# U-Factor Converter (BTU/hr·ft²·°F to W/m²K)

> Convert a US U-factor, from an NFRC label or an IECC or ASHRAE 90.1 table, into the metric U-value UK and European documents use, with R-value and RSI.

Page: https://craftquantities.com/calculators/insulation-efficiency/u-value-imperial-to-si-calculator/ (calculator). This is the page's Markdown copy; the HTML page is the canonical version.

Version 1.0.0, sources checked 2026-09-22, 3 published test vectors.

U-value: 1.7 W/m²K for U-factor 0.3, the page's opening figures. Sources are cited below.

## Inputs

A length, area or volume is entered with its unit. The page opens on the values below: a metric reader sees the metric column, a US customary reader the other.

| Input | id | Opens at (metric) | Opens at (US customary) | Accepts |
|---|---|---|---|---|
| U-factor (BTU/hr·ft²·°F) | `uValueImperial` | 0.3 | 0.3 | range 0.001–2 |

- **U-factor (BTU/hr·ft²·°F)**: Heat through one square foot for each degree Fahrenheit of difference, in BTU per hour, as US labels and code tables give it.

## The answer on the opening values

Worked exactly as the page works it, on the values each system opens on.

### Metric

| Result | Value |
|---|---|
| **U-value** | 1.7 W/m²K |
| BTU/hr·ft²·°F entered | 0.3 BTU/hr·ft²·°F |
| US R-value (1 ÷ U-factor) | 3.33 hr·ft²·°F/BTU |
| Thermal resistance, RSI (1 ÷ U) | 0.59 m²K/W |

### US customary

| Result | Value |
|---|---|
| **U-value** | 1.7 W/m²K |
| BTU/hr·ft²·°F entered | 0.3 BTU/hr·ft²·°F |
| US R-value (1 ÷ U-factor) | 3.33 hr·ft²·°F/BTU |
| Thermal resistance, RSI (1 ÷ U) | 0.59 m²K/W |

## How it is worked out

Multiplied by 5.678263, NIST's factor from BTU/(hr·ft²·°F) to W/(m²·K). Multiply a US U-factor by 5.678 for W/m²K. Invert within one system: 1 ÷ the US figure is the US R-value, 1 ÷ the metric figure is the RSI.

The working the page shows, in order: BTU/hr·ft²·°F entered; US R-value (1 ÷ U-factor); Thermal resistance, RSI (1 ÷ U); then u-value.

The method, derived in full:

- [Unit Conversion, Exactness and Rounding](https://craftquantities.com/methodology/unit-conversion-and-rounding/): Why most conversion factors carry no uncertainty at all, which ones hide a material assumption, and why converting a measurement can never make it more precise than it was.

## Sources

As the calculator cites them (sources checked 2026-09-22):

- NIST Guide to the SI (SP 811), Appendix B.8, factors listed alphabetically: to convert from British thermal unit (IT) per hour square foot degree Fahrenheit to watt per square meter kelvin, multiply by 5.678 263 E+00
- R = 1 ÷ U within one system: the reciprocal of a US U-factor is a US R-value, the reciprocal of a metric U-value is an RSI, each counting the inside and outside air films
- NFRC 100 window and door ratings, the International Energy Conservation Code and ANSI/ASHRAE/IES Standard 90.1 state their U-factors in BTU/(hr·ft²·°F)

A code or standard has force only where a jurisdiction has adopted it, usually with local amendments; check what is in force with the authority where you build.

## Questions answered on the page

**What is an NFRC U-0.30 window in W/m²K?**

About 1.70 W/m²K: 0.30 × 5.678. Going the other way, a European window declared at 1.4 W/m²K is about U-0.25 in the US unit.

**Why is the US figure so much smaller for the same wall?**

Because the imperial unit is the bigger one — a single unit of it equals 5.678 of the metric unit — so the same heat flow takes a smaller number to write. Nothing about the wall changes.

**Will the converted figure match a European declaration for the same window?**

Close, not exactly. NFRC 100 and BS EN ISO 10077 rate windows at different standard sizes and boundary conditions, so the two declared figures for one product can differ by more than the unit conversion.

## Related calculators

- [U-Value Metric to Imperial Converter (W/m²K to BTU/hr·ft²·°F)](https://craftquantities.com/calculators/insulation-efficiency/u-value-si-to-imperial-calculator/)
- [U-Value to R-Value Calculator](https://craftquantities.com/calculators/insulation-efficiency/u-value-to-r-value-calculator/)
- [Window Heat Loss Savings Calculator](https://craftquantities.com/calculators/insulation-efficiency/window-heat-loss-savings-calculator/)
- [Insulation Thickness for a Target U-Value Calculator (BS EN ISO 6946)](https://craftquantities.com/calculators/insulation-efficiency/insulation-thickness-target-u-value-calculator/)

## Run it from a program

- REST: `GET https://api.craftquantities.com/v1/calculate/u-value-imperial-to-si-calculator` with each input as a query parameter, a length, area or volume with its unit; `https://api.craftquantities.com/v1/describe/u-value-imperial-to-si-calculator` lists the inputs.
- MCP: the `calculate` tool at https://api.craftquantities.com/mcp with `slug` `u-value-imperial-to-si-calculator`.
- Definition and test vectors: https://craftquantities.com/api/v1/calculators/u-value-imperial-to-si-calculator.json

---
Source: https://craftquantities.com/calculators/insulation-efficiency/u-value-imperial-to-si-calculator/
Craft Quantities: free to read, cite and link to; the pages are not licensed for republication. Quantities only: no prices, no design and no certification.