# R-Value to RSI Calculator

> Convert an IP R-value into metric RSI, so a US insulation rating can be read against a Canadian or European specification.

Page: https://craftquantities.com/calculators/insulation-efficiency/r-value-to-rsi-calculator/ (calculator). This is the page's Markdown copy; the HTML page is the canonical version.

Version 1.0.0, sources checked 2026-09-12, 4 published test vectors.

Thermal resistance (RSI): 5.28 m²·K/W for R-value 30, the page's opening figures. Sources are cited below.

## Inputs

A length, area or volume is entered with its unit. The page opens on the values below: a metric reader sees the metric column, a US customary reader the other.

| Input | id | Opens at (metric) | Opens at (US customary) | Accepts |
|---|---|---|---|---|
| R-value (h·ft²·°F/BTU) | `rValue` | 30 | 30 | range 0.1–200 |

- **R-value (h·ft²·°F/BTU)**: The R-value printed on the product or called for by the specification.

## The answer on the opening values

Worked exactly as the page works it, on the values each system opens on.

### Metric

| Result | Value |
|---|---|
| **Thermal resistance (RSI)** | 5.28 m²·K/W |
| R-value entered | 30 h·ft²·°F/BTU |
| Metric U-value (the reciprocal) | 0.19 W/m²·K |
| IP U-factor (the reciprocal in IP) | 0.03 BTU/h·ft²·°F |

### US customary

| Result | Value |
|---|---|
| **Thermal resistance (RSI)** | 5.28 m²·K/W |
| R-value entered | 30 h·ft²·°F/BTU |
| Metric U-value (the reciprocal) | 0.19 W/m²·K |
| IP U-factor (the reciprocal in IP) | 0.03 BTU/h·ft²·°F |

## How it is worked out

1 RSI = 5.678263 R, so R ÷ 5.678263 = RSI. Exact by definition. Carry the unconverted figure on the record and the converted one in brackets.

The working the page shows, in order: R-value entered; Metric U-value (the reciprocal); IP U-factor (the reciprocal in IP); then thermal resistance (RSI).

The method, derived in full:

- [Unit Conversion, Exactness and Rounding](https://craftquantities.com/methodology/unit-conversion-and-rounding/): Why most conversion factors carry no uncertainty at all, which ones hide a material assumption, and why converting a measurement can never make it more precise than it was.

What this calculation does not cover:

- Converts a declared resistance, not an installed one. Compression, gaps and wind-washing all reduce what a batt delivers and none of them is visible here.
- Says nothing about thermal bridging. A framed wall's effective RSI is below the sum of its layers, often by a fifth or more.
- Ignores surface films and air spaces, which some published assembly figures include and others do not. Compare like with like before comparing numbers.

## Sources

As the calculator cites them (sources checked 2026-09-12):

- NIST SP 811, Appendix B — thermal insulance: 1 h·ft²·°F/BTU = 0.176110 m²·K/W
- ASTM C168, Standard Terminology Relating to Thermal Insulation (defines thermal resistance and its IP/SI forms)

A code or standard has force only where a jurisdiction has adopted it, usually with local amendments; check what is in force with the authority where you build.

## Questions answered on the page

**Why 5.678 and not something rounder?**

Because three conversions are stacked inside it. A square metre is 10.7639 square feet, a kelvin of difference is 1.8 degrees Fahrenheit, and a watt is 3.41214 BTU per hour. Multiply the first two and divide by the third and you get 5.678263. Nothing about it was chosen — it falls out of the units.

**Is RSI the same thing as a metric R-value?**

Yes, and the ambiguity is the reason this page exists. Canadian and European labels sometimes print RSI simply as "R", so a board marked R 1.76 in Europe and a board marked R-10 in the United States are the same product. Treat a bare R on a metric label as RSI until the units next to it say otherwise.

**Does converting the R-value give me the assembly's performance?**

No. It gives you the same claim in different units. A wall's effective resistance is lower than the sum of its layers wherever a stud, a fastener or a slab edge bridges the insulation, and that reduction is a separate calculation — not something a unit conversion can see.

**Which figure should go on the drawing?**

Whichever one the governing code is written in, with the other in brackets. Canadian codes call for RSI, US codes for R, and a drawing that carries only the converted figure invites somebody downstream to convert it back and land on a rounded number that no longer matches the product.

## Related calculators

- [RSI to R-Value Calculator](https://craftquantities.com/calculators/insulation-efficiency/rsi-to-r-value-calculator/)
- [R-Value to U-Value Calculator](https://craftquantities.com/calculators/insulation-efficiency/r-value-to-u-value-calculator/)
- [R-Value Calculator](https://craftquantities.com/calculators/insulation-efficiency/r-value-calculator/)

## Run it from a program

- REST: `GET https://api.craftquantities.com/v1/calculate/r-value-to-rsi-calculator` with each input as a query parameter, a length, area or volume with its unit; `https://api.craftquantities.com/v1/describe/r-value-to-rsi-calculator` lists the inputs.
- MCP: the `calculate` tool at https://api.craftquantities.com/mcp with `slug` `r-value-to-rsi-calculator`.
- Definition and test vectors: https://craftquantities.com/api/v1/calculators/r-value-to-rsi-calculator.json

---
Source: https://craftquantities.com/calculators/insulation-efficiency/r-value-to-rsi-calculator/
Craft Quantities: free to read, cite and link to; the pages are not licensed for republication. Quantities only: no prices, no design and no certification.