the off-cuts an irregular crawlspace footprint produces. Measure and add those separately.
- Only the sheet is counted. Seam tape, mastic, mechanical fasteners and termination bar are not in this estimate.
- This is a quantity take-off, not a vapour-control design. It says nothing about the permeance, thickness or puncture class the barrier has to meet, or which face of the insulation it belongs on. In a cold store or an unvented crawlspace the wrong side traps moisture inside the assembly no matter how many rolls you order.
- It is not a radon or ground-gas membrane specification. Those are designed, jointed and verified systems with their own material, welding and testing requirements, and a 6-mil poly roll count does not substitute for one.

## Sources

As the calculator cites them (sources checked 2026-09-17):

- A standard 6-mil poly vapor barrier roll (10 ft x 100 ft) covers approximately 1,000 sq ft

A code or standard has force only where a jurisdiction has adopted it, usually with local amendments; check what is in force with the authority where you build.

## Questions answered on the page

**Why is this measured as an area rather than a perimeter?**

Because it is fighting DIFFUSION, which happens across every square metre of the surface at once. Water vapour moves from warm and humid towards cold and dry through the whole plane of a floor or a wall, driven by the pressure difference across it, and the material's job is to present a low permeance over that entire plane. That is why continuity is the property that matters and why a lap that is not taped is not a small defect: vapour finds the gap the way water finds a hole, and a barrier with a 2% opening performs far worse than 98% of a whole one. It is a fundamentally different problem from a thermal edge detail, which fights CONDUCTION along a line and is quantified by running metre.

**Why does a crawlspace need a vapor barrier at all?**

Bare soil constantly releases moisture into the crawlspace air, which can lead to wood rot, mold, and higher humidity in the living space above — a vapor barrier blocks that moisture at the source.

**Do seams need to overlap?**

Yes — seams are typically overlapped at least 6-12 in and often taped, which is what the seam overlap allowance in this estimate accounts for, 10% unless you change it.

**Is 6-mil poly the standard thickness?**

6-mil is a common standard for crawlspace vapor barriers, though some installers use heavier 10-20 mil reinforced barriers for better puncture resistance in high-traffic crawlspaces — coverage area math is the same regardless of thickness.

## Related calculators

- [R-Value Calculator](https://craftquantities.com/calculators/insulation-efficiency/r-value-calculator/)
- [Attic Insulation Upgrade Calculator](https://craftquantities.com/calculators/insulation-efficiency/attic-insulation-upgrade-calculator/)

## Run it from a program

- REST: `GET https://api.craftquantities.com/v1/calculate/vapor-barrier-calculator` with each input as a query parameter, a length, area or volume with its unit; `https://api.craftquantities.com/v1/describe/vapor-barrier-calculator` lists the inputs.
- MCP: the `calculate` tool at https://api.craftquantities.com/mcp with `slug` `vapor-barrier-calculator`.
- Definition and test vectors: https://craftquantities.com/api/v1/calculators/vapor-barrier-calculator.json

---
Source: https://craftquantities.com/calculators/insulation-efficiency/vapor-barrier-calculator/
Craft Quantities: free to read, cite and link to; the pages are not licensed for republication. Quantities only: no prices, no design and no certification.