# R-Value Calculator

> Add up the R-values of layered materials in a wall, floor, or ceiling assembly to get the total insulating value.

Page: https://craftquantities.com/calculators/insulation-efficiency/r-value-calculator/ (calculator). This is the page's Markdown copy; the HTML page is the canonical version.

Version 1.0.1, sources checked 2026-09-02, 2 published test vectors.

Total assembly R-value: 15.8 R-value for Layer 1 R-Value 13, Layer 2 R-Value 1.5 and Layer 3 R-Value 0.45, the page's opening figures. Sources are cited below.

## Inputs

A length, area or volume is entered with its unit. The page opens on the values below: a metric reader sees the metric column, a US customary reader the other.

| Input | id | Opens at (metric) | Opens at (US customary) | Accepts |
|---|---|---|---|---|
| Layer 1 R-Value (e.g. batt insulation) | `layer1RValue` | 13 | 13 | range 0–60 |
| Layer 2 R-Value (e.g. sheathing) | `layer2RValue` | 1.5 | 1.5 | range 0–30 |
| Layer 3 R-Value (e.g. drywall) | `layer3RValue` | 0.45 | 0.45 | range 0–10 |

- **Layer 1 R-Value (e.g. batt insulation)**: The R-value of your main insulation layer, printed on the product.
- **Layer 2 R-Value (e.g. sheathing)**: The R-value of a second layer, like exterior sheathing.
- **Layer 3 R-Value (e.g. drywall)**: The R-value of interior finish material, like drywall (typically about R-0.45 for 1/2 in).

## The answer on the opening values

Worked exactly as the page works it, on the values each system opens on.

### Metric

| Result | Value |
|---|---|
| **Total assembly R-value** | 15.8 R-value |
| Sum of material layers | 14.95 R |
| Air film allowance | 0.85 R |

### US customary

| Result | Value |
|---|---|
| **Total assembly R-value** | 15.8 R-value |
| Sum of material layers | 14.95 R |
| Air film allowance | 0.85 R |

## How it is worked out

The working the page shows, in order: Sum of material layers; Air film allowance; then total assembly R-value.

The method, derived in full:

- [Thermal Resistance in Series](https://craftquantities.com/methodology/thermal-resistance-in-series/): Why R-values add but U-values do not, and why the assembly you build never performs like the assembly you specified.

What this calculation does not cover:

- Layers are summed straight through the insulated cavity. Studs, joists, plates, headers and rim areas conduct several times faster than the insulation between them and are not deducted here, so the real whole-wall or whole-ceiling figure is lower than this total. Run the Thermal Bridging Effective R-Value Calculator on the same wall to see by how much.
- The figures are imperial R-values in hr·ft²·°F/BTU, and so is the fixed R-0.85 air film allowance. Metric RSI values in m²K/W are about 5.68 times smaller, so entering those makes the film allowance alone roughly six times too generous. Convert before you type.
- The air film allowance is one fixed number written for a wall: still indoor air with sideways heat flow, and an outside face exposed to wind. It does not change for heat flowing up or down, for a surface facing a vented attic or an enclosed crawl space, or for a reflective low-emissivity face, all of which shift the film values.
- Product R-values are lab ratings for material at full thickness with no gaps. Batts compressed under wiring, voids at plates and corners, and loose fill that has settled all deliver less than the printed number, and nothing here downgrades the total for installation quality.
- R-value covers conduction only. It says nothing about air leakage, wind washing through the insulation, or moisture in the assembly, and this total is not a code compliance check: the required figure depends on climate zone and on which element you are building, and codes are frequently verified against a whole-assembly U-factor that includes the framing this sum leaves out.

## Sources

As the calculator cites them (sources checked 2026-09-02):

- Thermal resistances (R-values) in a layered assembly add directly: total R = sum of each layer's R-value
- A combined interior + exterior air film allowance of approximately R-0.85 is commonly included in total assembly R-value calculations

A code or standard has force only where a jurisdiction has adopted it, usually with local amendments; check what is in force with the authority where you build.

## Questions answered on the page

**What R-value do I need for my climate?**

It varies by climate zone and which part of the house (attic, wall, floor) — check your local building code or the U.S. Department of Energy's climate zone R-value recommendations for a specific target.

**Does an air gap have an R-value?**

A still air gap does add some resistance, but it's small and inconsistent (affected by air movement) — this calculator doesn't include a separate air-gap layer; add it to a material layer's value if you want to account for it roughly.

**Why do R-values simply add together?**

Thermal resistance in materials stacked in the direction of heat flow behaves like electrical resistors in series — the resistances (R-values) sum directly, unlike some other physical properties.

## Related calculators

- [Insulation Batt Calculator](https://craftquantities.com/calculators/insulation-efficiency/insulation-batt-calculator/)
- [Insulation R-Value by Climate Zone Calculator (IECC 2021 and NBC 2020)](https://craftquantities.com/calculators/insulation-efficiency/climate-zone-insulation-calculator/)

## Run it from a program

- REST: `GET https://api.craftquantities.com/v1/calculate/r-value-calculator` with each input as a query parameter, a length, area or volume with its unit; `https://api.craftquantities.com/v1/describe/r-value-calculator` lists the inputs.
- MCP: the `calculate` tool at https://api.craftquantities.com/mcp with `slug` `r-value-calculator`.
- Definition and test vectors: https://craftquantities.com/api/v1/calculators/r-value-calculator.json

---
Source: https://craftquantities.com/calculators/insulation-efficiency/r-value-calculator/
Craft Quantities: free to read, cite and link to; the pages are not licensed for republication. Quantities only: no prices, no design and no certification.