# Insulation R-Value by Climate Zone Calculator (IECC 2021 and NBC 2020)

> Minimum insulation by the 2021 IECC for a US climate zone or the 2020 NBC for a Canadian one: ceiling, walls, floor, basement, slab and window figures.

Page: https://craftquantities.com/calculators/insulation-efficiency/climate-zone-insulation-calculator/ (calculator). This is the page's Markdown copy; the HTML page is the canonical version.

Version 1.0.0, sources checked 2026-10-05, 19 published test vectors.

## Inputs

A length, area or volume is entered with its unit. The page opens on the values below: a metric reader sees the metric column, a US customary reader the other.

| Input | id | Opens at (metric) | Opens at (US customary) | Accepts |
|---|---|---|---|---|
| Code and Climate Zone | `zone` | IECC 2021 (US): climate zone 5, and Marine 4 | IECC 2021 (US): climate zone 5, and Marine 4 | `iecc-1`, `iecc-2`, `iecc-3`, `iecc-4`, `iecc-5`, `iecc-6`, `iecc-78`, `nbc-4`, `nbc-4-hrv`, `nbc-5`, `nbc-5-hrv`, `nbc-6`, `nbc-6-hrv`, `nbc-7a`, `nbc-7a-hrv`, `nbc-7b`, `nbc-7b-hrv`, `nbc-8`, `nbc-8-hrv` |
| Part of the Building | `component` | Ceiling below an attic | Ceiling below an attic | `ceiling`, `roof`, `frameWall`, `massWall`, `floor`, `basementWall`, `crawlWall`, `slab`, `heatedSlab`, `slabFooting` |

- **Code and Climate Zone**: Your US climate zone under the 2021 IECC, or your Canadian heating-degree-day zone under the NBC 2020, with or without a heat-recovery ventilator. US and Canadian codes only: the UK's Approved Document L and Australia's NCC set their own figures, and the U-value calculators work in their terms.
- **Part of the Building**: The assembly whose minimum you want; the window and skylight figures for the zone come with every answer.

## The answer on the opening values

Worked exactly as the page works it, on the values each system opens on.

### Metric

| Result | Value |
|---|---|
| **Minimum the code tabulates** | 10.567 m²K/W |
| In R-value (hr·ft²·°F/BTU) | 60 hr·ft²·°F/BTU |
| In RSI (m²K/W) | 10.567 m²K/W |
| Whole-assembly U-factor, the other route | 0.136 W/m²K |
| Windows: U-factor at most, in this zone | 1.703 W/m²K |
| Skylights: U-factor at most, in this zone | 3.123 W/m²K |

### US customary

| Result | Value |
|---|---|
| **Minimum the code tabulates** | 60 hr·ft²·°F/BTU |
| In R-value (hr·ft²·°F/BTU) | 60 hr·ft²·°F/BTU |
| In RSI (m²K/W) | 10.567 m²K/W |
| Whole-assembly U-factor, the other route | 0.024 BTU/(hr·ft²·°F) |
| Windows: U-factor at most, in this zone | 0.3 BTU/(hr·ft²·°F) |
| Skylights: U-factor at most, in this zone | 0.55 BTU/(hr·ft²·°F) |

- Confidence: medium.

## How it is worked out

The 2021 IECC's own figures: the R-value table gives the insulation's rated R-value, and the U-factor table, the other route, the whole assembly's U-factor. A jurisdiction adopts an edition and amends it, so the code in force where you build sets the figure; the page states a minimum and certifies no wall or roof.

The working the page shows, in order: In R-value (hr·ft²·°F/BTU); In RSI (m²K/W); Whole-assembly U-factor, the other route; Windows: U-factor at most, in this zone; Skylights: U-factor at most, in this zone; then minimum the code tabulates.

The method, derived in full:

- [Thermal Resistance in Series](https://craftquantities.com/methodology/thermal-resistance-in-series/): Why R-values add but U-values do not, and why the assembly you build never performs like the assembly you specified.

What this calculation does not cover:

- A table's minimum, not a design. The prescriptive tables are one route among several: the IECC also allows a total UA trade-off and a performance path, and the NBC a trade-off, a performance path, its tiered paths and the national energy code for buildings, any of which can set different figures for the same building.
- Editions and amendments decide it. Many US states and cities are on another edition or have amended the IECC (Washington, California, Oregon and New York write their own), and each Canadian province or territory adopts the NBC with its own changes; the code adopted where you build governs.
- An IECC R-value is the insulation's own rating, in the cavity and continuous layers; framing, gaps and compression are not in it. The NBC's RSI is the whole assembly's effective value with the framing counted, which a wall of R-20 (RSI 3.52) batts does not reach; the page's thermal bridging and R-value calculators work an assembly's effective figure.
- The footnotes and the sections around the tables carry exceptions this page only names: ceilings without attics, eave heel heights, access hatches, mass walls, slab and crawl space details, steel framing, and fenestration in high or windborne-debris locations. The code text is the authority, not this summary.
- UK and Australian readers: the UK's Approved Document L sets U-values for each element rather than climate zones, and Australia's National Construction Code sets its own zone figures; neither is tabulated here, and the page's U-value calculators work in their terms.

## Sources

As the calculator cites them (sources checked 2026-10-05):

- International Code Council, IECC Residential Committee Action Report on the 2021 public input changes, updated 26 July 2022, proposal REPI-33-21: the 2021 IECC Table R402.1.2 (maximum assembly U-factors and fenestration requirements) and Table R402.1.3 (insulation minimum R-values and fenestration requirements by component) with their footnotes, printed as the base text being revised. The 2021 text is everything not underlined: in the ceiling cells the struck figures (R-49 and R-60; U-0.026 and U-0.024) are the 2021 text, and the underlined ones (R-38 and R-49; U-0.030 and U-0.026) are the proposal's <https://www.iccsafe.org/wp-content/uploads/IECC-RES-CAR-update-72622.pdf>
- Cross-checks: Washington County, Maryland, 2021 IECC Residential Energy Efficiency Code compliance form (climate zone 4 except Marine, both tables); US DOE, final determination technical support document for the 2021 IECC (changes from 2018: ceilings R-49 and R-60, zone 4 and 5 walls 20+5ci, slabs R-10 at 2 ft and 4 ft, fenestration 0.30); Maine 16-642 CMR ch. 6 §6 (amending the zone 6 and 7-8 wall entries); Delaware DNREC, 2021 IECC residential changes (R402.2.1: R-38 for R-49 and R-49 for R-60 where uncompressed insulation extends over the top plates at the eaves) <https://www.energycodes.gov/sites/default/files/2021-07/2021_IECC_Final_Determination_AnalysisTSD.pdf>
- Pacific Northwest National Laboratory (T. L. Gilbride et al.), Guide to Determining Climate Zone by County: Building America and IECC 2021 Updates (September 2022), the 2021 IECC climate zone of every US county <https://basc.pnnl.gov/library/guide-determining-climate-zone-county-building-america-and-iecc-2021-updates>
- National Research Council of Canada, National Building Code of Canada 2020, Division B: 9.36.1.2.(3) effective thermal resistance (RSI) as the inverse of an assembly's U-value; 9.36.1.3 compliance paths; Tables 9.36.2.6.-A and -B (above-ground opaque assemblies without and with a heat-recovery ventilator), 9.36.2.6.(3) the attic reduction near the eaves; Tables 9.36.2.7.-A and -B (fenestration, doors, skylights); Tables 9.36.2.8.-A and -B (below grade), 9.36.2.8.(3)–(9); Article 1.1.3.1 and Appendix C Table C-2 for degree-days

A code or standard has force only where a jurisdiction has adopted it, usually with local amendments; check what is in force with the authority where you build.

## Questions answered on the page

**What R-value does my attic need?**

Under the 2021 IECC's R-value table: R-30 (RSI 5.28) in climate zones 0 and 1, R-49 (RSI 8.63) in zones 2 and 3, and R-60 (RSI 10.57) in zones 4 to 8. Section R402.2.1 lets R-49 stand for R-60, and R-38 (RSI 6.69) for R-49, where that insulation reaches full height over the wall top plates at the eaves. In Canada the NBC 2020 asks a ceiling below an attic for an effective RSI of 6.91 (R-39.2) in zone 4 up to 10.43 (R-59.2) in zones 7A to 8, depending also on whether there is a heat-recovery ventilator.

**Why does the Canadian figure look lower than the US one for the same wall?**

Because they measure different things. The IECC's R-20 (RSI 3.52) wall is that much insulation alone; the studs, plates and headers that conduct heat around it are not counted. The NBC's RSI 3.08 (R-17.5) wall is the effective value of the whole assembly with its framing and air films, and a wall with R-20 (RSI 3.52) batts between studs usually comes out below that effective figure. Compare like with like: the IECC's U-factor table, which is for whole assemblies, is the closer match to the NBC.

**What does 'R-20 + 5ci' mean in the code table?**

Two layers: R-20 (RSI 3.52) of insulation between the studs, the cavity, and R-5 (RSI 0.88) of continuous insulation, ci, unbroken by framing, usually rigid board or mineral wool outside the sheathing. The table's footnote g says the first figure is the cavity and the second the continuous layer. The 2021 IECC lists four such ways to build a wall in zones 4 to 8, any one of which meets its R-value path.

**How do I find my climate zone?**

In the US, by county: the IECC's Figure R301.1 and Table R301.1, and Pacific Northwest National Laboratory's county guide for the 2021 IECC, which also lists the counties whose zone changed from the 2018 map. In Canada, by heating degree-days below 18 °C (64.4 °F): the National Building Code's Appendix C lists them for over 600 places, and the authority having jurisdiction may set its own. Toronto's City Hall, at 3520, is zone 5; Ottawa's, at 4440, is zone 6.

**Is meeting the table the same as meeting the energy code?**

No, and the page does not say it is. The table is one prescriptive route; the building also has air sealing, ventilation, mechanical and other requirements, the code adopted locally may differ, and the inspector or authority decides. Use the figure to plan the insulation, and the code text and the local building department to confirm it.

## Related calculators

- [R-Value Calculator](https://craftquantities.com/calculators/insulation-efficiency/r-value-calculator/)
- [R-Value to RSI Calculator](https://craftquantities.com/calculators/insulation-efficiency/r-value-to-rsi-calculator/)
- [U-Value to R-Value Calculator](https://craftquantities.com/calculators/insulation-efficiency/u-value-to-r-value-calculator/)
- [Thermal Bridging Effective R-Value Calculator](https://craftquantities.com/calculators/insulation-efficiency/thermal-bridging-calculator/)
- [Attic Insulation Upgrade Calculator](https://craftquantities.com/calculators/insulation-efficiency/attic-insulation-upgrade-calculator/)
- [Insulation Thickness for a Target U-Value Calculator (BS EN ISO 6946)](https://craftquantities.com/calculators/insulation-efficiency/insulation-thickness-target-u-value-calculator/)

## Run it from a program

- REST: `GET https://api.craftquantities.com/v1/calculate/climate-zone-insulation-calculator` with each input as a query parameter, a length, area or volume with its unit; `https://api.craftquantities.com/v1/describe/climate-zone-insulation-calculator` lists the inputs.
- MCP: the `calculate` tool at https://api.craftquantities.com/mcp with `slug` `climate-zone-insulation-calculator`.
- Definition and test vectors: https://craftquantities.com/api/v1/calculators/climate-zone-insulation-calculator.json

---
Source: https://craftquantities.com/calculators/insulation-efficiency/climate-zone-insulation-calculator/
Craft Quantities: free to read, cite and link to; the pages are not licensed for republication. Quantities only: no prices, no design and no certification.