# Insulation Thickness for a Target U-Value Calculator (BS EN ISO 6946)

> The insulation thickness a target U-value needs, from the other layers and the product's conductivity, and the U-value a board you can buy reaches.

Page: https://craftquantities.com/calculators/insulation-efficiency/insulation-thickness-target-u-value-calculator/ (calculator). This is the page's Markdown copy; the HTML page is the canonical version.

Version 1.0.0, sources checked 2026-09-22, 5 published test vectors.

Insulation thickness needed: 4.23 in for Target U-Value 0.03 BTU/(hr·ft²·°F), Thermal Resistance of the Other Layers 2.84 hr·ft²·°F/BTU and Thermal Conductivity of the Insulation 0.15 BTU·in/hr·ft²·°F, the page's opening figures; on the metric page, 0.18 W/m²K, 0.5 m²K/W and 0.02 W/m·K give 107 mm. Sources are cited below.

## Inputs

A length, area or volume is entered with its unit. The page opens on the values below: a metric reader sees the metric column, a US customary reader the other.

| Input | id | Opens at (metric) | Opens at (US customary) | Accepts |
|---|---|---|---|---|
| Target U-Value | `targetU` | 0.18 W/m²K | 0.0316998 BTU/(hr·ft²·°F) | w_m2k, btu_h_ft2_f; range 0.05–3 W/m²K |
| Element and Direction of Heat Flow | `heatFlow` | Wall — heat flows sideways | Wall — heat flows sideways | `horizontal`, `upward`, `downward` |
| What the Outside of the Construction Faces | `outerFace` | The outside air | The outside air | `outside`, `ventilated` |
| Thermal Resistance of the Other Layers | `otherLayers` | 0.5 m²K/W | 2.83913 hr·ft²·°F/BTU | m2k_w, h_ft2_f_btu; range 0–20 m²K/W |
| Thermal Conductivity of the Insulation (λ) | `conductivity` | 0.022 W/m·K | 0.152536 BTU·in/hr·ft²·°F | w_mk, btu_in_h_ft2_f; range 0.012–0.2 W/m·K |
| A Board Thickness to Check (0 to skip) | `boardThickness` | 0 mm | 0 in | mm, cm, m, in, ft, yd; range 0–0.6 m |

- **Target U-Value**: The U-value the element has to reach, from the regulation or specification for this job.
- **Element and Direction of Heat Flow**: Sets the internal surface resistance, which depends on which way the heat is flowing.
- **What the Outside of the Construction Faces**: A well-ventilated cavity counts for nothing, and nor does anything outside it.
- **Thermal Resistance of the Other Layers**: Everything in the construction except the new insulation and the two surface films, added together.
- **Thermal Conductivity of the Insulation (λ)**: The declared conductivity on the product's certificate, at the thickness you are buying.
- **A Board Thickness to Check (0 to skip)**: The thickness you can actually buy, to see the U-value it reaches with the rest of the construction.

## The answer on the opening values

Worked exactly as the page works it, on the values each system opens on.

### Metric

| Result | Value |
|---|---|
| **Insulation thickness needed** | 107 mm |
| Total resistance the target asks for (1 ÷ U) | 5.56 m²K/W |
| Internal surface resistance | 0.13 m²K/W |
| External surface resistance | 0.04 m²K/W |
| The other layers | 0.5 m²K/W |
| Resistance the insulation has to supply | 4.89 m²K/W |

### US customary

| Result | Value |
|---|---|
| **Insulation thickness needed** | 4.23 in |
| Total resistance the target asks for (1 ÷ U) | 31.55 hr·ft²·°F/BTU |
| Internal surface resistance | 0.74 hr·ft²·°F/BTU |
| External surface resistance | 0.23 hr·ft²·°F/BTU |
| The other layers | 2.84 hr·ft²·°F/BTU |
| Resistance the insulation has to supply | 27.74 hr·ft²·°F/BTU |

## How it is worked out

Thickness = (1 ÷ U − the two surface resistances − the other layers) × λ: the layer sum of BS EN ISO 6946 run backwards.

The working the page shows, in order: Total resistance the target asks for (1 ÷ U); Internal surface resistance; External surface resistance; The other layers; Resistance the insulation has to supply; then insulation thickness needed.

The method, derived in full:

- [Thermal Resistance in Series](https://craftquantities.com/methodology/thermal-resistance-in-series/): Why R-values add but U-values do not, and why the assembly you build never performs like the assembly you specified.

What this calculation does not cover:

- A layer bridged by timber or steel — insulation between rafters, studs or joists — is worth less than its full resistance, because the framing carries heat around it. BS EN ISO 6946 averages the two paths with its upper and lower limit method; enter the bridged layer's reduced figure, or use the thermal bridging calculator for it.
- A floor on the ground loses heat in a way that depends on its exposed perimeter as well as its layers, calculated to BS EN ISO 13370. This page gives the thickness the layers need, not the ground floor's U-value.
- The corrections of BS EN ISO 6946 Annex F — for air gaps in the insulation layer, mechanical fixings through it and rain on an inverted roof — are not applied.
- The target comes from the regulation or specification for the job, and the conductivity from the product's own certificate; neither is supplied here.

## Sources

As the calculator cites them (sources checked 2026-09-22):

- BS EN ISO 6946:2017, Building components and building elements — Thermal resistance and thermal transmittance: U = 1 ÷ (Rsi + ΣR + Rse), each layer's resistance its thickness ÷ λ; surface resistances in 6.8, a well-ventilated air layer in 6.9.4
- Surface resistances as tabulated for heat flow upwards 0.10, horizontal 0.13 and downwards 0.17 m²K/W, and 0.04 m²K/W outside (BS EN ISO 13788:2012 Table 2 and 4.4.1 carry the same values)
- Declared thermal conductivity λD from the product standards — BS EN 13165 (PIR and PUR), BS EN 13163 (EPS), BS EN 13162 (mineral wool)

A code or standard has force only where a jurisdiction has adopted it, usually with local amendments; check what is in force with the authority where you build.

## Questions answered on the page

**Why run the target backwards rather than try thicknesses?**

Because consent is granted against a U-value and merchants sell millimetres. The total resistance the target asks for is 1 ÷ U; take away the two surface resistances and everything else in the construction, and what is left is the insulation's share. Multiply it by the insulation's conductivity and that is the thickness. Then check the stock size above it with the board box.

**Why does PIR come out so much thinner than EPS?**

Because the thickness is the resistance times the conductivity, and PIR's declared conductivity is about 0.022 W/m·K against EPS's 0.038 (k-values of 0.15 and 0.26 BTU·in/hr·ft²·°F). The same resistance takes 1.73 times the thickness in EPS — 186 mm against 107 mm (7.3 in against 4.2 in) on the default wall — which matters most where every millimetre is headroom.

**What happens under a ventilated roof?**

The ventilated layer counts for nothing and nor does anything outside it: the tiles, the battens and the membrane drop out of the sum, and the outer surface resistance is taken as still air, equal to the inner one. Only the layers on the room side of the airway are entered.

**Can I use it for a U-value in BTU/hr·ft²·°F?**

Yes — the target, the resistances and the conductivity all follow the unit switch, so a US U-factor, R-values and a k-value can be typed as they are. The arithmetic is the same; only the units change.

## Related calculators

- [R-Value Calculator](https://craftquantities.com/calculators/insulation-efficiency/r-value-calculator/)
- [U-Value Metric to Imperial Converter (W/m²K to BTU/hr·ft²·°F)](https://craftquantities.com/calculators/insulation-efficiency/u-value-si-to-imperial-calculator/)
- [Thermal Bridging Effective R-Value Calculator](https://craftquantities.com/calculators/insulation-efficiency/thermal-bridging-calculator/)
- [Surface Temperature Factor (fRsi) Calculator (BS EN ISO 13788, BRE IP 1/06)](https://craftquantities.com/calculators/insulation-efficiency/surface-temperature-factor-frsi-calculator/)

## Run it from a program

- REST: `GET https://api.craftquantities.com/v1/calculate/insulation-thickness-target-u-value-calculator` with each input as a query parameter, a length, area or volume with its unit; `https://api.craftquantities.com/v1/describe/insulation-thickness-target-u-value-calculator` lists the inputs.
- MCP: the `calculate` tool at https://api.craftquantities.com/mcp with `slug` `insulation-thickness-target-u-value-calculator`.
- Definition and test vectors: https://craftquantities.com/api/v1/calculators/insulation-thickness-target-u-value-calculator.json

---
Source: https://craftquantities.com/calculators/insulation-efficiency/insulation-thickness-target-u-value-calculator/
Craft Quantities: free to read, cite and link to; the pages are not licensed for republication. Quantities only: no prices, no design and no certification.