# RSI to R-Value Calculator

> Convert a metric RSI rating into the IP R-value US product labels and codes are written in.

Page: https://craftquantities.com/calculators/insulation-efficiency/rsi-to-r-value-calculator/ (calculator). This is the page's Markdown copy; the HTML page is the canonical version.

Version 1.0.0, sources checked 2026-09-12, 4 published test vectors.

R-value: 19.9 h·ft²·°F/BTU for Thermal resistance 3.5, the page's opening figures. Sources are cited below.

## Inputs

A length, area or volume is entered with its unit. The page opens on the values below: a metric reader sees the metric column, a US customary reader the other.

| Input | id | Opens at (metric) | Opens at (US customary) | Accepts |
|---|---|---|---|---|
| Thermal resistance (RSI) (m²·K/W) | `rsi` | 3.5 | 3.5 | range 0.01–40 |

- **Thermal resistance (RSI) (m²·K/W)**: The RSI value from the label, the specification or the energy code.

## The answer on the opening values

Worked exactly as the page works it, on the values each system opens on.

### Metric

| Result | Value |
|---|---|
| **R-value** | 19.9 h·ft²·°F/BTU |
| RSI entered | 3.5 m²·K/W |
| Nearest whole R-value | 20 h·ft²·°F/BTU |
| IP U-factor (the reciprocal) | 0.05 BTU/h·ft²·°F |

### US customary

| Result | Value |
|---|---|
| **R-value** | 19.9 h·ft²·°F/BTU |
| RSI entered | 3.5 m²·K/W |
| Nearest whole R-value | 20 h·ft²·°F/BTU |
| IP U-factor (the reciprocal) | 0.05 BTU/h·ft²·°F |

## How it is worked out

1 RSI = 5.678263 R, so RSI × 5.678263 = R. Exact by definition. Where a code sets the target, quote that code's own figure rather than your conversion of the other one.

The working the page shows, in order: RSI entered; Nearest whole R-value; IP U-factor (the reciprocal); then r-value.

The method, derived in full:

- [Unit Conversion, Exactness and Rounding](https://craftquantities.com/methodology/unit-conversion-and-rounding/): Why most conversion factors carry no uncertainty at all, which ones hide a material assumption, and why converting a measurement can never make it more precise than it was.

What this calculation does not cover:

- A declared figure converted, not a measured one. Installation quality is outside it.
- Metric assembly figures more often include surface films than IP product figures do; check what each number already contains before comparing them.

## Sources

As the calculator cites them (sources checked 2026-09-12):

- NIST SP 811, Appendix B — thermal insulance: 1 m²·K/W = 5.678263 h·ft²·°F/BTU
- ASTM C168, Standard Terminology Relating to Thermal Insulation

A code or standard has force only where a jurisdiction has adopted it, usually with local amendments; check what is in force with the authority where you build.

## Questions answered on the page

**My label says RSI 3.52 — is that the same as R-20?**

It is R-19.99, which is why RSI 3.52 is the figure Canadian codes use where American ones say R-20. The pairing is deliberate rather than coincidental: the metric requirement was set by converting the imperial one and rounding to two decimals.

**Why does my converted answer not match the R on the same package?**

Usually rounding at the source. Manufacturers round the declared value in each market, sometimes downward for a compliance margin, so a product can carry RSI 2.11 on one face and R-12 on the other when the exact conversion is R-11.98. Take each market's declared figure as the one to quote in that market.

**Can I convert lambda straight to R-value?**

Not in one step, because lambda is per metre of material. Divide the thickness in metres by lambda to get RSI, then convert that. A 100 mm board at 0.035 W/m·K is 0.1 ÷ 0.035 = RSI 2.86, which is R-16.2.

**Does a higher R-value always mean a warmer building?**

Only up to the point where something else becomes the limit. Past roughly R-40 in a wall, air leakage, window area and thermal bridges dominate the heat loss, and further insulation buys progressively less. The conversion is exact; the benefit it implies is not.

## Related calculators

- [R-Value to RSI Calculator](https://craftquantities.com/calculators/insulation-efficiency/r-value-to-rsi-calculator/)
- [U-Value to R-Value Calculator](https://craftquantities.com/calculators/insulation-efficiency/u-value-to-r-value-calculator/)
- [Thermal Bridging Effective R-Value Calculator](https://craftquantities.com/calculators/insulation-efficiency/thermal-bridging-calculator/)

## Run it from a program

- REST: `GET https://api.craftquantities.com/v1/calculate/rsi-to-r-value-calculator` with each input as a query parameter, a length, area or volume with its unit; `https://api.craftquantities.com/v1/describe/rsi-to-r-value-calculator` lists the inputs.
- MCP: the `calculate` tool at https://api.craftquantities.com/mcp with `slug` `rsi-to-r-value-calculator`.
- Definition and test vectors: https://craftquantities.com/api/v1/calculators/rsi-to-r-value-calculator.json

---
Source: https://craftquantities.com/calculators/insulation-efficiency/rsi-to-r-value-calculator/
Craft Quantities: free to read, cite and link to; the pages are not licensed for republication. Quantities only: no prices, no design and no certification.