# Attic and Loft Ventilation Calculator (Intake, Exhaust and Vent Count)

> Net free vent area for an attic or cold loft by the IRC, NBC, BS 5250 or NCC, split between eaves intake and high exhaust, and the vents that provide it.

Page: https://craftquantities.com/calculators/insulation-efficiency/attic-ventilation-calculator/ (calculator). This is the page's Markdown copy; the HTML page is the canonical version.

Version 1.1.0, sources checked 2026-10-05, 12 published test vectors.

Net free vent area needed: 6.5 sq ft (net free area) for Attic or Loft Length 39 ft and Attic or Loft Width 25 ft, the page's opening figures; on the metric page, 12 m and 7.5 m give 0.6 m². Sources are cited below.

## Inputs

A length, area or volume is entered with its unit. The page opens on the values below: a metric reader sees the metric column, a US customary reader the other.

| Input | id | Opens at (metric) | Opens at (US customary) | Accepts |
|---|---|---|---|---|
| Attic or Loft Length (along the ridge) | `atticLength` | 12 m | 39 ft | mm, cm, m, in, ft, yd; range 0.01–60 m |
| Attic or Loft Width (the span, eaves to eaves) | `atticWidth` | 7.5 m | 25 ft | mm, cm, m, in, ft, yd; range 0.01–60 m |
| Rule | `hasVaporBarrier` | IRC R806.2: 1/150 of the attic floor (United States) | IRC R806.2: 1/150 of the attic floor (United States) | `no`, `yes`, `nbc`, `nbcLow`, `ukLow`, `ukMid`, `ukSteep`, `auLow`, `auMid`, `auSteep` |
| Share of the Vent Area High Up (%) | `exhaustShare` | 50 | 50 | range 0–100 |
| Intake Vent (eaves or soffit) | `intakeVent` | Marley 25 mm eaves vent, 25,000 mm² per metre | Lomanco 140 soffit vent, 88 sq in per 8 ft length | `soffit`, `custom` |
| Net Free Area of One Intake Vent | `intakeArea` | 25000 mm² | 88 in² | m2, ft2, mm2, in2; range 0.00001–1 m² |
| Exhaust Vent (ridge or upper) | `exhaustVent` | GAF Cobra RidgeRunner ridge vent, 26,458 mm² per metre | GAF Cobra RidgeRunner ridge vent, 12.5 sq in per foot | `ridge`, `custom` |
| Net Free Area of One Exhaust Vent | `exhaustArea` | 26458 mm² | 12.5 in² | m2, ft2, mm2, in2; range 0.00001–1 m² |

- **Attic or Loft Length (along the ridge)**: The length of the attic floor, measured along the ridge; the page takes each eave and the ridge to be this long.
- **Attic or Loft Width (the span, eaves to eaves)**: The width of the attic floor, wall plate to wall plate across the building.
- **Rule**: The rule the vent area comes from: the IRC's ratio, Canada's, or the UK's and Australia's openings along the eaves and ridge.
- **Share of the Vent Area High Up (%)**: The part of the total in vents near the ridge, in the upper portion R806.2 describes; the 1/300 exception needs 40 to 50%.
- **Intake Vent (eaves or soffit)**: The intake product, so the page can count it; the slot is a real product rated by its maker.
- **Net Free Area of One Intake Vent**: From the vent's label or data sheet: its net free area, after the louvres, mesh and insect screen.
- **Exhaust Vent (ridge or upper)**: The exhaust product high on the roof: a ridge vent, or individual roof vents.
- **Net Free Area of One Exhaust Vent**: From the label or data sheet: the net free area of one roof vent, or of one piece of a continuous ridge vent.

`exhaustShare` applies only when `hasVaporBarrier` is `yes`.
`intakeArea` applies only when `intakeVent` is `custom`.
`exhaustArea` applies only when `exhaustVent` is `custom`.

## The answer on the opening values

Worked exactly as the page works it, on the values each system opens on.

### Metric

| Result | Value |
|---|---|
| **Net free vent area needed** | 0.6 m² |
| Attic floor area | 90 m² |
| Net free area needed | 600,000 mm² |
| Intake, low on the roof (eaves or soffit) | 317,496 mm² |
| Exhaust, high on the roof (ridge or upper vents) | 300,000 mm² |
| Intake as a continuous gap along both eaves | 13.23 mm |
| Exhaust as a continuous gap along the ridge | 25 mm |
| Intake vent to fit | 13 m |
| Exhaust vent to fit | 12 m |
| High-level share of the total | 50 % |

### US customary

| Result | Value |
|---|---|
| **Net free vent area needed** | 6.5 sq ft (net free area) |
| Attic floor area | 975 sq ft |
| Net free area needed | 936 in² |
| Intake, low on the roof (eaves or soffit) | 475 in² |
| Exhaust, high on the roof (ridge or upper vents) | 468 in² |
| Intake as a continuous gap along both eaves | 0.51 in |
| Exhaust as a continuous gap along the ridge | 1 in |
| Intake vent to fit | 6 vents (8 ft) |
| Exhaust vent to fit | 38 ft |
| High-level share of the total | 50 % |

- Confidence: medium.

## How it is worked out

R806.2 of the 2021 IRC: 1/150 of the attic floor. The code sets no split at this ratio; the page divides it evenly between intake low on the roof and exhaust high up, and keeps the intake at least equal to the exhaust bought, as GAF's balanced-ventilation guidance asks.

The working the page shows, in order: Attic floor area; Net free area needed; Intake, low on the roof (eaves or soffit); Exhaust, high on the roof (ridge or upper vents); Intake as a continuous gap along both eaves; Exhaust as a continuous gap along the ridge; Intake vent to fit; Exhaust vent to fit; High-level share of the total; then net free vent area needed.

The method, derived in full:

- [Ventilation: Net Free Area, Air Change and the Openings That Deliver Them](https://craftquantities.com/methodology/ventilation-openings-and-air-change/): Why a wooden louvre delivers a quarter of the hole you cut and a metal one three-quarters, why intake and exhaust have to be balanced or the roof ventilates the house, and why doubling the pressure does not double the flow.

What this calculation does not cover:

- Net free area is a rating, not a hole size. The counts divide by the rating printed on the product after its louvres, mesh and screens, and assume every vent is open: intake vents painted over, blocked by insulation slumped into the eaves with no baffle, or fitted over solid sheathing count for nothing.
- The shape is a simple gable roof with the ridge along the length. A hip roof has longer eaves and a shorter ridge, a roof with dormers, valleys or a firewall is several vented spaces, and each compartment is worked on its own; the fit checks along the eaves and ridge then need doing by hand.
- The US exception's vapor-retarder condition in climate zones 6, 7 and 8 is taken on trust: nothing here knows the climate zone or whether a Class I or II retarder is in place and continuous. Where either is missing, the 1/300 figure is not available and the 1/150 one applies.
- UK openings are BS 5250's for a cold roof with a high-resistance underlay, as makers restate them, taking the stricter maker at the 35° and 10 m (32.8 ft) boundaries; a breathable underlay, a warm roof, a lean-to or mono-pitch roof, and roofs of buildings other than dwellings each have their own provisions, and the underlay's certificate governs a breathable one.
- Australian openings are Table 10.8.3's, which applies in climate zones 6, 7 and 8 only, applied along both eaves of a dual-pitched roof. The roof space's 20 mm (0.8 in) minimum height, the cathedral ceiling's extra eaves opening, the unsarked tiled roof that needs no openings, and the exemptions for concrete roofs, structural insulated panels and BAL-FZ are the reader's to check against the clause itself.
- This restates a ratio or an opening size; it is not a code check, a moisture assessment or a performance calculation. Air leaking up from the house is usually the bigger moisture source, ember-resistant vents are required in some wildfire areas, and the authority having jurisdiction or building control decides what applies to a given roof.

A professional must decide:

- Australian openings are Table 10.8.3's, which applies in climate zones 6, 7 and 8 only, applied along both eaves of a dual-pitched roof. The roof space's 20 mm (0.8 in) minimum height, the cathedral ceiling's extra eaves opening, the unsarked tiled roof that needs no openings, and the exemptions for concrete roofs, structural insulated panels and BAL-FZ are the reader's to check against the clause itself.
- This restates a ratio or an opening size; it is not a code check, a moisture assessment or a performance calculation. Air leaking up from the house is usually the bigger moisture source, ember-resistant vents are required in some wildfire areas, and the authority having jurisdiction or building control decides what applies to a given roof.

## Sources

As the calculator cites them (sources checked 2026-10-05):

- International Code Council, 2021 International Residential Code, as adopted without amendment in the Colorado Division of Fire Prevention and Control Residential Code 2021: R806.2, net free ventilating area 1/150 of the vented space; exception, 1/300 where both conditions are met: a Class I or II vapor retarder on the warm-in-winter side of the ceiling in climate zones 6, 7 and 8, and 40 to 50 percent of the required area in ventilators in the upper portion of the attic or rafter space <https://up.codes/s/minimum-vent-area>
- Residential Code of Ohio, Ohio Adm. Code 4101:8-8-01 (effective 1 July 2019), sections 806.1–806.3 on the 2018 IRC text: upper ventilators not more than 3 ft (914 mm) below the ridge or highest point, measured vertically; the balance in the bottom one-third of the attic space; installation lower where framing conflicts; not less than 1 in (25 mm) between insulation and roof sheathing (Ohio deletes the exception's vapor-retarder condition) <https://www.law.cornell.edu/regulations/ohio/Ohio-Admin-Code-4101-8-8-01>
- National Research Council of Canada, National Building Code of Canada 2020, Division B, 9.19.1.1–9.19.1.3: vent area not less than 1/300 of the insulated ceiling area, or 1/150 where the roof slope is less than 1 in 6 or the roof has roof joists; vents distributed uniformly on opposite sides, at least 25% at the top and at least 25% at the bottom of the space; 63 mm between insulation and sheathing
- Marley, 'How do I ventilate a cold roof?' (technical support guidance, citing BS 5250, Management of moisture in buildings): with a high-resistance underlay, 25 mm along the eaves for pitches of 15° or less, 10 mm for pitches above 15°, and 5 mm at high level where the pitch exceeds 35°, the span exceeds 10 m, or the roof is lean-to or mono-pitch; Wienerberger, 'Roof space ventilation' (2013): a continuous 10 mm gap gives 10,000 mm² per metre run, and the 5 mm high-level vent where a building is 10 metres wide or more or the pitch 35 degrees or above (the page takes this, the stricter reading at the boundaries). Approved Document C (2013) 6.10–6.11 refers roof condensation to BS 5250 <https://cm.marley.co.uk/support/ventilation-and-dry-fix/how-do-i-ventilate-a-cold-roof>
- Vent ratings and the balance rule: GAF Cobra RidgeRunner data sheet RESCB171 (2020), 12.5 sq in per lineal foot (26,458 mm² per lineal metre), exhaust never to exceed intake, and the chart 1,600 sq ft to 31 ft with 388 sq in of intake; Lomanco 140 soffit vent product specification (2012), 88 sq in per 8 ft unit; Marley Ventilated Dry Ridge System, 5 mm continuous <https://images.homedepot-static.com/catalog/pdfImages/f5/f54f679c-2cad-4c8e-9837-dfd36ad2bf3e.pdf>
- Marley, Universal 25mm Eaves Vent System: 25,000 mm² free area of ventilation per linear metre, for roof pitches of 12.5° to 55° (product page; Marley's NBS Source data, ventilation opening 25 000 mm²/m, 6000 mm packs; fixing instructions, December 2018, a continuous 25 mm free ventilation path, pack code 46351) <https://cm.marley.co.uk/accessories/25mm-eaves-vent-system>
- Australian Building Codes Board, National Construction Code 2022 (as adopted), Housing Provisions 10.8.3, ventilation of roof spaces: in climate zones 6, 7 and 8, Table 10.8.3, under 10° pitch 25,000 mm²/m at each of two opposing ends; 10° to under 15°, 25,000 mm²/m at the eaves and 5,000 mm²/m at high level; 15° to under 75°, 7,000 mm²/m at the eaves and 5,000 mm²/m at high level, plus 18,000 mm²/m at the eaves for a cathedral ceiling; areas per metre of the roof's longest horizontal dimension; high level within 900 mm below the ridge; not for concrete roofs, structural insulated panels or BAL-FZ. Applied along both eaves as the Australian Steel Institute's 'Ventilation in Steel Roofing' (VSR V27, 2024) works the table for a gable or hipped roof <https://ncc.abcb.gov.au/editions/ncc-2022/adopted/housing-provisions/10-health-and-amenity/part-108-condensation-management>

The site's pages for the documents these name:

- [International Residential Code](https://craftquantities.com/standards/icc/irc/)
- [Approved Documents to the Building Regulations (England)](https://craftquantities.com/standards/uk-gov/uk-approved-documents/)

A code or standard has force only where a jurisdiction has adopted it, usually with local amendments; check what is in force with the authority where you build.

## Questions answered on the page

**What does 'net free area' mean?**

The open area air can actually move through once a vent's louvres, mesh and screens are allowed for, which is always less than the size of the hole it fills. Makers print it on the label or data sheet: GAF rates its Cobra RidgeRunner at 12.5 sq in a lineal foot (26,458 mm² a metre), Lomanco its 140 soffit vent at 88 sq in (568 cm²) for each 8 ft (2.44 m) length, and UK eaves vents are often sold by the continuous gap they equal, 10 mm (0.39 in) being 10,000 mm² a metre (4.7 sq in a foot) and Marley's 25 mm (0.98 in) system 25,000 mm² a metre (11.8 sq in a foot).

**How should the vent area be split between soffit and ridge?**

Under the IRC's 1/300 exception, 40 to 50% must be high up, within 3 ft (914 mm) of the ridge, and the rest in the bottom third of the attic. Canada's NBC asks for at least a quarter at the top and a quarter at the bottom. Where the code leaves it open, makers such as GAF ask for a balanced system in which exhaust never exceeds intake, and the page splits it evenly. In the UK, BS 5250 sets the eaves and ridge openings directly rather than as a split.

**How many soffit vents and how much ridge vent does an attic need?**

Divide each share of the area by the product's rating. GAF's own chart works a 1,600 sq ft (149 m²) attic at 1/300: 5.33 sq ft (0.50 m²) in all, half of it high up, which is 31 ft (9.45 m) of RidgeRunner at 12.5 sq in a foot (26,458 mm² a metre), and then at least the same 388 sq in (2,500 cm²) low down. At Lomanco's 88 sq in (568 cm²) an 8 ft (2.44 m) length that is five lengths, 40 ft (12.2 m) of soffit vent.

**When can the IRC's 1/300 be used instead of 1/150?**

Only when both of R806.2's conditions hold: 40 to 50% of the area is in upper vents, and in climate zones 6, 7 and 8 a Class I or II vapor retarder is installed on the warm-in-winter side of the ceiling. Outside climate zones 6, 7 and 8, only the upper-vent condition applies. A roof that cannot put that share high up, a hip roof with a very short ridge for example, is held to 1/150.

**How is a UK loft ventilated?**

For a cold roof, insulation on the ceiling with a high-resistance underlay, BS 5250 asks for openings along both eaves equal to a continuous 25 mm (0.98 in) gap at a pitch of 15° or less and 10 mm (0.39 in) above that, plus 5 mm (0.20 in) at high level when the pitch is 35° or more, the span is 10 m (32.8 ft) or more, or the roof is a lean-to or mono-pitch. The makers who restate the standard differ by a hair at exactly 35° and 10 m, and the page takes the stricter. Approved Document C refers roof condensation to that standard. A breathable underlay changes the picture, and its certificate says what ventilation it needs.

**How is a roof space ventilated in Australia?**

Since NCC 2022, homes in climate zones 6, 7 and 8 need a roof space at least 20 mm (0.8 in) high above the insulation, ventilated by pitch through Table 10.8.3: for an ordinary pitch of 15° to under 75°, 7,000 mm² of opening for each metre of the roof's longest side at the eaves (3.3 sq in a foot) and 5,000 mm² (2.4 sq in a foot) within 900 mm (35.4 in) of the ridge; flatter roofs need 25,000 mm² (11.8 sq in a foot) at the eaves. An unsarked tiled roof breathes through its tiles and needs no openings. Elsewhere in Australia the clause asks for none.

## Related calculators

- [R-Value Calculator](https://craftquantities.com/calculators/insulation-efficiency/r-value-calculator/)
- [Ridge Vent Linear Footage Calculator](https://craftquantities.com/calculators/materials-quantities/ridge-vent-linear-footage-calculator/)
- [Soffit Panel Calculator](https://craftquantities.com/calculators/renovation-construction/soffit-panel-calculator/)
- [Attic Baffle Vent Calculator](https://craftquantities.com/calculators/insulation-efficiency/attic-baffle-vent-calculator/)
- [Attic Fan CFM Calculator](https://craftquantities.com/calculators/plumbing-hvac/attic-fan-cfm-calculator/)
- [Crawl Space and Subfloor Vent Calculator](https://craftquantities.com/calculators/materials-quantities/crawl-space-vent-calculator/)

## Run it from a program

- REST: `GET https://api.craftquantities.com/v1/calculate/attic-ventilation-calculator` with each input as a query parameter, a length, area or volume with its unit; `https://api.craftquantities.com/v1/describe/attic-ventilation-calculator` lists the inputs.
- MCP: the `calculate` tool at https://api.craftquantities.com/mcp with `slug` `attic-ventilation-calculator`.
- Definition and test vectors: https://craftquantities.com/api/v1/calculators/attic-ventilation-calculator.json

---
Source: https://craftquantities.com/calculators/insulation-efficiency/attic-ventilation-calculator/