# R-Value to U-Value Calculator

> Convert thermal resistance (R-value) into thermal transmittance (U-value) for heat-loss calculations.

Page: https://craftquantities.com/calculators/insulation-efficiency/r-value-to-u-value-calculator/ (calculator). This is the page's Markdown copy; the HTML page is the canonical version.

Version 1.0.1, sources checked 2026-09-02, 2 published test vectors.

U-value: 0.0526 BTU/hr·ft²·°F for R-value 19, the page's opening figures. Sources are cited below.

## Inputs

A length, area or volume is entered with its unit. The page opens on the values below: a metric reader sees the metric column, a US customary reader the other.

| Input | id | Opens at (metric) | Opens at (US customary) | Accepts |
|---|---|---|---|---|
| R-value (hr·ft²·°F/BTU) | `rValue` | 19 | 19 | range 0.1–100 |

- **R-value (hr·ft²·°F/BTU)**: The assembly's total thermal resistance.

## The answer on the opening values

Worked exactly as the page works it, on the values each system opens on.

### Metric

| Result | Value |
|---|---|
| **U-value** | 0.0526 BTU/hr·ft²·°F |

### US customary

| Result | Value |
|---|---|
| **U-value** | 0.0526 BTU/hr·ft²·°F |

## How it is worked out

U = 1 ÷ R. The two are exact reciprocals of one another. R-values add across layers; U-values do not. Sum R first, then take the reciprocal once.

The method, derived in full:

- [Unit Conversion, Exactness and Rounding](https://craftquantities.com/methodology/unit-conversion-and-rounding/): Why most conversion factors carry no uncertainty at all, which ones hide a material assumption, and why converting a measurement can never make it more precise than it was.

What this calculation does not cover:

- The conversion trusts the number you type and cannot tell a whole-assembly R from a product label. Insulation, sheathing, cladding, linings, cavities and the interior and exterior surface films all have to be totalled before the reciprocal is taken; a batt's rated R entered on its own returns the U-value of a wall that does not exist.
- Thermal bridging is not in it. Studs, plates, headers, rim joists, cladding fasteners and metal furring carry heat around the insulation, so a framed assembly performs worse than the reciprocal of its clear-field R. That figure comes from a parallel-path or isothermal-planes calculation, not from this one.
- A U-value describes steady-state, one-dimensional conduction and nothing else. Air leakage, wind-washing through loose-fill, convection in unsealed cavities, moisture in the material, thermal mass and solar gain all sit outside it, so a heat loss worked out as U x A x deltaT is the conduction share of the load rather than the whole load.
- R-value is quoted at a rating temperature and does not hold across all service conditions. Foil-faced polyiso in particular delivers less R per inch as the assembly gets cold, and foam boards drift as their blowing agent ages, so the R that applies on a design winter night may not be the one printed on the board.
- This is arithmetic, not a compliance check. Energy codes set maximum U-factors against specifically defined assemblies, and windows and doors are rated as whole units including frame and edge-of-glass, so inverting a glazing R will not answer either question. Everything on this page is imperial: a metric U in W/m2K is roughly 5.68 times the imperial figure shown here.

## Sources

As the calculator cites them (sources checked 2026-09-02):

- Thermal transmittance is the reciprocal of thermal resistance: U = 1 / R
- Heat transfer through an assembly: Q = U x A x deltaT

A code or standard has force only where a jurisdiction has adopted it, usually with local amendments; check what is in force with the authority where you build.

## Questions answered on the page

**Why do heat-loss formulas use U rather than R?**

Because heat loss is proportional to transmittance, so Q equals U times area times temperature difference. Resistance is the more intuitive number for comparing insulation products, but transmittance is the one that multiplies cleanly through a heat-loss calculation.

**Can I add U-values across layers?**

No, and this is the classic error. R-values add in series; U-values do not. Sum the resistances of every layer first, then take the reciprocal once at the end. Adding U-values gives a badly wrong answer.

**Do air films count?**

Yes, and they are not trivial. Interior and exterior surface films contribute meaningful resistance, and an enclosed cavity adds more. Omitting them makes an assembly look worse than it performs.

## Related calculators

- [U-Value to R-Value Calculator](https://craftquantities.com/calculators/insulation-efficiency/u-value-to-r-value-calculator/)
- [R-Value Calculator](https://craftquantities.com/calculators/insulation-efficiency/r-value-calculator/)
- [Insulation Batt Calculator](https://craftquantities.com/calculators/insulation-efficiency/insulation-batt-calculator/)

## Run it from a program

- REST: `GET https://api.craftquantities.com/v1/calculate/r-value-to-u-value-calculator` with each input as a query parameter, a length, area or volume with its unit; `https://api.craftquantities.com/v1/describe/r-value-to-u-value-calculator` lists the inputs.
- MCP: the `calculate` tool at https://api.craftquantities.com/mcp with `slug` `r-value-to-u-value-calculator`.
- Definition and test vectors: https://craftquantities.com/api/v1/calculators/r-value-to-u-value-calculator.json

---
Source: https://craftquantities.com/calculators/insulation-efficiency/r-value-to-u-value-calculator/
Craft Quantities: free to read, cite and link to; the pages are not licensed for republication. Quantities only: no prices, no design and no certification.