# Thermal Bridge Heat Loss Calculator (ψ and χ Values)

> The heat lost through an element's thermal bridges, junctions as ψ times length and point bridges as χ times count, and what they add to its U-value.

Page: https://craftquantities.com/calculators/insulation-efficiency/thermal-bridge-heat-loss-calculator/ (calculator). This is the page's Markdown copy; the HTML page is the canonical version.

Version 1.0.0, sources checked 2026-09-22, 3 published test vectors.

Heat loss through the thermal bridges: 10.4 BTU/hr·°F for Area of the Element 1080 sq ft, U-Value of the Element Without the Bridges 0.04 BTU/(hr·ft²·°F) and Junction 1: Linear Thermal Transmittance ψ 0.03 BTU/hr·ft·°F, the page's opening figures; on the metric page, 100 m², 0.2 W/m²K and 0.05 W/m·K give 5.5 W/K. Sources are cited below.

## Inputs

A length, area or volume is entered with its unit. The page opens on the values below: a metric reader sees the metric column, a US customary reader the other.

| Input | id | Opens at (metric) | Opens at (US customary) | Accepts |
|---|---|---|---|---|
| Area of the Element | `area` | 100 m² | 1080 sq ft | m2, ft2, mm2, in2; range 1–100000 m² |
| U-Value of the Element Without the Bridges (0 to skip) | `baseU` | 0.2 W/m²K | 0.035222 BTU/(hr·ft²·°F) | w_m2k, btu_h_ft2_f; range 0–5 W/m²K |
| Junction 1: Linear Thermal Transmittance ψ | `psi1` | 0.05 W/m·K | 0.0288895 BTU/hr·ft·°F | psi_w_mk, psi_btu_h_ft_f; range 0–2 W/m·K |
| Junction 1: Length | `length1` | 40 m | 130 ft | mm, cm, m, in, ft, yd; range 0–10000 m |
| Junction 2: Linear Thermal Transmittance ψ (0 if none) | `psi2` | 0.1 W/m·K | 0.0577789 BTU/hr·ft·°F | psi_w_mk, psi_btu_h_ft_f; range 0–2 W/m·K |
| Junction 2: Length | `length2` | 20 m | 66 ft | mm, cm, m, in, ft, yd; range 0–10000 m |
| Junction 3: Linear Thermal Transmittance ψ (0 if none) | `psi3` | 0 W/m·K | 0 BTU/hr·ft·°F | psi_w_mk, psi_btu_h_ft_f; range 0–2 W/m·K |
| Junction 3: Length | `length3` | 0 m | 0 ft | mm, cm, m, in, ft, yd; range 0–10000 m |
| Junction 4: Linear Thermal Transmittance ψ (0 if none) | `psi4` | 0 W/m·K | 0 BTU/hr·ft·°F | psi_w_mk, psi_btu_h_ft_f; range 0–2 W/m·K |
| Junction 4: Length | `length4` | 0 m | 0 ft | mm, cm, m, in, ft, yd; range 0–10000 m |
| Point Bridges: Point Thermal Transmittance χ | `chi1` | 0.03 W/K | 0.056869 BTU/hr·°F | w_k, btu_h_f; range 0–5 W/K |
| Point Bridges: How Many | `count1` | 50 | 50 | range 0–100000 |
| Second Point Bridge: χ (0 if none) | `chi2` | 0 W/K | 0 BTU/hr·°F | w_k, btu_h_f; range 0–5 W/K |
| Second Point Bridge: How Many | `count2` | 0 | 0 | range 0–100000 |

- **Area of the Element**: The wall or roof area the bridges belong to, measured the way its U-value is.
- **U-Value of the Element Without the Bridges (0 to skip)**: The clear-field U-value, before any junction or bracket is counted.
- **Junction 1: Linear Thermal Transmittance ψ**: The junction's ψ-value, from a certified detail, a model or a published catalogue.
- **Junction 1: Length**: The length of that junction on this element.
- **Junction 2: Linear Thermal Transmittance ψ (0 if none)**: The junction's ψ-value, from a certified detail, a model or a published catalogue.
- **Junction 2: Length**: The length of that junction on this element.
- **Junction 3: Linear Thermal Transmittance ψ (0 if none)**: The junction's ψ-value, from a certified detail, a model or a published catalogue.
- **Junction 3: Length**: The length of that junction on this element.
- **Junction 4: Linear Thermal Transmittance ψ (0 if none)**: The junction's ψ-value, from a certified detail, a model or a published catalogue.
- **Junction 4: Length**: The length of that junction on this element.
- **Point Bridges: Point Thermal Transmittance χ**: The χ-value of one bracket, clip or fixing, from its manufacturer's model.
- **Point Bridges: How Many**: How many of those brackets or clips cross the insulation on this element.
- **Second Point Bridge: χ (0 if none)**: A second kind of point bridge — a balcony connector, a canopy fixing.
- **Second Point Bridge: How Many**: How many of the second kind.

## The answer on the opening values

Worked exactly as the page works it, on the values each system opens on.

### Metric

| Result | Value |
|---|---|
| **Heat loss through the thermal bridges** | 5.5 W/K |
| From the junctions (ψ × length) | 4 W/K |
| From the point bridges (χ × count) | 1.5 W/K |
| Added to the U-value by the bridges | 0.06 W/m²K |
| Effective U-value with the bridges | 0.26 W/m²K |

### US customary

| Result | Value |
|---|---|
| **Heat loss through the thermal bridges** | 10.4 BTU/hr·°F |
| From the junctions (ψ × length) | 7.57 BTU/hr·°F |
| From the point bridges (χ × count) | 2.84 BTU/hr·°F |
| Added to the U-value by the bridges | 0.01 BTU/(hr·ft²·°F) |
| Effective U-value with the bridges | 0.04 BTU/(hr·ft²·°F) |

## How it is worked out

The bridges' heat loss per degree is Σψ × L + Σχ; divided by the element's area it is what they add to the U-value. Multiply the total by a temperature difference for the heat itself.

The working the page shows, in order: From the junctions (ψ × length); From the point bridges (χ × count); Added to the U-value by the bridges; Effective U-value with the bridges; then heat loss through the thermal bridges.

The method, derived in full:

- [Thermal Resistance in Series](https://craftquantities.com/methodology/thermal-resistance-in-series/): Why R-values add but U-values do not, and why the assembly you build never performs like the assembly you specified.

What this calculation does not cover:

- The ψ- and χ-values are inputs, and they are only as good as their source: a certified detail, a model to BS EN ISO 10211 for that construction, or a published catalogue for a similar one. A default value from a table is usually larger than a modelled one, on purpose.
- A continuous girt or stud is not a point bridge; it is usually handled as a reduced layer resistance, which the thermal bridging calculator computes.
- ψ-values depend on which dimensions the U-values were measured to — internal or external — and must be used with areas measured the same way.

## Sources

As the calculator cites them (sources checked 2026-09-22):

- BS EN ISO 14683, Thermal bridges in building construction — Linear thermal transmittance; BS EN ISO 10211, Heat flows and surface temperatures — Detailed calculations: the heat loss of the bridges is Σψ × L + Σχ
- BRE BR 497, Conventions for calculating linear thermal transmittance and temperature factors
- ANSI/ASHRAE/IES Standard 90.1-2022, Section 5.5.5 and Appendix A Table A10.1: linear (ψ, Btu/h·ft·°F) and point (χ, Btu/h·°F) thermal bridges

A code or standard has force only where a jurisdiction has adopted it, usually with local amendments; check what is in force with the authority where you build.

## Questions answered on the page

**Why is a bracket a point and not an area?**

Because it is a single path for heat through the insulation, and its penalty is a fixed amount per bracket rather than a share of the wall. Forcing a discrete clip into an area-fraction method over- or under-states it depending on how the fraction was guessed; the manufacturer's χ-value times the count is the direct figure.

**How does this relate to a y-value?**

A y-value is the same total heat loss of the junctions divided by the total exposed area of the building, used as a single allowance in SAP. This page does that for one element: the bridges' W/K divided by its area.

**Do the values change between metric and US units?**

Only in their unit. ψ in W/m·K and in BTU/hr·ft·°F, χ in W/K and in BTU/hr·°F, describe the same detail, and every box follows the unit switch.

## Related calculators

- [Thermal Bridging Effective R-Value Calculator](https://craftquantities.com/calculators/insulation-efficiency/thermal-bridging-calculator/)
- [Continuous Insulation Thermal Bridging Calculator (Z-Furring)](https://craftquantities.com/calculators/materials-quantities/ci-thermal-bridging-calculator/)
- [Surface Temperature Factor (fRsi) Calculator (BS EN ISO 13788, BRE IP 1/06)](https://craftquantities.com/calculators/insulation-efficiency/surface-temperature-factor-frsi-calculator/)
- [Insulation Thickness for a Target U-Value Calculator (BS EN ISO 6946)](https://craftquantities.com/calculators/insulation-efficiency/insulation-thickness-target-u-value-calculator/)

## Run it from a program

- REST: `GET https://api.craftquantities.com/v1/calculate/thermal-bridge-heat-loss-calculator` with each input as a query parameter, a length, area or volume with its unit; `https://api.craftquantities.com/v1/describe/thermal-bridge-heat-loss-calculator` lists the inputs.
- MCP: the `calculate` tool at https://api.craftquantities.com/mcp with `slug` `thermal-bridge-heat-loss-calculator`.
- Definition and test vectors: https://craftquantities.com/api/v1/calculators/thermal-bridge-heat-loss-calculator.json

---
Source: https://craftquantities.com/calculators/insulation-efficiency/thermal-bridge-heat-loss-calculator/
Craft Quantities: free to read, cite and link to; the pages are not licensed for republication. Quantities only: no prices, no design and no certification.